You can enter the programming mode with 2 seconds push on the button.
The programming menu structure is described on the follow page. Mind
that once you have entered the programming menu you can exit it at the
last item only. All programming settings are stored in a non-volatile
memory and remain stored even if the controller was disconnected from
the battery.
Programming your Solar Controller
The button switch has three push modes:
1
)
Short push
Shorter than 1 seconds
2
)
Long push
2 to 8 seconds
3
)
Lock push
8 seconds or longer
By pushing the button for 8 sec in normal operation mode the
programming lock-out is activated to prevent any accidental settings
change. Another 8 sec push releases the lock-out.
With a long push, you can enter the programming mode. The
programming menu structure is described in the back page. A wide arrow
means a long push (2s-8s), a narrow dotted line arrow means a short push
(<1sec).
Testing Function
During the daytime the testing function of SLAC-SL can help the user to
verify correct installation or for troubleshooting a system problem. Short
pushing the button will light up the lamp which is connected to the load
terminals. The lights will be on in the day for 3 minutes intervals. Within
3 minutes the lights can be turned off via pushing button. The lights can
turned on repeatedly with pushing button besides when the system is in
LVD (load disconnect/red LED on). In LVD this testing function is not
valid. If pressing the button cause a load disconnects (LVD) the light will
turn off.
Safety Features
PV terminals
Battery terminals
Load
terminals
Reverse
polarity
24V system: no
12V system: yes
Protected
Protected
Short circuit
Protected
Protected (with fuse
on battery) (3)
Protected
Over current
Protected
Protected
Switches off
with
a delay (3)
Reverse
charge
Protected
No effect
No effect
Over voltage
Max. 55V
Max. 55V
Switches off
with a
delay
Under voltage
No effect
No effect
Switches off
above
15.5/31.0 V
Over
temperature
When over temperature occurs, the controller will
reduce the charging current. If the temperature of
controller reaches a high level, the load will
automatically be switched off.
(1) Controller can protect itself, but load might be damaged.
(2) We strongly recommend that add a fuse between battery and controller.
The battery may be permanent damaged when short circuit occurs.
(3) > 200% rated current: Load will be switched off with 3s delay.
Warning: Two or more error conditions at the same time may cause
damage to the controller. Always remove the present fault condition
before next operation
SLAC-SL Technical Characteristics
Model
SLAC-SL
5A
10A
20A
Max. charge/load current
5A
10A
20A
Rated System voltage
12V/24V auto recognition
Main charge
14.4V/28.8 V (25 °C), 30 min. (daily)
Boost charge
14.4/28.8 V (25 °C), 2 h Activation:
battery voltage < 12.3/24.6 V
Equalization voltage
14.8/29.6V(25 °C)
Float charge
13.8/27.6 V (25 °C)
Deep discharge protection,
Cut-off voltage
11 – 12 V/22 – 24 V
Reconnect level
12.8/25.6V
Under voltage protection
10.8/21.6V
Overvoltage protection
15.5/31.0 V
Self consumption
4mA-5mA
(
12V
)
6mA-8mA
(
24V
)
Max. panel voltage
50V
Temperature compensation
-4mV/Cell*K
Grounding
Positive grounding
Battery type
Lead acid (GEL, AGM, flooded)
Evening hours
0 – 12 h
Ambient temperature
-40°C-+60°C
Dimensions
50mm*56.6mm*20mm
Wire Length/size
150mm/2.5m²
Ambient temperature
-40°C-+60°C
IP grade
IP67
Max. altitude
4000m
Weight
130g