Universal IoPhic MDS300 Скачать руководство пользователя страница 5

Page 5

MOUNTING INSTRUCTIONS

1.  Attach the mounting bracket in the proper location on the wall or ceiling (screws and anchors 

provided).

2.  To activate 9 volt battery and alarm, hold the battery, pull and remove the PULL-TAB.  Confirm 

that the entire PULL-TAB has been completely removed. Discard PULL-TAB.

3.  Push and twist the alarm clockwise onto the mounting bracket.

4.  See  "OPTIONAL TAMPER  RESISTANT  FEATURE"  and  "TO ACTIVATE THE  LOCKING 

FEATURE" instructions on Page 4.

5.  The red LED will blink on approx. every 40-45 seconds to indicate proper operation.

OPERATION, TESTING & MAINTENANCE

OPERATION:

 The smoke alarm is operating once the battery power is connected by removing 

the PULL-TAB. When products of combustion are sensed, the alarm sounds a loud alarm which 

continues until the air is cleared.

This alarm incorporates the NFPA recognized horn signal for evacuation. During alarm mode, the 

horn produces three beeps followed by a two second pause and then continually repeats.

READY/ACTIVE CONDITION:

 The red LED blinks on once approx. every 40-45 seconds to indicate 

the alarm is properly functioning.

ALARM CONDITION:

 The red LED blinks on once approx. every 2 seconds and the alarm emits 

a loud, pulsating alarm sound.

NUISANCE ALARMS:

 

The smoke alarm is designed to minimize nuisance alarms. Smoking will 

not normally set off the alarm unless smoke is blown directly into the smoke alarm. Combustion 

particles from cooking may set off the alarm if the smoke alarm is located close  to the kitchen 

cooking surface. Large quantities of combustion particles are generated from spills or broiling.

If the smoke alarm does sound, check for fires first. If a fire is discovered, get out and call the fire 

department. If no fire is present, check to see if one of the reasons listed above may have caused 

the alarm. Use the Silence Feature if it is a nuisance alarm, or reset the alarm by pressing and 

holding the test button for ten seconds. Refer to RESET below.

NOTE: It is best to "reset" the alarms before initial test is performed. See below for Reset procedures.

TESTING:

 Test by pressing the Test button on the smoke alarm cover until the alarm sounds, 

then release. The alarm sounds if all electronic circuitry, horn and battery are working. If no alarm 

sounds, the alarm may have a power supply failure. 

Test the smoke alarm weekly to assure 

proper operation. IMPORTANT: 

Under normal conditions, the test button should sound the alarm 

immediately after it is pressed. There are special conditions that, when you press the Test button, 

you will experience a delay of approx. 10-15 seconds before the alarm sounds. This delay occurs 

if the test button is pressed during a self-diagnostic period. This occurs: (1) Upon initial power up; 

(2) After battery replacement. Retest after 10-15 seconds.

RV INSTALLATION

WARNING:

 TEST SMOKE ALARM OPERATION AFTER VEHICLE HAS BEEN IN STORAGE, 

BEFORE EACH TRIP AND AT LEAST ONCE PER WEEK DURING USE. An identical marking is 

to be provided by the recreational vehicle manufacturer that shall be permanent and located visibly, 

within 24 inches (810mm) of the smoke alarm.

ALARM ORIGINATION: 

The QUICK FIND

®

  feature  will  allow  you  to  immediately  locate  the 

originating  alarm  (once  the  alarm  has  stopped  sounding). To  initiate  QUICK  FIND

®

, press the 

Test/Silence button on each alarm. After releasing the button, the originating alarm will continue to 

sound for 60 seconds. It is necessary to test each alarm to determine the originating alarm in a 9 

volt non-interconnected installation.

RESET:

 

To reset the QUICK FIND

®

 Alarm Origination condition, press and hold the Test 

button on any alarm for at least 10 seconds and then release, or temporarily remove (and 

then replace) the battery. This will clear alarm origination indicator. Reset after each alarm 

activation.

END-OF-SERVICE LIFE NOTIFICATION:

 A majority of home fire deaths are a result of no smoke 

alarms or no 

working

 smoke alarms. In addition to the "replace by date" stamped on the back of 

your alarm, your alarm contains a unique audible end-of-service life notification feature. When it is 

time to replace your alarm, which is after approximately 10 years of operation from initial power up, 

the alarm will sound 1 beep approx. every 60 seconds and the red LED will blink on once approx. 

Содержание IoPhic MDS300

Страница 1: ...Instructions 5 Operation Testing Maintenance 5 RV Installation 5 QUICK FIND Alarm Originating Feature Reset 5 Silence Feature 6 Cautions Warnings 6 Battery Replacement 6 Develop and Practice a Plan of Escape 7 Operational Summary 8 Warranty Back Cover READ ALL INSTRUCTIONS This smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber Do not tamper with radioact...

Страница 2: ... PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES BUT SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE Homeowners and renters alike should continue to insure their lives and properties SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not ...

Страница 3: ...tically to the peak Sloped Ceilings Shed Ceilings Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Smoke Alarms or smoke detectors shall be installed on the highest portio...

Страница 4: ...TION THIS SMOKE ALARM IS SEALED THE COVER IS NOT REMOVABLE A mounting bracket is provided on the back of the alarm Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting the alarm in the direction indicated by the TWIST TO REMOVE arrow on the side of the alarm base OPTIONAL TAMPER RESISTANT FEATURES There are two separate tamper resistant locking featur...

Страница 5: ...ee below for Reset procedures TESTING Test by pressing the Test button on the smoke alarm cover until the alarm sounds then release The alarm sounds if all electronic circuitry horn and battery are working If no alarm sounds the alarm may have a power supply failure Test the smoke alarm weekly to assure proper operation IMPORTANT Under normal conditions the test button should sound the alarm immed...

Страница 6: ...0 years under normal operating conditions Replace the battery with only LITHIUM type ULTRALIFE U9VL J OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN To make your battery drawer tamper resistant a locking pin has been provided breakaway part on mounting bracket NOTE If this feature has been activated you will need to deactivate it by removing the battery drawer tamper pin located at side of battery dra...

Страница 7: ...against it open it slightly and be ready to slam it shut if heat and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to...

Страница 8: ...nstallation Blinks On once approx every 40 45 seconds Condition Alarm needs to be reset due to varying conditions previous alarms Recommendation To Reset theAlarm hold the Test Silence button for approx 10 seconds and release or temporarily remove and then replace the battery This will clear alarm origination Reset alarm after every alarm activation Silent 1 Chirp approx every 40 seconds Condition...

Страница 9: ...ALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS SUCH LAW OTHERWISE PROVIDES USI SPECIFICALLY DISCLAIMS ANY LIABILITY AND SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE INCLUDING BUT ...