background image

8

Operating Instructions and Owner’s Manual

 GAS-FIRED INFRA-RED PORTABLE CONSTRUCTION HEATER

MODELS 125-RN / 125-R

4

3

2

1

5

6

7

8

9

10

11

12

13

Combustion Chamber

Mounting Bracket

Pilot Supply Tube

Pressure Test Port

Propane Hose

Top Plate

Frame Assembly

Содержание 125-R

Страница 1: ...ONSPROVIDEDWITHTHISHEATER CANRESULTINDEATH SERIOUSBODILYINJURYANDPROPERTYLOSSORDAMAGEFROM HAZARDSOFFIRE EXPLOSION BURN ASPHYXIATION CARBONMONOXIDEPOISONING AND OR ELECTRICALSHOCK ONLYPERSONSWHOCANUNDERSTANDANDFOLLOWTHEINSTRUCTIONSSHOULDUSEOR SERVICETHISHEATER IFYOUNEEDASSISTANCEORHEATERINFORMATIONSUCHASINSTRUCTIONMANUALS LABELS ETC CONTACTTHEMANUFACTURER WARNING FIRE BURN INHALATIONANDEXPLOSIONHAZ...

Страница 2: ...e this heater in a space where gasoline or other liquids having flammable vapors are stored or used WARNING DONOTEXCEED psi 14 w c GAS PRESSURETOTHEGASCONTROLVALVE SPECIFICATIONS MODEL NO 125 R 125RN GAS TYPE LP Gas Natual Gas MAX INLET PRESSURE 14 IN W C 14 IN W C MIN INLET PRESSURE 13 5 IN W C 7 IN W C MANIFOLD PRESSURE 12 5 IN W C 6 IN W C VENTILATION WARNING THISAPPLIANCEISUNVENTEDANDMUSTBE US...

Страница 3: ...ping water Use of this heater in a draft windy area decreases its efficiency If possible operate the unit in a draft free area PIPING For Model 125 R for use with LP Gas This model may be connected to a self contained LP Gas supply system using the hose and regulator assembly supplied with the appliance OR it may be connected to a permanentlyinstalledLP Gassupplysystem If connected to a self conta...

Страница 4: ...t your sensitivity to that particular odor Odors present in animal confinement buildings can mask fuel gas odor The odorant in propane LP gas and natural gas is colorless and the intensity of its odor can fade under some circumstances If there is an underground leak the movement of gas through the soil can filter the odorant Propane LP gas odor may differ in intensity at different levels Since Pro...

Страница 5: ...ntial for physical damage to the appliance is reduced to a minimum The owner operator of this appliance must ensure that precautions are taken to protect the appliance from physical damage LIGHTINGANDSHUTDOWN Lighting the Heater 1 Before attempting the light the heater smell all around the heater area for gas Be sure to smell next to the floor because LP Gas is heavier than air and will settle on ...

Страница 6: ... provide properly sized flame Rotate the key clockwise to decrease or counter clockwise to increase flame 3 Replace the pilot adjustment cap MAINTENANCEINSTRUCTIONS This heater including hose and regulator assembly if applicable must be inspected before each use If the hose for the Model 125 R shows evidence of excessive abrasion or wear or if the hose is cut it must be replaced prior to the heate...

Страница 7: ...TION REF ITEM DESCRIPTION 1 00332 Manual Control Valve 2 04466 Filter Diffuser 3 05363 Orifice Pilot 125 R 4 09352 Thermocouple 5 11357 Pilot Burner 6 11695 Regulator 125 R 7 11666 Regulator 125 RN 8 05374 Orifice Pilot 125 RN 9 CR805 Ignitor 10 CR835 Piezo 11 CR820 Axle 12 CR815 Axle Brackets 13 CR810 Wheel Figure 2 Figure 1 ...

Страница 8: ...ions and Owner s Manual GAS FIREDINFRA REDPORTABLECONSTRUCTIONHEATER MODELS 125 RN 125 R 4 3 2 1 5 6 7 8 9 10 11 12 13 Combustion Chamber Mounting Bracket PilotSupplyTube PressureTestPort PropaneHose TopPlate FrameAssembly ...

Страница 9: ...manufactured and sold will be free from defects in material and workmanship Parts assemblies controls etc furnished by Scheu Products Co will carry a one 1 year warranty on the applicable warranties of the suppliers The sole responsibility of Scheu Products Co under this warranty shall be to replace or repair any part for which a written claim is made to Scheu Products Co within the time limit of ...

Отзывы: