background image

4. Product Performance

5. Protective Circuit Specification

The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized 
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, 
short circuit. Overall, the BMS helps to ensure safe and accurate running.

NO.

Items

1

-20°C

Testing Method

Criteria

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage and record charge 
capacity. Store the battery at various temperatures 
for 2h and discharge the battery with 0.33C to the 
cut-off voltage.

0°C

25°C

55°C

≥70%

≥80%

≥100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual 
capacity ≥80%

Internal resistance

≤15mΩ

50% battery SOC state frequency of 1 KHZ ac resistan-
ce tester.

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (0.33C)/CV (14.6V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 
charged capacity is no more than 80% of normal 
value. Accumulated times is defined as cycle life.

2

Cycle life (DOD%100)

≥2500 cycles

3

4

Recovery 
capacity ≥90%

Items

Over-charge protection for each cell

Specification

Content

3.80±0.03V

Over charge

Over-charge release for each cell

3.60±0.04V

Over-charge release method

Under the release voltage

Though

user can read the battery system information 

such as voltage, current, SOC, temperature… 
and so on. 

Communication 
Function

Bluetooth

5

03

www.upowerbatteries.com

NA

-12Li300BL

** Siguiendo la normativa estricta de la industria naval en materias de interconexión eléctrica y salud