INSTALLING THE COMBINATION SMOKE/CO ALARM

FOR RESIDENTIAL USE

LOCATION

Before installing your combination smoke/CO alarm, it is important to choose the best
locations in your home. Placement can affect how well the alarm performs and how well
residents hear the alarm if it sounds. Statistics of the National Fire Protection Association
(NFPA) show that most of the fatal CO occurrences happen at night while people are
sleeping.

Early warning of CO is best achieved by the installation of CO alarms on all floors and
areas of the household.

RECOMMENDATIONS

– Put a CO alarm inside each bedroom where the occupant closes the door while sleeping.

Particulate smoke can be blocked by a closed door, but CO fumes are likely to get
through.

– A CO alarm should be installed between 5 and 20 feet from potential sources of CO in

any family living unit containing a fuel-burning appliance or fireplace or having an attached
garage.

– A combination smoke/CO alarm should be centrally located outside of each separate

sleeping area in the immediate vicinity of the bedrooms. Where bedrooms are separated
and audibility of the alarm to occupants within the bedroom area could be seriously
impaired, more than one unit could be needed.

– If a bedroom area hallway is more than 30 feet long, install a smoke alarm at each end.
– Alarms can alert you to a problem only after smoke or CO reach their sensors. Choose

locations free of obstructions, where the alarm will stay clean and protected from adverse
environmental conditions.

– Install a smoke or combination alarm on the basement ceiling at the bottom of the stairwell.
– Make sure the alarms can be easily heard from multiple locations throughout the home.
– This combination smoke/CO alarm makes it easy to provide both types of protection

throughout the home.

– This combination smoke/CO alarm is designed to be used in single-family homes. It

alone may not meet requirements for multiple-resident dwellings (apartment buildings,
boarding houses, hotels or motels).

FIGURE 2

Содержание CD-9775

Страница 1: ...ITCHEN OR IN A HIGH HUMIDITY AREA NEAR A SHOWER CAN CAUSE FALSE ALARMS DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED Properly locate your alarm to avoid nuisance alarms A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAM...

Страница 2: ...children and household pets may be the first affected Your combination smoke CO alarm is designed to detect the toxic CO fumes that result from incomplete combustion such as those emitted from appliances furnaces fireplaces and auto exhaust This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor Carbon monoxide gas may be present in other areas This product is inte...

Страница 3: ...at and smoke rush in o Stay close to the floor if air is smoky Breathe shallowly through a cloth wet if possible o Once outside go to your selected meeting place and make sure everyone is there o Call the fire department from your neighbor s home not from yours o Don t return to your home until fire officials say that it is all right to do so Page 3 IMPORTANT CONSIDERATIONS YOURCOMBINATIONSMOKE CO...

Страница 4: ... having an attached garage A combination smoke CO alarm should be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms Where bedrooms are separated and audibility of the alarm to occupants within the bedroom area could be seriously impaired more than one unit could be needed If a bedroom area hallway is more than 30 feet long install a smoke alarm at e...

Страница 5: ...n the ceiling This is especially important if the ceiling is unusually hot or cold Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area AVOID THESE LOCATIONS the garage products of combustion are present when you start your automobile in areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 3 feet 0 9 mete...

Страница 6: ...to the mounting bracket check to make sure a battery is installed 1 To activate 9 volt battery and alarm hold the QUICK DRAWTM pull out battery drawer closed pull and remove the PULL TAB Discard PULL TAB NOTE After initial battery power up the Green LED will flash on rapidly approximately 20 times and then remain off Proceed to test the alarm 2 See TAMPER LOCKING PIN 3 Press the TEST SILENCE butto...

Страница 7: ... of alarm Be sure all the vents are free of debris END OF SERVICE LIFE NOTIFICATION A majority of home fire deaths are a result of no smoke alarms or no working smoke alarms In addition to the replace by date stamped on the back of your alarm your alarm contains a unique audible end of service life notification feature When it is time to replace your alarm which is approximately 7 years of operati...

Страница 8: ...harge for repairing out of warranty units NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be in...

Страница 9: ... Cronhill Drive Suite A Owings Mills Maryland 21117 You must include a proof of purchase receipt along with the returned product UNIVERSAL DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRAN...

Отзывы: