 Thank you for choosing our sonic tension meter (U-508).

 We guarantee for one year for the main body and six months for the sensor.

 If our sonic tension meter (U-508) fails due to a manufacturing or workmanship defect  

 during the period, we repair it free of charge.

 Please contact our distributor from which you purchased for the repair. (See the     

 enclosed warranty.)

 When the official approval is required, direct the sensor to a communicator

 which emits stable frequency sound from 10 to 5000 Hz, and measure the same way as 

 measuring tension. The calibration is enabled easily.

 Tension meter official approval device (U-305-OS1) is also in the market.

 If needed, please contact our sales department for paid official approval.

12. Guarantee & Repair Guidelines

About the installation tension level of our tooth belt, the gap will not occur between U-508 measurement and true tension in the range of Note1 
and Note3. So it is not necessary to set a tension compensating rate.
  Note1)As for the measuring installation tension, set the belt on the machine first and measure the average tension of stretch and loose side 
    of the belt after spinning several times to make the machine run smoothly. If both spans have the difference of more than 30%, please 
    adjust them and measure again.
  Note2)Measure with a span having the length more than 20 times the tooth pitch.
    (Because a higher value than actual is showed at the short range to be affected by the rigidity of the belt itself.)
  Note3)Set the tension range more than 1/3 of standard installation tension.
    (Because a higher value than actual is showed at the low tension to be affected by rigidity of belt itself.)
    Also by the measuring method of our tension meter, measurement in an extremely low tension range is sometimes impossible.
  Note4)As for the special belt like a wide and back-ribbed belt on its back for conveying, the gap between the true tension value is presumed, 
    so that simple calibration is required for checking tension which needs comparative precision.

As for experienced machines install the belt following the procedure provided for a corresponding machine, it is capable of managing tension 
by setting cycle numerical value which approved by U-508 afterward.

■ Main Body 

■ Accessories
● U-508

● Option

● Power Supply: Two triple A batteries. Alkaline 
  battery is recommended. 
● Overall Size: 160(H) × 59(W) × 26(26)  

 

● Mass: 120g 
● Temperature and humidity range for use and
  storage: -10〜-50℃, 80% 
  (free from condensation)

11. Specification of U-508

1) Flexible type sensor 
   ・ Sensor outer diameter: 12.5mm
   ・ Total length: 170mm
   ・ Measurable frequency band: 10Hz〜5000Hz 
 

 

 

2) Soft case for carrying   
   ・ Capable of containing the body of tension meter, 
     flexible type sensor etc. 

 

 

   ・ Total length: 170mm
   ・ Measurable frequency band: 10Hz〜5000Hz

3) Two triple A batteries
4) Operation manual of U-508
5) Operating procedure sheet for carrying
6) Inspection acceptance certificate
7) Warranty
8) Two USB connecting caps (one is for a spare)
9) Operating manual of application software for
  U-508
  ※Please use the MINI-B 5 as USB connector

1) Flat flexible sensor
   ・ Sensor outer diameter: Thickness10mm,   
     Width20mm 
   ・ Total length: 170mm
   ・ Measurable frequency band: 10Hz〜5000Hz
2) Long arm sensor
   ・ Sensor outer diameter: 12.5mm 
   ・ Total length: 350mm
   ・ Measurable frequency band: 10Hz〜5000Hz

3) Electromagnetic sensor
   ・ Total length: 1m
   ・ Measurable frequency band: 10Hz〜5000Hz
4) Cord type sensor
   ・ Sensor outer diameter: 12.5mm
   ・ Total length: 1m
   ・ Measurable frequency band: 10Hz〜5000Hz

Содержание U-508

Страница 1: ... mass table of the preinstalled belt 6 2How to input the belt width or the number of belts ribs 6 3How to input the value of span length 8 Unit mass table of Gate Unitta Asia tooth shape timing belt 9 The unit mass table of V belt made by Gates 1 0 The standard installation tension table of the GUA timing belt P9 P1 0 1 1 Specification of U 508 1 2 Guarantee Repair Guidelines P1 2 P11 P10 P1 3 This...

Страница 2: ...nently dangerous situation such as death or severe injury Warning Can cause break down injury and electric shock Caution Injury or physical damages Things the user must NOT do Things the user must do Do not make strong impact or throw Can cause breakdown and fire Do not use this in a flammable environment Can cause an explosion or the fire when using this near propane gas or gasoline Do not break dow...

Страница 3: ...tensile force after confirming the machine has been turned off Even though the arm parts of the sensor are flexible do not bend at an acute angle Please do not bend it close to the head of the sensor within 20mm from the sensor and also do not bend it at the bottom of the sensor Do not grab or twirl the cord strongly Please turn off the power immediately right after you hear a thunder noise and move t...

