![Uponor Smatrix Base Pro Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/uponor/smatrix-base-pro/smatrix-base-pro_quick-manual_1060937007.webp)
3 s
3 s
04
T-149
T-148
T-146
10
11.1
SI0000396
X-147
T-149
T-149
T-148
T-146
T-148
T-146
11
11.3
11.5
11.2
11.2
11.4
11.4
1 2 3 4
ON
DIP
T-148
T-146
T-143
T-143
T-149
T-143
T-145
T-149
T-148
T-146
9
9.3
9.1
9.1
9.2
9.4
9.2
Note
The general handling of thermostats in this manual is
also valid for Uponor Smatrix Base Pro X-148 Modbus
RTU.
1―11 Connect the components
1.
Attach the full assembly, or parts of it, to the wall either with a
DIN rail or by using wall screws and plugs.
2.
Connect the actuators.
3.
Connect a thermostat communication cable to the controller,
slave module, and/or the optional star module. Note: Daisy chain
bus topology is recommended.
See section
Communications protocol, Page 10
for more
information.
4.
Connect a thermostat communication cable to the thermostat/
timer.
5.
Connect a system bus communication cable in between
controllers and route one cable to the interface. Note: Daisy
chain bus topology is recommended.
See section
Communications protocol, Page 10
for more
information.
6.
Connect a system bus communication cable (6.1) and a power
cable (6.2) to the interface.
7.
Check that all wiring is complete and correct:
•
Actuators
•
Heating/cooling switch
•
Circulation pump
8.
Ensure that the 230 V AC compartment of the controller is
closed and the fixing screw is tightened.
9.
Connect optional external sensor (compatible thermostats only)
and set the DIP switch (public thermostat T-143 only).
Function
Switch
Standard room thermostat
1 2 3 4
ON DIP
Standard room thermostat together with a floor
temperature sensor
1 2 3 4
ON DIP
Standard room thermostat, or system device, together
with an outdoor temperature sensor
1 2 3 4
ON DIP
System device together with a supply temperature
sensor for heating/cooling switch over function
1 2 3 4
ON DIP
System device where the sensor input is used for
Comfort/ECO switch over function **
1 2 3 4
ON DIP
Remote sensor
1 2 3 4
ON DIP
* The thermostat can only be registered as a system device to a
Base PRO system with multiple controllers, if it is registered to
the master controller.
** Closed = ECO
Uponor Smatrix Base PRO
|
Quick guide
|
7
EN
Содержание Smatrix Base Pro
Страница 22: ...22 Uponor Smatrix Base PRO Stru n pr vodce CZ...
Страница 32: ...32 Uponor Smatrix Base PRO Kurzanleitung DE...
Страница 42: ...42 Uponor Smatrix Base PRO Lynguide DK...
Страница 52: ...52 Uponor Smatrix Base PRO Kiirjuhend EE...
Страница 62: ...62 Uponor Smatrix Base PRO Gu a r pida ES...
Страница 72: ...72 Uponor Smatrix Base PRO Pikaopas FI...
Страница 82: ...82 Uponor Smatrix Base PRO Guide de r f rence rapide FR...
Страница 92: ...92 Uponor Smatrix Base PRO Brzi vodi HR...
Страница 112: ...112 Uponor Smatrix Base PRO Guida rapida IT...
Страница 122: ...122 Uponor Smatrix Base PRO Trumpa instrukcija LT...
Страница 132: ...132 Uponor Smatrix Base PRO s instrukcija LV...
Страница 142: ...142 Uponor Smatrix Base PRO Snelgids NL...
Страница 152: ...152 Uponor Smatrix Base PRO Hurtigveiledning NO...
Страница 162: ...162 Uponor Smatrix Base PRO Kr tki przewodnik PL...
Страница 187: ...Base PRO 10 230 11 04 RT Uponor Smatrix Base PRO 187 RU...
Страница 190: ...3 4 1 1 2 1 3 4 5 3 5 1 1 2 10 3 6 1 2 3 4 3 7 3 8 KNX 190 Uponor Smatrix Base PRO RU...
Страница 192: ...X 147 X 148 0 5 2 5 0 2 1 5 EN 60730 1 1 EN 60730 2 1 2 1 EN 60730 2 9 2 9 192 Uponor Smatrix Base PRO RU...
Страница 202: ...202 Uponor Smatrix Base PRO Snabbguide SE...
Страница 212: ...212 Uponor Smatrix Base PRO Hitri vodi SI...
Страница 222: ...222 Uponor Smatrix Base PRO Stru n n vod SK...
Страница 223: ...Uponor Smatrix Base PRO Quick guide 223...