Unitron UTMD Скачать руководство пользователя страница 5

WARNING 

 
The lives of people depend on your safe installation and 
servicing of UNITROL products.  It is important to read 
and follow all instructions shipped with the products.  In 
addition, listed below are some other important safety 
instructions and precautions you should follow: 
 

Before Installation 

 
       Qualifications 
 

 

To properly install an electronic siren you must have a 
good understanding of automotive electrical 
procedures and systems, along with proficiency in the 
installation and service of safety warning equipment. 

 
         

Sound Hazards 

 

 

Your hearing and the hearing of others, in or close to 
your emergency vehicle, could be damaged by loud 
sounds.  This can occur from short exposures to 
moderately loud sounds.  For hearing conservation 
guidance, refer to federal, state, or local 
recommendations. OSHA Standard 1910.95 offers 
guidance on 

Permissible Noise Exposure.” 

 

 

All effective sirens and horns produce loud sounds, 
which may, in certain situations, cause permanent 
hearing loss.  You should minimize your exposure 
times and wear suitable hearing protection. 

 

During Installation 

 

 

DO NOT

 connect this system to the vehicle battery 

until ALL other electrical connections are made, 
mounting of all components is complete, and you have 
verified that no shorts exist. 

 

 

Be sure the siren amplifier and speaker(s) in your 
installation have compatible wattage ratings. 

 

 

Wire size range from 10 ga (largest) to 20 ga. 

(smallest). Do not use wire that is smaller than any 
vehicle wire being cut apart. Always use a size that 
can safely carry the load to be operated. 

 

 

If Slide Switch outputs may possibly exceed 20 

amps per position, utilize a circuit breaker or relay on 
EACH of the Slide Switch outputs   (Terminal 15, 16 
and 17) 

 
 
 

 

 

Connect all power (not ignition) and ground wires 
directly to battery.  Implementing an in-line switch 
will cause all accessory outputs to energize 
momentarily.  Devices such as gunlocks, trunk release 
etc. will be activated upon power being provided by 
such a switch. 

 

 

Sound output will be severely reduced if any objects 
are in front of this speaker.  If maximum sound output 
is required for your application, you should ensure 
that the front of the speaker is clear of any obstruction. 

 

 

Install the speaker(s) in a location that provides 
maximum signaling effectiveness and minimizes the 
sound reaching the vehicle’s occupants. 

 
1.

 

DO NOT

 install equipment or route wiring or cord in 

the deployment path of an air bag. 

 

 

Locate the siren so the vehicle controls can be 
operated safely. 

 

 

In order for this electronic siren to function properly, 
the ground connection must be made to the 
NEGATIVE battery terminal. 

 

 

When drilling into a vehicle structure, be sure that 
both sides of the surface are clear of anything that 
could be damaged. 

 

 

If wiring is shorted to vehicle frame, high current 
conductors can cause hazardous sparks resulting in 
electrical fires or flying molten metal. 

 

After Installation 
 

 

After installation, test the electronic siren and speaker 
system to ensure that it is operating properly. 

 

 

Test all vehicle functions, including horn operation 
and vehicle light systems, to ensure proper operation. 

 

 

After testing is complete, provide a copy of these 
instructions to the instructional staff and all operating 
personnel. 

 

 

File these instructions in a safe place and refer to 
them when maintaining and/or reinstalling the 
product. 

 

Failure to follow all safety precautions and instructions 
may result in property damage, serious injury, or death to 
you or others. 

SECTION III 

SAFETY MESSAGE TO INSTALLERS OF 

UNITROL SYSTEMS

 

 

 

Содержание UTMD

Страница 1: ...1 I N S T A L L A T I O N M A N U A L TOUCHMASTER DELTA SIREN PA SYSTEM UTMD UTMD MB UTMD AL FS UNITROL 1108 RAYMOND WAY ANAHEIM CA 92801 1 714 871 3336 FAX 1 714 871 3418 22 UTMD 00 ECO 104 06 MAN ...

Страница 2: ...rranty period If such examination reveals a defect in material and or workmanship UNITROL UNITROL will complete the necessary repairs under warranty This warranty does not cover travel expenses the cost of specialized equipment for gaining access to the product or labor charges for removal and re installation of the product Lamps flash tubes or batteries are not covered under warranty Warranty wil...

Страница 3: ...T E N T S SECTION TITLE PAGE I GENERAL INFORMATION 4 II SPECIFICATIONS 4 III SAFETY MESSAGE TO INSTALLERS 5 IV INSTALLATION 6 8 V LATCHING ACCESSORY SWITCHES 8 VI SAFETY MESSAGE TO OPERATORS 10 VII SERVICE AND MAINTENANCE 11 ...

Страница 4: ...ratings Slide bar outputs progressive Position 1___________________________________20 amps Position 2___________________________________20 amps Position 3___________________________________20 amps Progressive total______________________________60 amps Push button switches__________________________20 amps each STANDARD SIREN SOUNDS The TM DELTA is shipped with 5 operational siren sounds MAN manual ...

Страница 5: ...e Slide Switch outputs Terminal 15 16 and 17 Connect all power not ignition and ground wires directly to battery Implementing an in line switch will cause all accessory outputs to energize momentarily Devices such as gunlocks trunk release etc will be activated upon power being provided by such a switch Sound output will be severely reduced if any objects are in front of this speaker If maximum so...

Страница 6: ...aster Delta The Park Kill Module is available at an extra cost The Park Kill Module will protect both the vehicle and the Touchmaster Delta from damage caused by transient voltages See Digital Circuitry Warning NOTE The only wire connected to Terminal 14 should be the GRAY wire of the UPKM 2 When testing this feature put the emergency brake on and verify siren sounds in Reverse and Drive and that ...

Страница 7: ...7 TOP RELAY BOARD ...

Страница 8: ...DE switch is in a siren position WAIL or YELP SECTION V FACEPLATE OPERATION CONFIGURATION SW1 SW2 SW4 SW3 SW6 SW5 TouchMaster Delta auxiliary push button switches Accessory switch connections provide a 12 volt output Hook the power connection of the auxiliary device to the terminal that corresponds to the switch output terminal that operator would like to activate See illustration on next page Swi...

Страница 9: ...9 ...

Страница 10: ...force your way through traffic Your emergency lights siren and actions are REQUESTING the right of way Although your warning system is operating properly it may not alert everyone People may not hear see or heed your warning signal You must recognize this fact and continue driving cautiously Situations may occur which obstruct your warning signal when natural or man made objects are between your v...

Страница 11: ...p is available by phone 7 00 AM to 3 30 PM Pacific Standard Time Monday through Friday except holidays 800 854 3375 is toll free within the United States and Canada Phone 714 871 3336 from other areas If it is necessary to return a unit please observe this procedure a Call for RMA number b Pack to prevent damage in transit c Include brief description of problem and RMA No d Include name and phone ...