5
Connecting the room loop cable
Pull out the loop cable (0.75mm²) and circle the listening area. Attach the cable at floor
level or ceiling height (about 2.4m / 8ft). Included with the room loop you will find 50 clips
for fastening of the loop cable on the baseboard. Other means of fastening the cable may
be used as well. Connect the ends of the cable to the spring clip terminal which is the left
of the two connectors marked "Loop" at the amplifier's rear panel.
Mains power connection
First connect the power adaptor to the socket marked
-
+
on the amplifier. Then
connect the adaptor to the power outlet.
Settings
Univox® AutoLoop 2.0 is fully automatic. No settings are needed. If you experience the
sound level in the loop being too high, you can lower the level in two steps by using the
level control marked at the bottom of the product. Default setting is +3dB.
Trouble shooting
If the loop amplifier does not perform satisfactory, check the following:
• First make sure that your hearing instrument is in T-position and that mains power is
connected to the loop amplifier.
• Is the “Active indicator” lit? If not, is the audio source connected and transmitting
a signal? If the audio source is connected and transmitting a signal and the “active
indicator” is still not lit, the amplifier is not working properly and you may proceed to
the Service section of this manual.
• If the “Active indicator” is lit, but you still can not receive a signal in your hearing
instrument, the loop pad/sofa loop/room loop is either not connected or faulty. Make
sure that it is connected properly.
C