DO NOT TAMPER WITH WIRES WHEN POWER IS ON!

For alarms that are used as single smoke alarms, do not connect the yellow wire to anything.
Insulate this wire (tape it) in place to make certain the yellow wire cannot contact any metal parts.

Interconnected alarms can provide earlier warning of fire than stand-alone alarms, especially
if a fire starts in a remote area of the dwelling. When alarms are interconnected, all alarms
will sound when one alarm first goes into alarm. This alarm may be interconnected with a
total of not more than 24 interconnected devices, i.e., as many as 11 other USI ELECTRIC or
UNIVERSAL model smoke alarms or combination smoke and carbon monoxide (CO) alarms;
6 other initiating smoke alarms which may be a combination of USI ELECTRIC or UNIVERSAL
CO Alarms and Heat Alarms; and six other non-initiating devices such as USI ELECTRIC
Relay Modules. Compatible models include: 2995, 5304, MI100, MI106, MDS211,  2985, 5303,
MI200, MI210, MDS101, MDS107, USI-1103, USI-1203, USI-1204, USI-1208 (Part #USI-1209),
USI-1213, USI-3204, USI-7385, USI-7390, USI-7485, USI-7490, USI-7795, USI-2430, USI-960,
SS-785, SS-790, SS-795, SS-2795, SS-2895, CD-9385, CD-9390, CD-9485, CD-9490, CD-9795,
HD-130, RM-100.

Interconnected CO alarms or CO alarm circuit of combination smoke and CO alarms will only
respond if a CO alarm / event initiates the alarm. All other alarms remain silent.

Interconnected smoke alarms, heat alarms and relay modules will only respond if a smoke
alarm / event or heat alarm / event initiates the alarm. All CO alarms remain silent.

Note that smoke alarms without battery backup will not respond during an AC power failure.

NOTE: Relay Modules/USI-960 will not respond if a CO alarm / event initiates the alarm.

TO DEACTIVATE THE LOCKING FEATURES:

 To remove the smoke alarm for cleaning or servicing

or to replace the battery, you must first remove the appropriate locking pin, if it has been installed.

1.

Turn off AC power to the circuit.

2.

Use long nose pliers to pull the locking pin out of the hole.

3.

It is now possible to remove the smoke alarm or replace the battery.

WIRING INSTRUCTIONS:

1.

a.

The appropriate power supply is 120 Volt single phase power supplied from a non-switchable
circuit NOT protected by a ground fault circuit interrupter.

b.

Turn off AC power to the circuit before wiring the smoke alarm.

c.

There are three pigtail wires (black, white and yellow) coming from the AC QUICK
CONNECTOR. The proper wire connection is as follows:

WIRES FROM QUICK CONNECTORCONNECT TO

BLACK

"HOT" side of AC line

WHITE

"NEUTRAL" side of AC line

YELLOW

Interconnect wires of other smoke alarms

Page 5

2.

Insert the pin into the hole for the feature you are activating. Refer to the diagram below for
correct placement.

INSERT ALARM

LOCKING PIN HERE

INSERT BATTERY

LOCKING PIN HERE

Содержание MI100

Страница 1: ...ntenance 6 QUICK FIND Alarm Originating Feature Reset 6 Cautions Warnings 7 Backup Battery Replacement 7 Develop and Practice a Plan of Escape 8 Operational Summary 9 Warranty Back Cover SECURITY INST...

Страница 2: ...s A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELE...

Страница 3: ...Home Installation For minimum protection smoke alarms should be installed in compliance with H U D Manufactured Home Construction Safety Standards Title 24 CFR Section 3280 208 and Section 3282 For a...

Страница 4: ...for this model Activating one or both of these features deters someone from removing the smoke alarm from the mounting bracket or removing the battery from the alarm The breakaway locking pins are cl...

Страница 5: ...nd if a CO alarm event initiates the alarm All other alarms remain silent Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiat...

Страница 6: ...ORIGINATION The QUICK FIND Alarm Origination Feature allows the user to identify the initiating alarm smoke alarms in an interconnected alarm system If an interconnected alarm system is initiated by...

Страница 7: ...lence mode the smoke alarm will be tested normally Upon the release of the Test button the Silence mode will be restarted Before using the alarm Silence Feature identify the source of smoke and be cer...

Страница 8: ...he TEST button on the smoke alarm cover until the alarm sounds then release REPAIRS AND SERVICES This smoke alarm contains less than 1 microcurie 37 kilobecquerel ofAmericium 241 a radioactive materia...

Страница 9: ...alarm have a licensed electrician check to see if the yellow wire is connected to the neutral wire 3 Beeps 2 second pause Repeat Blinks On approx every 2 seconds Stays On Originating SmokeAlarm If haz...

Страница 10: ...ns E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send battery ONLY along with a note describing nature of difficulty and...

Отзывы: