SAFETY NOTES 

 

1.  Open the shipping carton carefully to prevent any accessory, i.e. objectives or eyepieces, from 

dropping and being damaged. 

 

2.  Keep the instrument out of direct sunlight, high temperature or humidity, and dusty environments.   

 

 

 

3.  If any specimen solutions or other liquids splash onto the stage, objective or any other component,  

disconnect the power cord immediately and wipe up the spillage. Otherwise, the instrument may be 
damaged. 

 

4. 

LAMP REPLACEMENT -- CAUTION

:  the glass envelope of the lamp may be extremely 

hot.  DO NOT attempt to change the lamp before it is completely cooled or without 
wearing adequate skin protection.   

 

5.  All electrical connectors (power cord) should be inserted into an electrical surge protector to prevent 

damage due to voltage fluctuations. 

 

6. 

FUSE REPLACEMENT

 -- For safety when replacing the fuse (ONLY replace with the 

same size, type and rating of original fuse), be sure the main switch is in the off position, 
disconnect the power cord from outlet, and replace the fuse.  Reconnect the power cord 
and turn unit on. 

 

7.  Confirm that the input voltage indicated on your microscope corresponds to your line voltage. The 

use of a different input voltage other than indicated will cause severe damage to the microscope. 

 

NOTE:  Always plug the stereomicroscope power cord into a suitable grounded electrical outlet.  A 
grounded 3-wire cord is provided.   

 

 

CARE AND MAINTENANCE

 

1.  Do not attempt to disassemble any component including eyepieces, objectives or focusing assembly. 

 

2.  Keep the instrument clean; remove dirt and debris regularly. Accumulated dirt on metal surfaces 

should be cleaned with a damp cloth. More persistent dirt should be removed using a mild soap 
solution. Do not use organic solvents for cleansing. 

 

3.  The outer surface of the optics should be inspected and cleaned periodically using an air stream from 

an air bulb. If dirt remains on the optical surface, use a soft, lint free cloth or cotton swab dampened 
with a lens cleaning solution (available at camera stores). All optical lenses should be swabbed using 
a circular motion. A small amount of absorbent cotton wound on the end of a tapered stick makes a 
useful tool for cleaning recessed optical surfaces. Avoid using an excessive amount of solvents as 
this may cause problems with optical coatings or cemented optics or the flowing solvent may pick up 
grease making cleaning more difficult.  

 

4.  Store the instrument in a cool, dry environment. Cover the microscope with the dust cover when not 

in use. 

 

5.  UNITRON

®

 microscopes are precision instruments which require periodic servicing to maintain 

proper performance and to compensate for normal wear. A regular schedule of preventative 
maintenance by qualified personnel is highly recommended. Your authorized UNITRON

® 

distributor 

can arrange for this service. 

 

 

 

Содержание Z10

Страница 1: ...73 Mall Drive Commack NY 11725 631 543 2000 P 631 589 6975 F www unitronusa com info unitronusa com Z10 SERIES Z10 Z8 Z6 ZOOM STEREO MICROSCOPES MANUAL ...

Страница 2: ...UNPACKING AND COMPONENTS 4 COMPONENT DIAGRAMS 5 7 ASSEMBLY 8 ADJUSTMENT AND OPERATION ADJUSTING BINOCULAR VIEWING HEAD 12 FOCUS ADJUSTMENT 13 INSTALLING THE BEAM SPLITTER 14 ASSEMBLING THE BEAM SPLITTER VIEWING HEAD CAMERAS 14 INSTALLING THE IRIS DIAPHRAGM 15 OPERATING THE IRIS DIAPHRAGM 15 SPECIFICATIONS 16 TROUBLESHOOTING 17 MAINTENANCE 18 SERVICE 18 WARRANTY 18 ...

Страница 3: ...TE Always plug the stereomicroscope power cord into a suitable grounded electrical outlet A grounded 3 wire cord is provided CARE AND MAINTENANCE 1 Do not attempt to disassemble any component including eyepieces objectives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dirt sho...

Страница 4: ...our staff of trained technicians in our New York facility Careful quality control procedures ensure each microscope is of the highest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if needed Avoid placing the microscope in dusty surroundi...

Страница 5: ...5 Binocular Head Diopter Adjustment Rings Eyepieces Eyepiece Tubes Locking Screw for Viewing Head Locking Screw for Optical Body Optical Body Objective Lens Stage Clips Transmitted Illumination Adjustment Knob Reflected Illumination Adjustment Knob Fine Focus Knob Coarse Focus Knob Zoom Knob LED Stand ...

Страница 6: ...Z10 SERIES STEREO MICROSCOPES UNITRON 73 Mall Drive Commack NY 11725 631 543 2000 www unitronusa com 6 Tilting Ergo Binocular Viewing Head Bonder Arm Ball Bearing Boom Stand ...

Страница 7: ...73 Mall Drive Commack NY 11725 631 543 2000 www unitronusa com 7 Digital Camera C mount Adapter Photo Tube Focus Knob Single Port Beam Splitter Optical Path Selector Knob Iris Diaphragm Stage Plate Locking Screw for Stage Plate Plain Stand ...

Страница 8: ...installed The positions are spaced 55mm apart Should you need to lower the position of the focus mount for the future please follow the following steps 1 Remove the viewing head optical body and objective from the focus mount by loosening the locking screw on the focus mount 2 Using the allen key that was supplied with your stand loosen the allen screw at the rear of the focus mount that connects ...

Страница 9: ...arefully place the optical body into the focus mount and tighten the lock screw to secure the optical body in place 2 Use caution not to over tighten the locking screw as this may cause damage to the instrument Mounting the Objective 1 Using care not to touch the lens surfaces carefully thread the objective into the optical body ...

Страница 10: ... the viewing head into the optical body and secure it into place using a 2mm allen key to tighten the screw Installing the Eyepieces 1 Remove the dust caps from the eyepiece tubes 2 Insert the eyepieces into the eyepiece tube Be sure to install the eyepieces all the way into the tube 3 Set the eyepiece diopter scale for each eyepiece to 0 ...

Страница 11: ...voltage than indicated will cause severe damage to your microscope Connecting the Power Cord Fig 4 Turn the power switch to the off position O before connecting the power cord Insert the power cord plug into the power jack of the microscope make sure the connection is snug Plug the power cord into the power supply receptacle Using the Glass Stage Fig 5 Set the glass stage plate on the center of th...

Страница 12: ...ight fields of view coincide completely and you are able to see a complete circle Adjusting Diopter Ring Focusing Fig 7 Set the diopter rings of both eyepieces to 0 position Do this when users change because different users will have different diopter settings Place an easy to observe specimen on the stage plate i e a coin Rotate the zoom knob to the highest magnification and turn the focusing kno...

Страница 13: ...ise to decrease loosen the focus knob tension After tension adjustment has been completed always rotate both adjustment knobs in the same direction Changing the Magnification The zooming knobs located on both sides of the zooming body will change the magnification of the specimen image Total Magnification Magnification of zoom body x objective x magnification of eyepiece i e 0 8 x 1 0 x 10 8x Movi...

Страница 14: ...ecuring screw of the optical body Tighten the screw to secure the optical body and the beam splitter Install the viewing head on top of the beam splitter and secure it with allen screw Assembling the Beam Splitter Viewing Head Cameras CCD Digital Camera Digital Still Camera Tilting Binocular Head Switch Lens 0 5x c 1x c Digital Still Camera Standard Connecting Tube Digital Still Camera Adapter Bin...

Страница 15: ... diaphragm on top of the optical body tighten the allen screw to secure it into place 4 Mount the eyepiece tube on top of the iris diaphragm and tighten the allen screw to secure it into place Operating the Iris Diaphragm The iris diaphragm is used to enhance the contrast of the image and provide additional depth of field for photography To open the iris diaphragm move the adjusting lever to the l...

Страница 16: ...sual Field mm Total Magnification Visual Field mm Total Magnification Visual Field mm 0 3x 280 2 4X 19 5X 100 12 3 3 6X 29 3X 66 7 8 2 4 8X 39X 50 6 15 0 5X 126 4X 32 5X 60 7 4 6X 52X 40 4 9 8X 65X 30 3 7 1X 78 8X 65X 30 3 7 12X 97 5X 20 2 5 16X 130X 15 1 85 2X 32 5 16X 130X 15 1 85 24X 195X 10 1 23 32X 260X 7 5 0 9 Z10 Series 10 1 Parallel Zoom Body Objective Lens Working Distance mm EYEPIECE WF ...

Страница 17: ...stance is not correct Readjust it page 12 Diopter adjustment is not correct Readjust it page 12 Dirt appears in the view field Dirt on the specimen Clean specimen Dirt on the surfaces of eyepieces Clean eyepieces Image is not clear Dirt on the surface of objectives Clear objectives Image is not clear while focusing change Diopter adjustment is not correct Readjust diopter page 12 Focusing is not c...

Страница 18: ...m defects in material and workmanship for a period of five 5 years for mechanical and optical components and one 1 year for electrical components from the date of invoice to the original end user purchaser This warranty does not cover damage caused in transit misuse neglect abuse or damage resulting from improper servicing or modification by other then UNITRON approved service personnel This warra...

Отзывы: