The UNIVEX slicer is designed to meet the cook's demand for an efficient, sturdy slicer. The 

UNIVEX slicer will give unfailing performance over a period of years, when operated and 

maintained according to instructions contained herein.

START/STOP SWITCH

The slicer is started by pushing the ON/OFF switch (Overview [1]). A indicator light (Overview [1]) is 

provided to indicate when the slicer is turned on.

AUTOMATIC MODE:

Be sure to set your slice thickness by turning the Slice Adjust Knob (Overview [12]) first before 

setting the slicer to automatic. To switch the slicer to automatic mode, simply turn the Automatic 

Selector Knob (Overview [13]) from Manual to Auto then press the Start Switch. The slicer will turn 

on and the carriage will begin moving back and forth. Simply turn the Automatic Selector Knob 

back to Manual to end the automatic feature or shut the slicer off.   

SLICE ADJUSTMENT

Warning

: Dial-type knob adjustment (Overview [12]) allows for slice thickness ranging

from paper thin up to .5". Dial graduations allow you to precisely set up specific slice thickness 

for various needs. Please note that the numbers labeled on the slice adjustment knob are for 

reference only and do not indicate any specific unit of measure. When not in use, always return knob

back to its fully closed position (beyond "0") so that the knife edge is not exposed.

POSITIVE HOLD CARRIAGE

Caution:

 A last slice gravity feed grip (Overview [3]) is provided which can be locked out

of the way when not required. Do not use this last slice device to work the carriage back and forth. 

Use only the carriage arm handle (Overview [9]). Always make sure the carriage is 

positively secured to the slicer by checking to see that the carriage arm knob (Overview [11]) 

is fully tightened.

PROTECTIVE GUARD

Warning:

 The protective guard (Overview [5]) covers the knife edge completely except at

the forward edge where slicing will be performed. This forward edge is covered by the edge of the 

fence, but only when the slice adjustment is completely closed.The knife guard 

(Overview [6]) can be removed for cleaning by unscrewing the knife guard knob 

( Refer to p.6 Figure 2 [2]). For safety, keep the knife guard on at all times except when cleaning. 

Never operate the slicer with the knife guard removed.

OPERATION INSTRUCTIONS

Page 5

Содержание 6612S

Страница 1: ...cer Operators Manual 05 2012 ED1 Persons under the age of 18 are not permitted to operate or have accessibility to operate this equipment per U S Dept Of Labor employment standards administration fact sheet No ESA91 3 ...

Страница 2: ...L BE INVLOVED WITH YOUR NEW UNIVEX SLICER MUST READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE THIS SLICER WE APPRECIATE YOUR COOPERATION AND YOUR BUSINESS SHOULD THERE BE A QUESTION OR IF WE CAN BE OF FURTHER ASSISTANCE PLEASE CALL US 1 800 258 6358 ATTENTION Page 1 ...

Страница 3: ...leaning Instructions p 6 7 7 Sanitizing Instructions p 8 9 Lubrication Instructions p 10 10 Inspection of Seals p 11 11 Slicer Wiring Diagram p 12 12 Warranty Information p 13 a Inspection b Installation c Important Safety Warnings a Start Stop Switch b Automatic Mode c Slice Adjustment d Positive Hold Carriage e Protective Guard 8 Sharpening Instructions p 9 Page 2 ...

Страница 4: ...Fence 3 Last Slice Device 4 Sharpener Assembly 5 Protective Guard 6 Knife Guard 8 Carriage 9 Carriage Arm Handle 10 Carriage Arm 11 Carriage Arm Knob 12 Slice Adjustment Knob 7 Adjustment Spacer 13 Automatic Manual Selector Knob Overview 1 2 3 4 5 6 7 8 9 10 11 12 13 Page 3 ...

Страница 5: ...ction This height is considered optimum when the carriage handle Overview 9 of the slicer is at approximately the height of the operator s elbow when standing Important Warning Caution Before making electrical connections CHECK the specifications on the nameplate to make sure that they agree with those on your electrical service A grounding type three terminal plug is provided for safety If you do...

Страница 6: ... up specific slice thickness for various needs Please note that the numbers labeled on the slice adjustment knob are for reference only and do not indicate any specific unit of measure When not in use always return knob back to its fully closed position beyond 0 so that the knife edge is not exposed POSITIVE HOLD CARRIAGE Caution A last slice gravity feed grip Overview 3 is provided which can be l...

Страница 7: ... now be removed and set aside c Carriage Arm Handle Loosen and remove the black handle Figure 1 7 and set aside d Carriage Arm Loosen the Carriage Arm Knob Figure 1 8 and set aside for cleaning Pull straight upwards on the Carriage and Arm Figure 1 9 and set the Carriage Assembly aside e Automatic Knob Remove screw located on front of Automatic Knob Figure 1 10 and set aside Pull knob forward to r...

Страница 8: ... water and a mild detergent 5 Wash the front and rear of the Knife Figure 6 2 and Knife Scraper Figure 7 with warm water and a mild detergent using extreme CAUTION around the blade Carefully remove the Knife Scraper as seen in Figure 8 and clean around the Knife s edge as shown in Figure 9 with warm water and a mild detergent applied to a soft cloth 6 Wash the Slicer Body Figure 6 3 with warm wate...

Страница 9: ...Section 4 501 114 Manual and Mechanical Warewashing Equipment Chemical Sanitation Temperature pH Concentration and Hardness of the FDA Food Code Chlorine Sanitizer Solution A chlorine sanitizer solution shall have a minimum temperature based on the concentration and pH of the solution listed in the following chart taken from section 4 501 114 of the FDA Food Code Minimum Concentration mg L 25 50 1...

Страница 10: ...Dial Figure 1 12 to beyond 0 This will ensure that the blade edge is not exposed to the operator 4 Move the carriage all the way to the start position closest to the operator 5 Loosen the sharpener locking pin Figure 10 1 then lift and rotate the sharpener 180 Lower the sharpener so that the blade is between the 2 stones and resecure with the sharpener locking pin 6 Turn the slicer on and push the...

Страница 11: ... in accordance with the lubrication instructions below During this lubrication sequence be sure to check for free operation and movement of related parts as well as for excessive wear and looseness of various parts Be sure to check all handles and knobs for tightness Never use any type of vegatable cooking spray or oil as lubrication as this will cause damage to your slicer Lubrication Instruction...

Страница 12: ...ve the slicer from service and contact an authorized service agency or Univex Full thorough inspections should be conducted not exceeding 6 month periods and is recommended to be performed by an authorized service agency However as the regular operator of the machine seals should be reviewed during normal daily cleaning and reported upon if found to be worn Refer to the below figure 14 for seal lo...

Страница 13: ...Fan Capacitors Blade motor Start Stop Switch Carriage Motor 1 2 3 Carriage Interlock Switch L1 L2 GND Power In 6612S Wiring Diagram Page 12 ...

Страница 14: ...the hours of 8 00 a m and 5 00 p m local time Monday through Friday Univex will not cover overtime charges of any kind Please call the Univex Warranty Service Department at 800 258 6358 to report any warranty claims before arranging repair or attempting to return the unit to Univex Corporation Damages incurred in transit or incurred because of installation error accident alteration or misuse are n...

Отзывы: