INSAUBH1017
4
CAUTION – HIGH TEMPERATURE; RISK OF FIRE. KEEP
ELECTRICAL CORDS, DRAPERY, FURNISHINGS, AND OTHER
COMBUSTIBLES AT LEAST 3 FEET FROM THE FRONT OF THE
HEATER AND AWAY FROM THE SIDE AND REAR.
TO REDUCE THE RISK OF FIRE, DO NOT STORE OR USE
GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN
-
ITY OF THE HEATER. DO NOT MOUNT IN CONTACT WITH COMBUSTIBLE
MATERIAL. DO NOT MOUNT IN CLOSE PROXIMITY TO ANOTHER UNIT.
-
The unit must be secured to a wall, 12 in away from the floor and adjacent
walls (Fig.1). A minimum distance of 24 in from the floor to the bottom of the
unit must be respected when the towel holder is installed.
-
THE UNIT CANNOT BE COVERED OR HIDDEN BY A DOOR.
-
Drill three holes with a diameter slightly smaller than the one for the plastic
pins provided.
- Insert the pins.
-
Insert the two top screws provided, leaving a gap of 5/16 in between the
screw head and the wall (Fig.2).
-
Hang the unit on the two installed screws while holding it securely in your
hands;
CAUTION! BEFORE LETTING GO OF THE UNIT, CHECK THAT IT
IS SECURELY HUNG ON THE TWO SCREWS.
- Secure the unit with the third screw at the bottom (Fig.2).
-
Figure 3 on the right indicates the airflow generated by the heater. This air
corridor must remain clear in order to allow good air circulation and to ensure
that the unit operates efficiently.
- Leave at least 12 inches in front of the unit.
-
Do not install the heater below an electrical outlet.
INSTALLATION
FIGURE 1
12"
2
2
2
Minimum
12"
Minimum
12"
Minimum
WALL
WALL
FLOOR
FIGURE 3
12"
12"
AIR
INLET
AIR
OUTLET
INSTALLATION
N.B. Cut off power supply at circuit breaker/fuse before proceeding to the instal
-
lation and wiring connections.This product must be connected by a certified
electrician, according to the electrical and building codes effective in your re-
gion. Consult the wiring plan found on the unit.
- Make the electrical connections inside the junction box located at the back
of the unit (Fig.4).
- Installation of this product must be made in accordance with all national and
local building codes.
- The electrical connections must be made with a 12-gauge 2-conductor wire.
- This unit is double insulated. Because of the insulation feature, it does not
need to be grounded.
ELECTRICAL CONNECTION
FIGURE 4
JUNCTION
BOX
FIGURE 2
6"
1
4