background image

Unitronics

 

1

EX-A2X

 

I/O Expansion Module Adapter, Isolated        

 

The EX-A2X interfaces between a variety 
of I/O expansion modules and specific 
Unitronics’ OPLCs. 

A single adapter can be connected to up 
to 8 expansion modules.  

The EX-A2X may either be snap-mounted 
on a DIN rail, or screw-mounted onto a 
mounting plate.

 

Component identification 

1

Status indicators 

2

COM port, EX-A2X to OPLC 

3

Power supply connection points 

4

EX-A2X to expansion module  
connection port 

Before using this product, it is the responsibility of the user to read and understand this document and 
any accompanying documentation. 

All examples and diagrams shown herein are intended to aid understanding, and do not guarantee 
operation.  Unitronics accepts no responsibility for actual use of this product based on these examples. 

Please dispose of this product in accordance with local and national standards and regulations. 

Only qualified service personnel should open this device or carry out repairs. 

User safety and equipment protection guidelines 

This document is intended to aid trained and competent personnel in the installation of this equipment as 
defined by the European directives for machinery, low voltage, and EMC.  Only a technician or engineer trained 
in the local and national electrical standards should perform tasks associated with the device’s electrical wiring. 

Symbol Meaning 

Description 

Danger 

The identified danger causes physical 
and property damage. 

Warning 

The identified danger can cause 
physical and property damage. 

Symbols are used to highlight 
information relating to the user’s 
personal safety and equipment 
protection throughout this document.  
When these symbols appear, the 
associated information must be read 
carefully and understood fully. 

Caution

 Caution 

Use 

caution. 

Failure to comply with appropriate safety guidelines can result in severe personal injury or 
property damage.  Always exercise proper caution when working with electrical equipment. 

www.klinkmann.com

5 / 2011

Содержание EX-A2X

Страница 1: ...ions Only qualified service personnel should open this device or carry out repairs User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in the installation of this equipment as defined by the European directives for machinery low voltage and EMC Only a technician or engineer trained in the local and national electrical standards should pe...

Страница 2: ...s Do not install in areas with excessive or conductive dust corrosive or flammable gas moisture or rain excessive heat regular impact shocks or excessive vibration Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls Do not place in water or let water leak onto the unit Do not allow debris to fall inside the unit during installation M...

Страница 3: ...X A2X Use the communication cable to connect the module s PLC expansion port to the PLC Take care to connect the correct cable The connectors of this cable are housed in yellow insulation Note that one end is marked To PLC and the other To Adapter insert accordingly The module is supplied with a 1 meter cable part number EXL CAB100 Other cable lengths are also available Use only an original Unitro...

Страница 4: ...the power supply Do not connect the Neutral or Line signal of the 110 220VAC to the device s 0V pin In the event of voltage fluctuations or non conformity to voltage power supply specifications connect the device to a regulated power supply Double check all the wiring before turning on the power supply Wiring Procedures Use crimp terminals for wiring use 26 12AWG wire 0 13 mm 2 3 31 mm2 for all wi...

Страница 5: ...upply The EX A2X and the OPLC must be turned on and off simultaneously POWER 0V V EX A2X Technical Specifications I O module capacity Up to 8 I O modules can be connected to a single adapter Power supply 12VDC or 24VDC Permissible range 10 2 to 28 8VDC Max current consumption 650mA 12VDC 350mA 24VDC Typical power consumption 4W Current supply for I O modules 1A max from 5V see Note 1 Galvanic isol...

Страница 6: ... 0 15 The number that represents the I O s location is equal to 32 x 16 y Examples Input 3 located on expansion module 2 in the system will be addressed as I 67 67 32 2 16 3 Output 4 located on expansion module 3 in the system will be addressed as O 84 84 32 3 16 4 EX90 DI8 RO8 is a stand alone I O module Even if it is the only module in the configuration the EX90 DI8 RO8 is always assigned the nu...

Отзывы: