There are three pigtail leads (black, white and yellow) coming from the AC QUICK
CONNECTOR. The proper wire connection is as follows:

WIRES FROM QUICK CONNECTOR

CONNECT TO

BLACK

"HOT" side of AC line

WHITE

"NEUTRAL" side of AC line

YELLOW

Interconnect wires of other units

For units that are used as single smoke alarms, do not connect the yellow wire to anything.
Insulate this wire (tape it) in place to make certain the yellow wire cannot contact any metal
parts.

Interconnected units can provide earlier warning of fire than stand-alone units, especially if a
fire starts in a remote area of the dwelling. If any unit in the series senses smoke, all units will
alarm. This smoke alarm may be interconnected with as many as 11 other UNIVERSAL model
smoke alarms and 6 other units which may be a combination of HD-130 Heat Alarms or RM-
100 Relay Modules for a total of not more than 18 interconnected devices.

The yellow wire is used only for multiple station operation with UNIVERSAL Models SS-785,
SS-790 AND SS-795 only. Connecting this yellow wire to any other circuits may result in
damage. When smoke alarms are interconnected, all units must be powered from a single AC
branch circuit. If local codes do not permit be sure the neutral wire is common to both phases.
The maximum wire run distance between the first and last smoke alarm in an interconnected
system is 1,000 feet. NOTE: Use standard household wire (18 gauge or larger, rated at least
300V, as required by local codes) available at all electrical supply/hardware stores.

Early warning fire detection is best achieved by the installation of fire detection equipment in
all rooms and areas of the household as follows: A smoke alarm installed in each separate
sleeping area (in the vicinity of, but outside of, the bedrooms) and heat or smoke alarms in
living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets, utility storage
rooms, basements and attached garages. Test the smoke alarm weekly to assure proper
operation.

3.

Attach the mounting ring to the electrical junction box.

4.

To activate 9 volt battery and smoke alarm, pull and remove the thin colored plastic tab at
battery door hinge. Discard plastic tab.

5.

Plug the AC QUICK CONNECTORS together. Push and turn the smoke alarm clockwise onto
the mounting ring.

6.

See "TAMPER LOCKING PIN."

7.

Turn on AC power and check the LED's for proper operation. The green LED lights to indicate
AC power. The red LED will flash every 40-60 seconds to indicate proper operation.

Содержание SS-795

Страница 1: ...OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYINGWITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES but SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKE ALARMS CANNOTWORKWITHOUT...

Страница 2: ...preferred to avoid the thermal barrier that may form at the ceiling When mounting smoke alarm on the ceiling locate it a minimum of 4 10cm from a side wall or corner see Diagram A When mounting smoke alarm on a wall if local codes allow use an inside wall with the top edge of the smoke alarm a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling wall intersections See Diagram A Mobile Ho...

Страница 3: ...rical codes in your area Article 760 of the National Electrical Code NFPA 72 101 SBC SBCCI UBC ICBO NBC BOCA OTFDC CABO and any other local or building codes that may apply Wiring and installation must be performed by a licensed electrician Failure to follow these guidelines may result in injury or property damage This unit must be powered by a 24 hour 120V AC 60Hz circuit Be sure the circuit cann...

Страница 4: ...be powered from a single AC branch circuit If local codes do not permit be sure the neutral wire is common to both phases The maximum wire run distance between the first and last smoke alarm in an interconnected system is 1 000 feet NOTE Use standard household wire 18 gauge or larger rated at least 300V as required by local codes available at all electrical supply hardware stores Early warning fir...

Страница 5: ...ushing the test button on the smoke alarm cover for at least three seconds The smoke alarm will automatically reduce sensitivity and beep every 30 40 seconds for approximately 8 minutes to indicate the alarm is in the temporary silent condition The smoke alarm will gradually reactivate during the 8 minutes and sound the alarm if particles of combustion are still present The silence feature may be ...

Страница 6: ...ure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 2 2 1 1 1 Smoke detectors shall be installed outside of each separate sleepin...

Страница 7: ...ct to Universal Security Instruments Inc at 7 A Gwynns Mill Court Owings Mills Maryland 21117 postage prepaid with a payment of 4 00 to cover the costs of return postage and handling You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN...

Отзывы: