Page 13
C O N D I T I O N
New-Out of package .
The Test button has been
pressed . The test sequence
lasts for approx 10 seconds .
ALARM AUDIBLE & VISUAL SIGNALS
HORN
Silent
3 Beeps, 6
second pause,
4 beeps.
SMK RED
LED
Off
Blinks On in
sync with 3
beeps .
CO RED
LED
Off
Blinks On
in sync with
4 beeps.
RECOMMENDATION
To activate the alarm remove the pull tab .
The alarm will sound one long beep to confirm
it is powered up .
DC power is present .
Silent
Blinks On
approx . every
2 minutes .
Off
Alarm is operating properly .
RESET INSTRUCTIONS: Press the Test/Silence button for 10-15 seconds and then release . This will clear the alarm origination . Be
sure to RESET alarms after each alarm event .
QUICK FIND® Alarm Origination/Location Feature: The QUICK FIND® feature will allow you to immediately locate the originating
alarm (the alarm that triggered the other alarms), once the alarms have stopped sounding.
1 . Press and release the Test/Silence button on alarm . After releasing the button, the test sequence on this alarm will begin, and
last approximately 5-20 seconds . If it is not the originating alarm, continue to each alarm until the originating alarm is located .
2 . Once this test sequence ends, the originating alarm continues to sound for approximately 60 seconds, which provides ample
time to locate the originating alarm .
3 . Remember to reset the originating alarm in order to clear the QUICK FIND® and return the system to normal operation .
NOTE: If you have any additional questions about the operation, please contact our Customer Service Department at 800-390-4321,
and we will gladly assist you .
THIS PRODUCT IS LISTED TO UL STANDARD FOR SAFETY, UL 217 and UL 2034
Test the alarm following installation and weekly
thereafter . The built-in test switch accurately
tests the alarm operation as required by ANSI/
UL217 and UL2034 Standards for Safety. If,
at any time, the alarm does not perform as de-
scribed during the test, replace it immediately .
Originating Smoke Alarm .
3 Beeps,
2 second
pause, repeat
Blinks On in
sync with the
3 beeps
Off
If hazard is identified, please take all precau-
tions if an alarm sounds by calling Emergency
Service and getting out of the home .
Originating CO alarm
4 Beeps, 5
second pause,
repeat
Blinks on
approx . every
2 minutes
Blinks On in
sync with the
4 beeps
If hazard is identified, please take all precau-
tions if an alarm sounds by calling Emergency
Service and getting out of the home .
Nuisance alarm
Horn sounds
when no hazard
present
Blinks On in
sync with the
3 beeps
Blinks On in
sync with the
4 beeps
If there is no hazard present, verify the alarm
is mounted in the correct location (see user’s
manual). Reset alarm as instructed below.
Smoke alarm when cause
of alarm is known and poses
no threat
3 Beeps,
2 second
pause, repeat
Blinks On in
sync with the
3 beeps
Off
The smoke alarm Silence Feature can be
activated by pressing and releasing the Silence
button while in alarm condition . Silence mode
will last for approximately 8 - 12 minutes [With
the red smoke LED blinking on approx every
10 seconds] .
Previous alarm condition at
unidentified source
Silent (alarmed
previously)
Blinks on
approx . every
2 minutes
Off
Quick Find® Alarm Origination - It may be dif-
ficult to determine which alarm has previously
sounded . The Quick Find® feature will allow
you to immediately locate the originating alarm
(once the alarm has stopped sounding). To
initiate Quick Find® press the Test/Silence
button on the alarm . After releasing the button
and following the test sequence, the originating
alarm will continue to sound for approximately
60 seconds .
CO alarm when cause of alarm
is known and poses no threat
4 Beeps, 5
second pause,
repeat
Blinks on
approx . every
2 minutes
Blinks On in
sync with the
4 beeps
The CO alarm Silence Feature can be
activated by pressing and releasing the Silence
button while in alarm condition . The alarm will
remain silent for approx 5 minutes [with the red
CO LED blinking on approx every 10 seconds],
depending on the level of CO detected . If CO
levels drop below alarm levels, the alarm will
remain silent and return to normal operation .
If CO levels remain constant or increase, this
indicates a potentially dangerous situation and
the horn will sound again . Ventilate area .
Alarm needing reset due
to abnormal operation/
previous alarms
Silent (alarmed
previously)
Blinks on
approx . every
2 minutes
Off
To reset the alarm, hold the Test/Silence button
for 10-15 seconds . This will clear alarm origina-
tion . Reset after each alarm event .
Low Battery or Product End-of-
Service Life Warning
2 Chirps approx
every 60
seconds
Blinks on
approx . every
2 minutes
Off
Deactivate alarm (See User’s Manual “ALARM
DEACTIVATION” section). Replace alarm
immediately .
Sensor Trouble Signal
3 Chirps approx
every 60
seconds
Blinks on
approx . every
2 minutes
Off
Reset the alarm . If this does not clear the
problem, replace alarm .
Содержание MPC322S
Страница 14: ...Page 14...