MAINTENANCE 

Please remember to 

never

 

leave the microscope with eyepieces removed and always protect the 

microscope with the dust cover when not in use. 

 

 

 

SERVICE 

UNITRON

®

 microscopes are precision instruments which require periodic servicing to keep them 

performing properly and to compensate for normal wear. A regular schedule of preventative maintenance 

by qualified service personnel is highly recommended. Your authorized UNITRON

®

 distributor can 

arrange for this service. Should unexpected problems be experienced with your instrument, proceed as 

follows: 

 

1. Contact the UNITRON

®

 distributor from whom you purchased the microscope. Some 

problems can be resolved simply over the telephone. 

 

2. If it is determined that the microscope should be returned to your UNITRON

®

 distributor or to 

UNITRON

®

 for warranty repair, pack the instrument in its original Styrofoam shipping carton. If you no 

longer have this carton, pack the microscope in a crush-resistant carton with a minimum of three inches 

of a shock absorbing material surrounding it to prevent in-transit damage. The microscope should be 

wrapped in a plastic bag to prevent Styrofoam dust from damaging the microscope. Always ship the 

microscope in an upright position; 

NEVER SHIP A MICROSCOPE ON ITS SIDE

. The microscope or 

component should be shipped prepaid and insured. 

 

 

 

 

 

LIMITED MICROSCOPE WARRANTY 

This microscope is warranted to be free from defects in material and workmanship for a period of five (5) years for 

mechanical and optical components and one (1) year for electrical components from the date of invoice to the original 

(end user) purchaser.  This warranty does not cover damage caused in-transit, misuse, neglect, abuse or damage 

resulting from improper servicing or modification by other then UNITRON® approved service personnel.  This 

warranty does not cover any routine maintenance work or any other work, which is reasonably expected to be 

performed by the purchaser. Normal wear is excluded from this warranty. No responsibility is assumed for 

unsatisfactory operating performance due to environmental conditions such as humidity, dust, corrosive chemicals, 

deposition of oil or other foreign matter, spillage or other conditions beyond the control of Unitron Ltd.  This warranty 

expressly excludes any liability by Unitron Ltd. for consequential loss or damage on any grounds, such as (but not 

limited to) the non-availability to the End User of the product(s) under warranty or the need to repair work processes.  

Should any defect in material, workmanship or electronic component occur under this warranty contact your 

UNITRON® distributor or UNITRON® at (631) 543-2000.  This warranty is limited to the continental United States of 

America.  All items returned for warranty repair must be sent freight prepaid and insured to Unitron Ltd., 73 Mall Drive, 

Commack, NY 11725 –  USA.  All warranty repairs will be returned freight prepaid to any destination within the 

continental United States of America. For all foreign warranty repairs, return freight charges are the responsibility of 

the individual/company who returned the merchandise for repair.   

 

Содержание System 374

Страница 1: ...73 Mall Drive Commack NY 11725 631 543 2000 P 631 589 6975 F www unitronusa com info unitronusa com System 374 ZOOM STEREO MICROSCOPE MANUAL ...

Страница 2: ......

Страница 3: ...PACKING AND COMPONENTS 4 COMPONENT DIAGRAMS 4 5 ASSEMBLY 6 ASSEMBLING THE BALL BEARING BOOM STAND 6 ASSEMBLING THE PLAIN STAND 9 INSTALLING THE BEAM SPLITTER 11 ASSEMBLING THE BEAM SPLITTER VIEWING HEAD CAMERAS 11 ADJUSTMENT AND OPERATION ADJUSTING BINOCULAR VIEWING HEAD 13 FOCUS ADJUSTMENT 14 SPECIFICATIONS 15 TROUBLESHOOTING 16 MAINTENANCE 17 SERVICE 17 WARRANTY 17 ...

Страница 4: ...ope NOTE Always plug the microscope power cord into a suitable grounded electrical outlet A grounded 3 wire cord is provided CARE AND MAINTENANCE 1 Do not attempt to disassemble any component including eyepieces objectives or the focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dirt...

Страница 5: ... microscope is of the highest quality prior to shipment UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if needed Avoid placing the microscope in dusty surroundings or in high temperature or humid areas as mold and mildew can form Carefully remove the microscope fr...

Страница 6: ... 73 Mall Drive Commack NY 11725 631 543 2000 www unitronusa com 5 Ergonomic Binocular Head Eyepieces Zoom Body Lens Objective Focus Mount Focus Knob Ring Light Plain Stand Ring Light Controller Excelis HD Camera Beam Splitter Video Adapter ...

Страница 7: ...en assembling the microscope make sure that all parts are free of dust and dirt and avoid scratching any parts or touching glass surfaces Assembling the Ball Bearing Boom Stand 1 Carefully remove all parts from box and check for all package contents 2 Place the base on the edge of a table as shown below Use the hex bolt to attach the vertical post to the base and tighten using the hex wrench provi...

Страница 8: ...e base on the table and unscrew the cap on the vertical post 4 Insert the safety lock collar onto the vertical post and tighten lock it using the clamp 5 Slide the horizontal pillar with cross block into the vertical post 6 Adjust to the desired position and tighten the cross block on both sides using the 2 knobs ...

Страница 9: ...ce the cap back onto the vertical post 8 Screw the lock lever on the end of the horizontal pillar This lock lever secures the e arm or focus mount 9 Insert the e arm or focus mount into the end of the horizontal bar and tighten using the lock lever 10 Adjust the e arm or focus mount to desired level or position ...

Страница 10: ...unt can be inserted from the TOP BOTTOM or HORIZONTALLY of the horizontal bar Set e arm or focus mount up at various angles and tighten the lock lever for oblique viewing Ball Bearing Boom Stand assembly is complete Assembling the Plain Stand 1 Set the stand flat on a work surface Insert the stage plate into the stand base ...

Страница 11: ...arm to the focus mount with the supplied hex screws Plain Stand assembly is complete Mounting the Zoom Body 1 Carefully place the zoom body into the focus mount and tighten the lock screw to secure the zoom body in place 2 Use caution not to over tighten the locking screw as this may cause damage to the instrument Mounting the Objective 1 Using care not to touch the lens surfaces carefully thread ...

Страница 12: ... Beam Splitter Assembly 1 Insert the viewing head into the beam splitter and secure it into place using a 2mm Allen key to tighten the screw 2 Insert the standard connecting tube into the beam splitter and secure it into place using a 2mm Allen key to tighten the set screw 3 Remove the rubber plug inserted into the C mount on the bottom of the Excelis camera revealing the threads Be careful not to...

Страница 13: ... the eyepieces into the eyepiece tube Be sure to install the eyepieces all the way into the tube 3 Set the eyepiece diopter scale for each eyepiece to 0 Attaching the Ring Light 4 Remove the dust caps from the eyepiece tubes 5 Insert the eyepieces into the eyepiece tube Be sure to install the eyepieces all the way into the tube 6 Set the eyepiece diopter scale for each eyepiece to 0 ...

Страница 14: ...ght fields of view coincide completely and you are able to see a complete circle Adjusting Diopter Ring Focusing Fig 7 Set the diopter rings of both eyepieces to 0 position Do this when users change because different users will have different diopter settings Place an easy to observe specimen on the stage plate i e a coin Rotate the zoom knob to the highest magnification and turn the focusing knob...

Страница 15: ...ise to decrease loosen the focus knob tension After tension adjustment has been completed always rotate both adjustment knobs in the same direction Changing the Magnification The zooming knobs located on both sides of the zooming body will change the magnification of the specimen image Total Magnification Magnification of zoom body x objective x magnification of eyepiece i e 0 8 x 1 0 x 10 8X Movi...

Страница 16: ...PIECE WF 10X Ø24mm Total Magnification Visual Field mm 0 5X 186 4X 25X 60 9 6 1 0X 78 8X 50X 30 4 8 System 374 Trinocular Optical Data MAGNIFICATION Accessory Lens Magnification with Zoom 0 8 FOV mm with Zoom 0 8 Magnification with Zoom 5 FOV mm with Zoom 5 Working Distance 1 0X 23 1X 22 7 148 4X 3 6 78 0 5X 11 5X 45 4 74 2X 7 3 186 1 2 8 CMOS HD camera with 22 monitor and 0 5X video adapter ...

Страница 17: ...stance is not correct Readjust it page 12 Diopter adjustment is not correct Readjust it page 12 Dirt appears in the view field Dirt on the specimen Clean specimen Dirt on the surfaces of eyepieces Clean eyepieces Image is not clear Dirt on the surface of objectives Clear objectives Image is not clear while focusing change Diopter adjustment is not correct Readjust diopter page 12 Focusing is not c...

Страница 18: ... from defects in material and workmanship for a period of five 5 years for mechanical and optical components and one 1 year for electrical components from the date of invoice to the original end user purchaser This warranty does not cover damage caused in transit misuse neglect abuse or damage resulting from improper servicing or modification by other then UNITRON approved service personnel This w...

Отзывы: