background image

Operating

Select a suitable abrasive disc (see Section "Foreseen use of the tool")
and make sure that it is fixed securely to the tool. Connect to suitable air
supply as recommended. Make sure that the side handle is tightened
securely.
Apply the sander lightly to the work and allow the abrasive disc to cut.
Take great care when sanding around sharp edges and surfaces to
avoid the disc snagging i.e. the disc may be brought to an abrupt stop or
considerably slowed that will cause the tool to kick in the hands.
It is always recommended to use safety glasses and a breathing mask.
The sanding of certain materials may create a hazardous dust which
may require special breathing equipment. Check before using the tool.
Even if the machine has a low noise level the actual sanding process
may cause a noise level such that ear protectors will be required. If there
are  sharp  areas  on  the  material  being  sanded  safety  gloves  are
recommended.
Do not continue to use abrasive discs that are worn or clogged. This will
make  the  sanding  process  inefficient  and  the  need  to  apply
unnecessarily high forces to the tool.
Do not use undersized or oversized sanding discs. The disc should be
no more than 1/4" larger in diameter that the pad, and not smaller than
the pad.

Safety Rules For A Sander

1) Read all the instructions before using this tool. All operators must be
fully trained in its use and aware of these safety rules.
2) Do not exceed the maximum working air pressure.
3) Use personal safety equipment.
4) Use only compressed air at the recommended conditions.
5) If the tool appears to malfunction remove from use immediately and
arrange for service and repair.
6) If the tool is used with a balancer or other support device ensure that
it is fixed securely.
7) Always keep hands away from the working attachment fitted to the
tool.
8) The tool is not electrically insulated. Never use the tool if there is any
chance of it coming into contact with live electricity.
9) Always when using the tool adopt a firm footing and/or position and
grip the tool firmly to be able to counteract any forces or reaction forces
that may be generated whilst using the tool.
10) Use only correct spare parts. Do not improvise or make temporary
repairs.
11) Do not lock, tape, wire, etc. the on/off valve in the run position. The
trigger/lever etc. must always be free to return to the 'off' position when
it is released.
12)  Always  shut  off  the  air  supply  to  the  tool,  and  depress  the
trigger/lever etc. to exhaust air from the feed hose before fitting,
adjusting or removing the working attachment.
13) Check hose and fittings regularly for wear. Replace if necessary. Do
not carry the tool by its hose and ensure the hand is remote from the
on/off control when carrying the tool with the air supply connected.
14) Take care against entanglement of moving parts of the tool with

clothing, ties, hair, cleaning rags, etc. This will cause the body to be
drawn towards the tool and can be very dangerous.
15) It is expected that users will adopt safe working practices and
observe  all  relevant  legal  requirements  when  installing,  using  or
maintaining the tool.
16) Do not install the tool unless an easily accessible and easily operable
on/off valve is incorporated in the air supply.
17) Take care that the tool exhaust air does not cause a problem or
blows on another person.
18) Never lay a tool down unless the working attachment has stopped
moving.
19) Always check the speed of the attachment is higher than the speed
of the tool.
20) Check speed of tool at regular intervals.
21) Check always that the material to be sanded may not cause a risk by
being sanded, i.e. fire or explosion.
22) If self fixing discs are used, i.e. self adhesive or Velcro, always ensure
the disc is fixed centrally to the pad.

It is recommended that the air pressure at the tool whilst the tool is
running is 90 p.s.i./6.3 bar. The tool can run at lower and higher
pressures with the maximum permitted working air pressure of 100
p.s.i./7 bar.

Page No 2

Tool Maintenance

It shall be the tool owner’s and/or employer’s responsibility to assure
that  tools  are  maintained  in  a  safe  operating  condition.  Tool
maintenance and repair shall be performed by authorised, trained,
competent  personnel.  Tools  shall  be  disconnected  from  their
compressed air supply before repairs are attempted. Repairs shall be
consistent with the manufacturer’s recommended procedures. Tool,
hoses and fittings shall be replaced if unsuitable for safe operation. It
shall be the tool owner’s and/or employer’s responsibility to keep
required rating markings and warnings on the tool in legible condition.

Содержание UT8708

Страница 1: ...the tool of 90 p s i 6 3 bar when the tool is running with the trigger fully depressed Use recommended hose size and length It is recommended that the tool is connected to the air supply as shown in figure 1 Do not connect the tool to the air line system without incorporating an easy to reach and operate air shut off valve The air supplyshouldbelubricated Itisstronglyrecommendedthatanairfilter reg...

Страница 2: ...ise or make temporary repairs 11 Do not lock tape wire etc the on off valve in the run position The trigger leveretc mustalwaysbefreetoreturntothe off positionwhen it is released 12 Always shut off the air supply to the tool and depress the trigger lever etc to exhaust air from the feed hose before fitting adjusting or removing the working attachment 13 Check hose and fittings regularly for wear R...

Страница 3: ... UT OB 35 2 Housing Cover 38 UT OB 36 Screw 4 41 UT OB 39 Stop Spanner 44 ST S560 41 3SET Vacuum Adapter Swivel 45 OB 42 Shroud 49 UT OB 23 Pin Ref No Part No Description 1 UT OB 01 Regulator 2 UT OB 02 O Ring 2 3 UT OB 03 Snap Ring 4 UT OB 04 O Ring 5 UT OB 05 Valve Stem 6 UT OB 06 Washer 7 UT OB 16 1 Washer 8 UT OB 08 Valve 9 UT OB 09 Spring 10 UT 70426 Air Inlet 11 UT OB 11 Muffler Body 12 UT O...

Страница 4: ... Air Tool Company Limited Unit 8 Lane End Industrial Park High Wycombe Bucks HP14 3BY England declare under our sole responsibility that the product Model UT8708 Dual Action Palm Sander Serial Number to which this declaration relates is in conformity with the following standard s or other normative document s EN792 Draft EN292 Parts 1 2 ISO 8662 Parts 1 2 14 Pneurop PN8NTC1 following the provision...