Universal Tool UT8745 Скачать руководство пользователя страница 5

Operation

Operating the angle grinder

 

This Angle Grinder is designed to operate on 90 PSIG. 
Lower pressure (below 90 PSIG) will reduce performance 
of the tool. Higher air pressure (over 90 PSIG) raises the 
performance of the tool beyond its rated capacity and 
could cause serious damage to the tool and the user. 
 
  
 
 
 

Installing the grinding wheel 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

WARNING:

  Always use ANSI approved grinding stones 

with the rated tool RPM.

Removing the grinding wheel 

 

 

WARNING:

 Disconnect the tool from the air supply before 

servicing or changing accessories.

Grinding and deburring 

 

WARNING:

 You must wear the ANSI approved eye 

protection during the operation; failure to follow this this may 
result in serious injury or damage to the operator.

WARNING:

 Hearing protection is strongly recommended. A 

protective respirator is recommended.

 

 

Remove the flange nut with the disc 
and spanner wrench. 

 

Mount the grinding wheel on the 
spindle. 

 

Replace the flange nut and re-
tighten using the disc and spanner 
wrench.

 

Connect the grinder to the air supply.  

 

This tool features the safety lock-off mechanism.

 

Operate the tool by disengaging the lock-off mechanism 
and depressing the throttle lever to run the tool for grinding.

 

Remove flange nut with the disc and spanner wrench. 

 

Remove the grinding wheel, and replace the flange nut 
using the disc and spanner wrench.

Содержание UT8745

Страница 1: ...instructions and warnings before operating any pneumatic tool TABLE OF CONTENTS General Safety Information 2 Air Compressor and Air Tool Safety 2 3 Tool Specifications 3 Installation 4 Maintenance Lubrication 4 Operation 5 Troubleshooting 6 Warranty 6 Service Parts 7 WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive har...

Страница 2: ...s essential If the pneumatic tool is used in a dust filled environment exhaust air can cause a dust hazard Dusts and fumes generated when using power tools can cause ill health for example cancer birth defects asthma and or der matitis risk assessment of these hazards and implementation of appropriate controls of is essential Risk assessment should include dust created by the use of the tool and t...

Страница 3: ...uing the operation 4 Grinding wheels and cut off wheels shall not be used for side grinding Exception grinding wheels designed for side grinding Grinders should not be used over the maximum rated speed of an abrasive product 5 The operator shall pay attention that no bystanders are in the vicinity 6 The personal protective equipment such as gloves apron and helmet shall be used 7 Never operate the...

Страница 4: ...he tool from operating if the throttle is accidentally engaged LUBRICATION An in line filter regulator lubricator is recommended as it increases tool life and keeps the tool in sustained operation Regularly check and fill the in line lubricator with air tool oil Avoid using excessive amounts of oil Adjust the in line lubricator by placing a sheet of paper next to the tool s exhaust ports and holdi...

Страница 5: ...hanging accessories 4 Grinding and deburring WARNING You must wear the ANSI approved eye protection during the operation failure to follow this this may result in serious injury or damage to the operator WARNING Hearing protection is strongly recommended A protective respirator is recommended Remove the flange nut with the disc and spanner wrench Mount the grinding wheel on the spindle Replace the...

Страница 6: ...and grease the bearing with bearing grease There is moisture blowing out of the tool s exhaust There is water in the tank Drain the tank See the air compressor manual for instructions Lubricate the tool and run it until water is not evident Lubricate the tool again and run for 1 2 seconds Warranty Limited Warranty Universal Tool warrants its tools to be free from defects in material and workmanshi...

Страница 7: ... Tool a Division of Florida Pneumatic Mfg Corp 851 Jupiter Park Lane Jupiter FL 33458 Universal Air Tools Company Ltd Unit 8 Lane End Industrial Park High Wycombe HP14 3BY UK Service Parts Exploded View Drawing ...

Страница 8: ... 9ST30409A HOUSING 1 9ST3041136 2 SHAFT M14 2 1 10 912012 1 PIN 1 37 9ST70407 1 KEY 1 11 9ST120A13 LEVER 1 38 9ST80537 3 FACE PLATE 1 12 9OB 04 O RING 1 39 9ST70403A SCREW 4 13 9OB 101 05 1 VALVE STEM 1 40 9ST85562A DISC NUT 5 8 11 1 14 9OB 30 SNAP RING 1 40A 9ST85562 1A DISC NUT M14 2 1 15 9ST30415 1 CLAMP NUT 1 985563A DISC NUT 5 8 11 1 1 17 980441 SHROUD 1 9ST85563 1A DISC NUT M14 2 1 18 921024...

Страница 9: ...94 883300 Universal Air Tools Company Ltd Unit 8 Lane End Industrial Park High Wycombe HP14 3BY UK sales universal co uk www universal co uk Call Customer Service 8 a m 5 p m EST Monday Friday 1 800 356 3392 Universal Tool a Division of Florida Pneumatic Mfg Corp 851 Jupiter Park Lane Jupiter FL 33458 www Florida Pneumatic com US UK ...

Отзывы: