Technopel Compact Pellet Boiler Installation and User’s Manual
WARNING
Please do not use sharp and cutting tools to avoid damaging the pellet boiler while
unpacking
WARNING
Please avoid any crush injuries to hands and feet during transportation, installation, and
assembly.
SELECTION OF INSTALLATION PLACE
Installation
The installation place of the product must have sufficient free space for assembly, maintenance and
operation of the boiler.
The gearbox and the burner (to which the spiral is connected) must be placed at a sufficient distance
from the wall for service requirements. Please follow the instructions of “Dimensions of Installation
Place” in that stage.
In addition, there should be sufficient fresh air circulation, the chimney design model should meet
the stack draught requirements. The chimney construction criteria and relevant regulations in this
manual must be followed. The pellet boiler should never be installed in open areas, balconies, living
areas (kitchen, living room, bathroom, bedroom), or in places where explosive and easily flammable
materials are present.
The boiler room door must not open directly to the escape ladder or the general use ladder. It should
open to safeway hall. Doors opening from the boiler room to the building must have at least 10 cm
height from the floor. If the boiler room can be illuminated naturally, please make sure that the
lighting openings do not overlap with other windows of the building. System that does not dazzle but
illuminates the apartment well should be installed when there is no natural illumination. Boiler room
main switch and panels will be placed around the entrance door and should be of leakproof type.
There must be at least one 6 kg multiple purposes dry chemical powder type fire extinguisher in the
boiler room. The rupture surface should be designed if natural gas or liquid fuel boilers use in the
same boiler room.
The area should be connected directly to the outdoors and have vents that allow fresh air to enter.
One of the grates should be 40 cm below the ceiling of the boiler room and the other 50 cm above
the floor. These grids should always be open. The lower part should be at least 40x40 cm and the
upper part should be at least 30x30 cm. Pets should not be fed in the central heating area (boiler
room), they may be affected by smoke. Food and beverages should not be stored in this area.
All electrical and water systems must be installed by the plumbers of authorized technical services.
Installation must be done by the plumbers in order to comply with all legal and technical regulations.