background image

INSAUBH1017

4

CAUTION  –  HIGH  TEMPERATURE;  RISK  OF  FIRE.  KEEP 

ELECTRICAL CORDS, DRAPERY, FURNISHINGS, AND OTHER 

COMBUSTIBLES AT LEAST 3 FEET FROM THE FRONT OF THE 

HEATER AND AWAY FROM THE SIDE AND REAR. 
TO REDUCE THE RISK OF FIRE, DO NOT STORE OR USE 

GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN

-

ITY OF THE HEATER. DO NOT MOUNT IN CONTACT WITH COMBUSTIBLE 

MATERIAL. DO NOT MOUNT IN CLOSE PROXIMITY TO ANOTHER UNIT.

 -

The unit must be secured to a wall, 12 in away from the floor and adjacent 

walls (Fig.1). A minimum distance of 24 in from the floor to the bottom of the 

unit must be respected when the towel holder is installed.

 -

THE UNIT CANNOT BE COVERED OR HIDDEN BY A DOOR.

 -

Drill three holes with a diameter slightly smaller than the one for the plastic 

pins provided.

 - Insert the pins.
 -

Insert  the  two  top  screws  provided,  leaving  a  gap  of  5/16  in  between  the 

screw head and the wall (Fig.2).

 -

Hang the unit on the two installed screws while holding it securely in your 

hands; 

CAUTION! BEFORE LETTING GO OF THE UNIT, CHECK THAT IT 

IS SECURELY HUNG ON THE TWO SCREWS.

 - Secure the unit with the third screw at the bottom (Fig.2).
 -

Figure 3 on the right indicates the airflow generated by the heater. This air 

corridor must remain clear in order to allow good air circulation and to ensure 

that the unit operates efficiently. 

 - Leave at least 12 inches in front of the unit.
 -

Do not install the heater below an electrical outlet.

INSTALLATION

FIGURE 1

12"

2

2

2

Minimum

12"

Minimum

12"

Minimum

WALL

WALL

FLOOR

FIGURE 3

12"

12" 

AIR 

INLET

AIR 

OUTLET

INSTALLATION

N.B. Cut off power supply at circuit breaker/fuse before proceeding to the instal

-

lation  and  wiring  connections.This  product  must  be  connected  by  a  certified 

electrician, according to the electrical and building codes effective in your re-

gion. Consult the wiring plan found on the unit.

 - Make the electrical connections inside the junction box located at the back 

of the unit (Fig.4).

 - Installation of this product must be made in accordance with all national and 

local building codes.

 - The electrical connections must be made with a 12-gauge 2-conductor wire.
 - This unit is double insulated. Because of the insulation feature, it does not 

need to be grounded.

ELECTRICAL CONNECTION

FIGURE 4

JUNCTION 

BOX

FIGURE 2

  

6"

 

  1

5/16

Содержание AUBH1802

Страница 1: ...T INCLUDED AUBH1802 S Y S T È M E Q U A L I T É C ERTIFIÉ REGISTERED Q U A L I T Y S Y S T E M UNIWATT is a line of products manufactured by STELPRO For more information please contact customer service USER S GUIDE This unit complies with CSA and UL standards ...

Страница 2: ...ts When cutting or drilling into a wall do not damage electrical wiring and other hidden utilities When starting up the unit for the first time or after a long period it is normal that it produces some temporary odours and whitish smoke Because this unit is hot when in use it may pose risks even in normal operation Therefore be careful and responsible when using it To avoid burns do not let bare s...

Страница 3: ...s unit within arm s reach while in the shower the bathtub or near a sink Position the unit so the plug is easy to reach Never secure the unit to walls made of syn thetic materials The fan heater must be wall mounted in a verti cal position only SPECIFICATIONS TECHNICAL DRAWINGS FORCED AIR HEATER VOLTS 240 208 V WATTS 1800 1350 W AMPS 8 3 6 49 A WEIGHT 6 2 LB DEPTH 4 7 8 WIDTH 11 9 16 HEIGHT 16 3 1...

Страница 4: ... IS SECURELY HUNG ON THE TWO SCREWS Secure the unit with the third screw at the bottom Fig 2 Figure 3 on the right indicates the airflow generated by the heater This air corridor must remain clear in order to allow good air circulation and to ensure that the unit operates efficiently Leave at least 12 inches in front of the unit Do not install the heater below an electrical outlet INSTALLATION FIG...

Страница 5: ...ve but the warning lamp is on PROCEDURES TO BE FOLLOWED Turn off the fan heater and let it cool for about 15 20 minutes It is imperative to set the thermostat and the timer to the OFF position in order to re start it Check if the dust filter is blocked and if so clean and reinstall it Turn the fan heater on again and check for proper operation If you cannot get your unit to work return it to the o...

Страница 6: ...es shutdowns slowdowns or for other types of economic loss or for claims of a dealer s customers or any third party for such damages Stelpro specifically disclaims all consequential incidental and contingent damages whatsoever This warranty does not cover any damages or failures resulting from 1 a faulty installation or improper storage 2 an abusive or abnormal use lack of maintenance improper mai...

Отзывы: