Mobile Home Installation:

For minimum protection, smoke alarms  should be installed in compliance with H.U.D.  
Manufactured Home Construction Safety Standards, Title 24 CFR, Section 3280.208 and 
Section 3282. For additional protection, see Single Story Residence smoke alarm  
requirements/recommendations for Existing Homes and New Construction Homes.

Note: For mobile homes built before 1978, install smoke alarms or combination alarms on  
inside walls between 4” and 12” from the ceiling (older mobile homes have little or no insula-
tion in the ceiling). This is especially important if the ceiling is unusually hot or cold.

Install smoke alarms or combination alarms inside each bedroom and in the hallway outside 
each separate sleeping area.

WHERE THIS ALARM SHOULD NOT BE INSTALLED

Installation in an improper location can affect the sensitive electronic components in this alarm. 
This alarm is not suitable for installation in hazardous locations as defined in the National  
Electrical Code. 

To avoid causing damage to this alarm, to provide maximum protection, and to prevent 
unnecessary alarms, DO NOT LOCATE THIS ALARM:

•  In extremely humid areas. This alarm should be at least 3 feet (0.9m) from a bath or 

shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room or other source 
of high humidity.

•  In very cold or very hot environments or in unheated buildings or outdoor rooms where the 

temperature can go below or above the operating range of the alarm.

•  In garages, kitchens crawl spaces and unfinished attics. 
•  In turbulent air, such as near ceiling fans, heat vents, air conditioners, fresh air returns or 

open windows. Blowing air may prevent smoke or CO gas from reaching the sensors. 

•  In extremely dusty, dirty or greasy areas. Installation in these areas could lead to nuisance 

alarms, may expose the sensor to substances which could damage or contaminate the 
alarm.

•  In the garage, vehicle exhaust can contain some carbon monoxide. These levels are higher 

when the engine is first started. Within hours of starting a vehicle and backing it out of the 
garage, the levels present over time can activate the alarm and become a nuisance. 

Содержание Sensing Plus AMIC3511S

Страница 1: ...uct Features 2 Alarm Limitations and Functions 2 Installation Instructions 3 Where This Alarm Should Be Installed 3 Where This Alarm Should Not Be Installed 5 Mounting Instructions 6 Tamper Resistant...

Страница 2: ...UNCTIONS IMPORTANT ALARMS WILL NOT WORK WITHOUT POWER Therefore installing an alarm with a sealed battery or an alarm powered from two different power sources can give an extra measure of protection A...

Страница 3: ...ays be replaced after 10 years DO NOT PAINT THE ALARM Paint may clog the openings to the sensing chambers and prevent the alarm from operating properly DO NOT STAND TOO CLOSE TO THE ALARM WHEN IT IS S...

Страница 4: ...wall with the top edge of the smoke alarm up to a maximum of 12 30 5cm below the ceiling wall intersec tions See Diagram A Existing Homes The NFPA requires smoke alarms or combination alarms on every...

Страница 5: ...ional Electrical Code To avoid causing damage to this alarm to provide maximum protection and to prevent unnecessary alarms DO NOT LOCATE THIS ALARM In extremely humid areas This alarm should be at le...

Страница 6: ...anted nuisance alarms Nuisance alarms may occur if an alarm is placed directly next to a fuel burning source Ventilate these areas as much as possible MOUNTING INSTRUCTIONS To use the optional Alarm T...

Страница 7: ...asements and excluding crawl spaces and unfinished attics 5 In the living area s of a guest suite 6 In the living area s of a residential board and care occupancy small facility The equipment should b...

Страница 8: ...e the Silence feature until the source of the alarm has been identified and safe conditions exist The Silence feature is intended to temporarily silence the horn while identifying and correcting the p...

Страница 9: ...ill a problem call customer service Do not attempt to fix the alarm ALARM AND BATTERY DEACTIVATION This alarm uses a sealed battery for power The battery should last for approximately 10 years under n...

Страница 10: ...rm to stop a nuisance alarm Doing so will disable the alarm and remove the protection In the case of a true unwanted alarm use the silence feature The silence feature is intended to temporarily silenc...

Страница 11: ...Vent pipe connections improperly designed or becoming loose Improper use of appliances by operating a barbeque grill using charcoal gas or wood pellets hibachi in an enclosed area such as a garage or...

Страница 12: ...our home when they hear the sound Identify children s bedrooms with red stickers placed in the upper left corner of the windows They are available from your local fire department Practice a fire drill...

Страница 13: ...t Silence button for 10 15 seconds This will clear alarm origina tion Reset after each alarm event Previous alarm condition at unidentified source Silent alarmed previously Blinks on approx every 2 mi...

Страница 14: ...imately 5 20 seconds If it is not the originating alarm continue to each alarm until the originating alarm is located 2 Once this test sequence ends the originating alarm continues to sound for approx...

Страница 15: ...n or limitation of incidental or consequential damages so the above limitations or exclusions may not apply to you No agent representative dealer or employee of the company has the authority to increa...

Отзывы: