MAN.500.REVD.06302015

Instruction Manual

500 Series

Thermoelectric Gas Coolers

(Units sold prior to 07-01-2015)

        

 5200 Convair Drive Carson City, NV 89706 • Phone: 775-883-2500 • Fax: 775-883-6388 • www.universalanalyzers.com

Содержание 500 series

Страница 1: ...00 REVD 06302015 Instruction Manual 500 Series Thermoelectric Gas Coolers Units sold prior to 07 01 2015 5200 Convair Drive Carson City NV 89706 Phone 775 883 2500 Fax 775 883 6388 www universalanalyzers com ...

Страница 2: ...ymbols 5 Specifications 6 Description and Principle of Operation 8 Installation 11 Electrical Connections 12 Start Up 18 Shutdown 18 Maintenance 19 Troubleshooting 20 Spare Parts 22 Drawings 23 Model 520 23 Model 530 24 Model 540 25 Model 560 26 Model 565 27 Model 570 28 Model 574 29 ...

Страница 3: ... 574 31 Relay Board for Models 520 530 560 565 32 Relay Board for Models 540 570 574 33 Drawings Heat Exchangers 34 Metallic Heat Exchangers Temperature Sensing All Models 34 Metallic Heat Exchangers Non Temperature Sensing All Models 36 Glass Kynar Temperature Sensing All Models 38 Glass Kynar Non Temperature Sensing All Models 40 Limited Warranty 42 ...

Страница 4: ...refully inspect the product and included accessories immediately on arrival by removing them from the packing and checking for missing articles against the packing list Check the items for any damage which may have occurred during transit and immediately inform the shipping insurance company of any damage found Refer to the Specifications section page 6 for information regarding storage requiremen...

Страница 5: ...ON PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED PER CLAUSE 5 4 4 i IN STANDARD EN 61010 1 CAUTION RISK OF DANGER SYMBOL INDICATES INJURY MAY OCCUR IF MANUFACTURER S INSTRUCTIONS ARE NOT ADHERED TO PLEASE READ MANUAL CAREFULLY WHEN SYMBOL IS DISPLAYED CAUTION HOT SURFACE SYMBOL INDICATES EXPOSED SURFACE TEMPERATURE CAN CAUSE BURNS OR PERSONAL INJURY CARE SHOULD BE TAKEN WHEN CONTACT IS REQUIRED CAUTIO...

Страница 6: ...mum Cooling Power Model 520 63 BTUs per hour 60 kJ hr Model 530 63 BTUs per hour 60 kJ hr Model 540 126 BTUs per hour 120 kJ hr Model 560 126 BTUs per hour 120 kJ hr Model 570 126 BTUs per hour 120 kJ hr Model 574 126 BTUs per hour 120 kJ hr Outlet Sample Dew Point 41 F 5 C Gas Sample Inlet Fitting 3 8 tubing fitting Gas Sample Outlet Fitting 1 4 tubing fitting Bottom Water Drain Fitting 3 8 tubin...

Страница 7: ... 5 kg Model 560 21 lbs 9 5 kg Model 570 25 lbs 11 5 kg Model 574 25 lbs 11 5 kg Soluble Gas Removal Rates NO 0 loss NO2 10 loss SO2 2 loss CO 0 loss CO2 2 loss Storage Requirements Cool and dry location 20 F x 120 F 95 relative humidity non condensing AT REDUCED FLOW RATE ABOVE 77 F 25 C AMBIENT DIMENSIONS DO NOT INCLUDE FITTINGS OR MOUNTING HARDWARE Specifications ...

Страница 8: ... SELECTION CHART Conditions Model Ambient Water 520 530 540 560 570 574 574 77 F 25 C 12 2 5 l m 4 0 l m 2 5 l m 5 0 l m 4 0 l m 5 0 l m 2 5 l m 15 2 0 l m 4 0 l m 2 0 l m 4 0 l m 4 0 l m 4 0 l m 2 0 l m 30 1 0 l m 4 0 l m 1 0 l m 2 0 l m 4 0 l m 2 0 l m 1 0 l m 50 0 6 l m 4 0 l m 0 6 l m 1 0 l m 4 0 l m 1 0 l m 0 6 l m 90 F 32 C 12 2 0 l m 3 0 l m 2 0 l m 4 0 l m 3 0 l m 4 0 l m 2 0 l m 15 1 8 l ...

Страница 9: ... is a green LED which indicates when the operating temperature has fallen below the factory set temperature of 10 C An Over temperature relay is energized and closed to the cool position when the COOL lamp is on The relay board within the enclosure has dual terminal strip relay contacts for alarm shutdown purposes The external gas sample pump may be interlocked with this relay to power off when te...

Страница 10: ...m should be available and visible to the operator This may be accomplished through the use of pressure regulators with gauges flowmeters and or flow control needle valves Condensate removal from the heat exchanger s within the Sample Cooler can be accomplished through one of the following methods 1 A continuously running peristaltic tubing pump 2 Installing the heat exchanger as a bypass condenser...

Страница 11: ...o an appropriate condensate disposal location A sample pump is normally required to pull the gas sample through the cooler A Water Carry Over Filter WCOF sensor is recommended for each sample path The pump should be located between the cooler and the filter A clear glass bowl should be installed around the filter to allow checking of the condition of the filter while online Each cooler consumes ab...

Страница 12: ...Page 12 of 44 MAN 500 REVD 06302015 Electrical Connections Model 520 ...

Страница 13: ...Page 13 of 44 MAN 500 REVD 06302015 Electrical Connections Model 530 ...

Страница 14: ...Page 14 of 44 MAN 500 REVD 06302015 Electrical Connections Model 540 ...

Страница 15: ...Page 15 of 44 MAN 500 REVD 06302015 Electrical Connections Model 560 ...

Страница 16: ...Page 16 of 44 MAN 500 REVD 06302015 Electrical Connections Model 570 ...

Страница 17: ...Page 17 of 44 MAN 500 REVD 06302015 Electrical Connections Model 574 ...

Страница 18: ...lize between 4 and 5 C Start the sample gas flow Water should be observed to be removed from the bottom of the heat exchanger when steady state conditions are established If moisture sensors are installed the DRY light should remain on as dry gas is transported to the analyzer s Turn on the analyzer s and calibrate as required Shutdown Stop sample gas flow to the Universal Analyzers 500 Series The...

Страница 19: ...esigned for maintenance free operation but if any is required ensure power has been removed before maintenance is performed For the best performance of the cooler the following maintenance schedule is recommended Maintenance Activity Frequency Peristaltic pump Replace tubing every 3 months Diaphragm sample pump Replace diaphragm every 6 months Clean heat exchanger Annually Inspect heat sink fins M...

Страница 20: ...ube has dropped below 60 psig at the inlet of the thermal valve Failure of the sample cooler The cooler is not cold enough and needs to be calibrated See calibration procedure below No sample gas flow Heat exchanger plugged Alarm shutoff No power on cooler Check for an obstruction Remove heat exchanger from unit and disassemble Verify Cool Dry Indicators are illuminated Ensure cooler has power sup...

Страница 21: ...ed on the power supply board If the dry light does not illuminate consult the factory Cool light is not illuminated Ambient temperature too high Flow rate water content too high Failed Peltier element Reduce the ambient temperature Increase ventilation or relocate cooler Lower the flow rate through the cooler and observe the results If condition corrects itself consult the factory for further trou...

Страница 22: ...Channel Models 540 570 575 3600 0002 Alarm Relay Circuit Board Single Channel Models 520 530 560 3600 0006 Alarm Relay Circuit Board Dual Channel Models 540 570 575 3600 0007 Power Supply Board 115VAC 250 Watt 15VDC Output 3600 0038 Power Supply Board 230VAC 250 Watt 15VDC Output 3600 0038 230 Spare Parts Optional Parts Part P N Motor Peristaltic Pump 120VAC 6 RPM 4958 0003 Motor Peristaltic Pump ...

Страница 23: ...Page 23 of 44 MAN 500 REVD 06302015 Drawings Model 520 ...

Страница 24: ...Page 24 of 44 MAN 500 REVD 06302015 Drawings Model 530 ...

Страница 25: ...Page 25 of 44 MAN 500 REVD 06302015 Drawings Model 540 ...

Страница 26: ...Page 26 of 44 MAN 500 REVD 06302015 Drawings Model 560 ...

Страница 27: ...VERSAL ANALYZERS INC 5200 Convair Driv e Carson City Nevada 89706 USA P1480 06 08 2009 MODEL 565 SAMPLE COOLER M Jenkins 1 2 CONDUIT PORT SINGLE CHANNEL CONTROLLER POWER SUPPLY ENCLOSURE COOLING FAN UPWARD FLOW 5 INSULATED IMPINGER SAMPLE OUTLET 1 4 TUBE CONDENSATE DRAIN 3 8 NPTF 3 TYP SEE SHEET 2 FOR WIRING SCHEMATIC B 02 24 12 Removed AMP Connector MW RW SAMPLE INLET 3 8 TUBE 1 4 1 3 8 6 13 16 9...

Страница 28: ...Page 28 of 44 MAN 500 REVD 06302015 Drawings Model 570 ...

Страница 29: ...INGERS 2 TYP HEATSINK DUAL CHANNEL CONTROLLER POWER SUPPLY ENCLOSURE 1 2 CONDUIT PORT 2 3 8 4 7 8 14 3 8 A B C D A B C 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 D 8 P0290 07 06 1998 N A REV REVISIONS FOR PART NO E Musselman APVD BY DRAWN BY DRAWING NO DATE NOT ISSUED MODEL 574 SAMPLE COOLER ARRANGEMENT DATE DESCRIPTION DWN APVD SCALE SIZE SHEET NTS D 1 OF 2 UNIVERSAL ANALYZERS INC 5200 Convair Driv e Carson C...

Страница 30: ... SET ALARM RELAY SET S2 YELLOW RED GREEN THERMOCOUPLE INPUT CONTROL TEMP SET POINT ALARM RELAY SET POINT CALIBRATE SPAN CALIBRATE ZERO FAN FAN TB1 TB6 R29 R44 R41 R37 FUSE SLOW BLOW 2 AMP P 3 P 4 P2 P1 P4 P3 P2 P1 DC POWER INPUT Carson City Nevada 89706 USA 1701 S Sutro Terrace UNIVERSAL ANALYZERS INC SINGLE CHANNEL SAMPLE COOLERS SHEET SIZE SCALE DATE B DRAWING NO DRAWN BY APVD BY HARVEY MITCHELL...

Страница 31: ...RO CALIBRATE SPAN ALARM RELAY SET POINT CONTROL TEMP SET POINT THERMOCOUPLE INPUT CHANNEL 1 CHANNEL 2 2 1 3 4 R44 R37 6 1 2 3 4 5 7 8 A B C D 1 2 3 4 5 6 7 A B C D 8 CONTROL BOARD DUAL CHANNEL SAMPLE COOLERS P0024 07 29 92 1 OF 1 1 1 INSTRUMENT APVD DWN DESCRIPTION DATE REV REVISIONS FOR PART NO HARVEY MITCHELL APVD BY DRAWN BY DRAWING NO B DATE SCALE SIZE SHEET NOT ISSUED UNIVERSAL ANALYZERS INC ...

Страница 32: ...RN WHT BLK N L 50 60Hz 115VAC POWER CORD CONTROLLER POWER SUPPLY BOARD CONTACTS PROTECTED WITH 250 VOLT MOV S FAN HEAT EXCHANGER CHASSIS COOL LED ON NORMAL WIRING P0003 04 04 91 1 OF 1 NTS APVD DWN DESCRIPTION DATE REV REVISIONS 1701 South Sutro Terrace UNIVERSAL ANALYZERS INC FOR PART NO HARVEY MITCHELL APVD BY DRAWN BY DRAWING NO B DATE SCALE SIZE SHEET 6 1 2 3 4 5 7 8 A B C D 1 2 3 4 5 6 7 A B ...

Страница 33: ...H 1 10 HP SAMPLE PUMP 32VDC RESISTIVE SHOWN IN DE ENERGIZED WET POSITION SHOWN IN DE ENERGIZED HOT POSITION ALL RELAY CONTACTS UN POWERED DRY CIRCUIT LOWER RELAY BOARD FOR RIGHT HAND SIDE J8 N C 1 ARM1 N O 1 N C 2 ARM2 N O 2 N C 3 ARM3 N O 3 N C 4 ARM4 N O 4 WET DRY DRY WET HOT COLD HOT COLD USER CONNECTIONS TO MOISTURE SENSOR RELAY ENERGIZED WHEN SENSOR IS DRY DRY LED ON RATING 1 10 HP 120VAC 5AM...

Страница 34: ...VD BY DRAWN BY DRAWING NO C DATE SCALE SIZE SHEET SEE TABLE UNIVERSAL ANALYZERS INC 1701 South Sutro Terrace Carson City Nevada 89706 USA SEE TABLE HEAT EXCHANGER OUTLINE THERMOCOUPLE TYPE K TYPE J 5200 SJ50 5200 SJ10 FEMALE FEMALE FEMALE HASTELLOY C276 EXCHANGER P N 5200 CK50 5200 CK10 5200 CJ50 5200 CJ10 ALLOY 20 EXCHANGER P N 5200 AK50 5200 AK10 5200 AJ50 5200 AJ10 400 500 800 1000 1100 3000 UN...

Страница 35: ...BE 5201 0012 5201 0022 SEE NOTES P N 4904 0013 EXPLODED METALLIC HEAT EXCHANGER COMPLETE ASSEMBLY DESC P N ASSY P N 10 10 10 10 10 5 5 5 5 5200 CK50 5200 CJ50 5200 SK10 5200 SJ10 5200 AK10 5200 AJ10 5200 CK10 5200 CJ10 ALLOY 20 HASTELLOY C276 316 S S ALLOY 20 HASTELLOY C276 TYPE K THERMOCOUPLE ASSEMBLY P N TYPE J THERMOCOUPLE ASSEMBLY P N 1150 0011 1150 0012 X X X X X X X X X X X 5201 0020 5201 00...

Страница 36: ...OUTER TUBE MATERIAL UNIVERSAL ANALYZERS SERIES 5 5200 S050 316 S S 400 500 10 5200 S010 316 S S 800 1000 1100 3000 5 5200 C050 HASTELLOY C 276 400 500 5 5200 S05T TEFLON COATED 316 S S 400 500 10 5200 C010 HASTELLOY C 276 800 1000 1100 3000 10 5200 S01T TEFLON COATED 316 S S 800 1000 1100 3000 SECTION B B HEAT EXCHANGER METALLIC NON TEMPERATURE SENSING OUTLINE 1531 12 11 95 1 OF 2 NONE SEE TABLE A...

Страница 37: ...2 5201 0044 10 5200 C010 5201 0021 10 5200 S010 5201 0016 5201 0013 4904 0013 4951 0058 5 5200 S050 5201 0015 5201 0012 4904 0013 4951 0058 APPROX L LENGTH P N INNER TUBE ASSY P N OUTER TUBE ASSY P N VITON O RING 2 021 P N PLUG 1 16 NPT P N 5 5200 C050 5201 0020 5 5200 S05T 5201 0041 5201 0043 15 5200 S015 5201 0107 5201 0055 HEAT EXCHANGER ASSEMBLY NON TEMPERATURE SENSING METALLIC P0147 12 11 95 ...

Страница 38: ...r Temperature Sensing Heat Exchanger Outline UNIVERSAL ANALYZERS INC 1701 South Sutro Terrace Carson City Nevada 89706 USA THERMOCOUPLE TYPE J TYPE K CONDENSATE DRAIN 3 8 NPT INSULATED SECTION 0 300 INSIDE DIAMETER CHILLED SURFACE ANNULAR SPACE 060 WIDE GAS TO BE DRIED RISES IN THIS SPACE SEE TABLE SAMPLE COOLER MODELS ANALYZERS UNIVERSAL 520 530 540 570 1040 1050 1060 1080 1090 GLASS KYNAR HEAT E...

Страница 39: ...ON DATE REV REVISIONS FOR PART NO E Musselman APVD BY DRAWN BY DRAWING NO B DATE SCALE SIZE SHEET SEE TABLE UNIVERSAL ANALYZERS INC 1701 South Sutro Terrace Carson City Nevada 89706 USA Glass Kynar Temperature Sensing Heat Exchanger Spare Parts List Exploded Assembly TYPE K THERMOCOUPLE THERMOCOUPLE TYPE J 5200 KK10 10 5110 2004 5201 0001 5200 KJ10 10 5 1 16 THERMOCOUPLE TEFLON INSULATOR THERMOCOU...

Страница 40: ... COOLER 1 2 2 4 1 2 2 2 4 UNIVERSAL ANALYZERS SAMPLE COOLER MODELS 520 530 540 570 1040 1050 1060 1080 1090 GLASS KYNAR HEAT EXCHANGER ASSEMBLY P N 5200 K050 5200 K010 LENGTH L 5 10 L PLUG 1 16 NPT 1 FGA2 5200 K015 15 1 2 3 4 5 6 7 8 A B C D 1 2 3 4 5 6 7 8 A B C D HEAT EXCHANGER GLASS KYNAR NON TEMPERATURE SENSING OUTLINE P0149 12 11 95 1 OF 2 1 1 INSTRUMENT APVD DWN DESCRIPTION DATE REV REVISION...

Страница 41: ...GS ARE FACTORY INSTALLED IN KYNAR HEAD AND KYNAR DRAIN FITTINGS 2 LIGHTLY LUBRICATE O RINGS WITH SILICONE GREASE BEFORE ASSEMBLY NOTES 7 8 WRENCH FLATS KYNAR INSULATED SECTION ASSEMBLY 5200 K010 10 5110 2004 5201 0001 KYNAR HEAD P N 5201 0017 PLUG 1 6 NPT 1 16 NPT PLUG P N 4951 0066 5200 K015 15 5110 2006 5201 0078 5201 0066 1 2 3 4 5 6 7 8 A B C D 1 2 3 4 5 6 7 8 A B C D HEAT EXCHANGER GLASS KYNA...

Страница 42: ...r liability of UAI arise due to UAI providing technical advice facilities or service in connection with any product There is no warranty by UAI with respect to any product s i uninterrupted or error free operation ii actual performance other than the product s capability to meet UAI s specifications therefor iii removal or installation from a worksite or process iv electronic components or associa...

Страница 43: ...be sent to UAI for inspection unless UAI has authorized Buyer to do so 7 Terms and Conditions UAI s General Terms and Conditions are incorporated herein by reference and Buyer accordingly agrees to be bound by the terms thereof II Limitations on UAI Liability 1 In General Buyer agrees UAI shall not be liable for any direct indirect incidental punitive or consequential damages including lost profit...

Страница 44: ...Page 44 of 44 MAN 500 REVD 06302015 5200 Convair Drive Carson City NV 89706 Phone 775 883 2500 Fax 775 883 6388 www universalanalyzers com ...