Страница 4: ... on The unevenness of the output level is large Nothing shows up or only measuring processing sign shows up from the third time of measurin Frequency mode The measured value changes every time greatly The sensor responds to the background noise keenly 0 is entered to the unit mass width span Input the wrong frequency range Measured frequency exceeds 5000Hs Battery drain The sensor attaches to a be...

Страница 5: ...efore U 508 measurement displayed is somewhat higher than the actual tension under the affected condition Therefore it is possible to obtain correction factor by strict calibration test and incorporate it to the data input thereby it can display more accurate tension An example of calibration result of U 508 measurement and actual tension is shown below Calculation To 4 M W S2 f2 1 0 9 To Tension M...

Страница 6: ...utton Change a frequency range 9 UP DOWN button 5 LCD screen with backlight This displays tension value 3 S No 00 M 9 9 9 9 g m W 9 9 9 9 mm R S 9 9 9 9 mm S No 00 2GT TENSION 99900 N Measurement frequency level H HIGH S STANDARD Memory No The measured result In measurement of belt type Battery residual quantity Overview of LCD showing pattern Note This will be shown only from the pre installation...

Страница 7: ...ress SPAN button for putting the width of the belt span numeric key 7 Hz button switching frequency and tension Press Hz button for selecting frequency or tension The mode changes every time this button is pressed Press Hz button more than one second to show both records with tension and frequency 8 0 RANGE button switch frequency range Press 0 RANGE button more than one second to change measureme...

Страница 8: ...sition on display screen by use of numeric key If you input wrong number press MASS button again to return the cursor to the first 0 button PUSH 0 button PUSH 2 button PUSH 5 button PUSH MASS button PUSH holding down more than one second Belt category T V U is shown on screen by pressing MASS button n more than one second By using UP or DOWN button to select the belt category MEASURE button PUSH Be...

Страница 9: ...owever please match indication with tension indication frequency indication when you set the tension level frequency The upper lower limit setting with a PC 8 1 Start measurement Get sensor in central span of the measure object without touching it MEASURE button PUSH LED green blinks shows To vibrate the wire flip the belt span with a finger etc shows The following measurement is performed by the se...

Страница 10: ...ntional type U 303 since the input unit has been changed Therefore when a value is input in conventional unit mass g cm2 measured tension is displayed in 1 10 No change for the measured frequency on the screen 6 2 How to input the belt width or the number of belts ribs Timing or Flat belt To put the date is for belt width is 000 1mm 999 9mm three digits of integer and one digit below decimal point...

Страница 11: ...ut correctly 7 Unit mass table of the preinstalled belt Table2 For U 508 507 and U 505 305 unit mass table Data of unit mass can be input by four significant digits i e three digits of integer and one digit below decimal point in g mm W x m L from 0 1 to 999 9 g mm W x m L 8 Unit mass table of Gate Unitta Asia tooth shape timing belt Note Input with a value 10 times as large as a unit mass listed g...

Страница 12: ... J section 9 0 0 95 8 6 L section 32 0 0 95 30 4 PK section 21 0 0 95 20 0 Input item A 120 0 0 86 103 2 B 200 0 0 83 166 0 C 360 0 0 83 298 8 D 660 0 0 81 534 6 E 1020 0 0 72 734 4 The V belt has high comparative rigidity the gap of revision is necessary for the actual and measured tension value in the range of the standard installation tension Therefore it should be adopted as WEIGHT level which...

Страница 13: ... 5330 7220 20 15 12 21 25 30 36 40 50 62 70 60 80 37 30 20 40 50 60 68 70 80 100 115 90 125 130 Width mm Width2 shape type Tooth Shape MXL 3 2 4 8 6 4 25 31 37 50 75 100 150 200 300 400 500 7 9 9 5 2 9 5 1 7 6 10 3 11 8 16 4 XL L H XH XXH 13 7 19 6 24 5 34 5 55 0 75 1 52 0 87 3 123 0 271 6 198 8 222 312 668 486 909 2020 1430 1120 2480 1750 3190 12 7 19 1 25 4 38 1 50 8 101 6 1030 1050 76 2 127 0 1...

Страница 14: ...tive precision As for experienced machines install the belt following the procedure provided for a corresponding machine it is capable of managing tension by setting cycle numerical value which approved by U 508 afterward Main Body Accessories U 508 Option Power Supply Two triple A batteries Alkaline battery is recommended Overall Size 160 H 59 W 26 26 Mass 120g Temperature and humidity range for ...

Страница 15: ... contact our distributor from which you purchased for the repair See the enclosed warranty When the official approval is required direct the sensor to a communicator which emits stable frequency sound from 10 to 5000 Hz and measure the same way as measuring tension The calibration is enabled easily Tension meter official approval device U 305 OS1 is also in the market If needed please contact our sale...

Страница 16: ...U 508MANUAL V01 HEAD OFFICE 4 26 SAKURAGAWA 4 CHOME NANIWA KU OSAKA 556 0022 JAPAN TEL 06 6563 1284 FAX 06 6563 1285 ...

Отзывы: