RDRE
- electric version - gas version - Page 11
ROOM
The unit must be placed in a well-ventilated location, if possible under an exhaust hood to ensure rapid removal
of cooking vapours. Comply with requirements on free cross-section for drawing combustion air and for the
removal of any gas leaks.
The temperature in the place of installation must not exceed values of less than + 5° C or more than + 40° C. The
air humidity must be within the range of 40% to 75%. Conditions other than these may have a negative effect on
the unit's operation.
The oven must be levelled.
This can be checked wither with a spirit level or by setting a pan on top that has a small amount of water in it.
The backs and sides must be 10 cm from other appliances and flammable walls. If the distance is less or the
position is next to other units that give off heat (e.g. fryers), appropriate measures must be taken such as placing
protection against radiance
The manufacturer suggests a distance of 50 cm to allow for cleaning and service.
Make sure the openings of the unit are not obstructed or covered!
Strict compliance with fire prevention measures must be ensured