INTRODUCTION 

Congratulations on the purchase of your new UNITRON

®

 microscope. UNITRON

®

 microscopes are 

engineered and manufactured to the highest quality standards. Your microscope will last a lifetime if 
used and maintained properly. UNITRON

®

 microscopes are carefully assembled, inspected and tested 

by our staff of trained technicians in our New York facility. Careful quality control procedures ensure each 
microscope is of the highest quality prior to shipment.  
 
The RMM2 Series Rollscopes are portable, compact, metallurgical camera-microscopes designed for 
measuring and photography of inaccessible or large objects that cannot be placed on the stage of an 
ordinary microscope. 
 
RMM2 models can be furnished with optional easy-to-read dial gauges at eye level.  In addition, the 
RMM models have the added feature of built-in graduated rack and pinion X-Y motion to traverse the 
object being studied.  This feature is most desirable when using high-power objectives, as well as in 
choosing and composing areas for photography. 
 
 
 
 

 

UNPACKING AND COMPONENTS 

Your microscope arrived packed in a molded shipping carton. 

Do not discard the carton

:  

the shipping 

carton should be retained for reshipment of your microscope if needed. Avoid placing the microscope in 
dusty surroundings or in high temperature or humid areas as mold and mildew can form. Carefully 
remove the microscope from the shipping carton and place the microscope on a flat, vibration-free 
surface.  

 

Unless you have specified otherwise, the RMM2 Rollscope is furnished with the following: 

 

EYEPIECE:

  10x Widefield high eyepoint 

 
 

MICROMETER RETICLE: 

 Installed in eyepiece; engraved scale; 10mm with 0.1mm divisions or 0.4 inch 

with 0.01 inch divisions depending upon model selected 
 
 

ILLUMINATOR:

  Vertical illuminator with condenser system, diaphragm, filter holder and two knurled 

screws. Two filters (yellow and green) are included to enhance contrast. The knurled centering screws 
are used to adjust the position of the bulb for optimum illumination. Also included are two types of bulb 
socket and cord assemblies; one is used for AC operation with the transformer and the other is for DC 
operation with batteries. 
 
 

OBJECTIVES: 

 Plan achromat 5x, 10x, 20x & 50x 

 
 

 

Содержание RMM2

Страница 1: ...73 Mall Drive Commack NY 11725 631 543 2000 P 631 589 6975 F www unitronusa com info unitronusa com RMM2 ROLLSCOPE MICROSCOPE MANUAL ...

Страница 2: ... 631 543 2000 www unitronusa com 2 CONTENTS SAFETY NOTES 3 CARE AND MAINTENANCE 3 INTRODUCTION 4 UNPACKING AND COMPONENTS 4 COMPONENTS DIAGRAM 6 ASSEMBLY 7 OPERATION 7 PHOTOMICROGRAPHY 10 ADJUSTMENT AND CARE 11 SPECIFICATIONS 12 MAINTENANCE 13 SERVICE 13 WARRANTY 13 ...

Страница 3: ...OTE Always plug the stereomicroscope power cord into a suitable grounded electrical outlet A grounded 3 wire cord is provided CARE AND MAINTENANCE 1 Do not attempt to disassemble any component including eyepieces objectives or focusing assembly 2 Keep the instrument clean remove dirt and debris regularly Accumulated dirt on metal surfaces should be cleaned with a damp cloth More persistent dirt sh...

Страница 4: ...power objectives as well as in choosing and composing areas for photography UNPACKING AND COMPONENTS Your microscope arrived packed in a molded shipping carton Do not discard the carton the shipping carton should be retained for reshipment of your microscope if needed Avoid placing the microscope in dusty surroundings or in high temperature or humid areas as mold and mildew can form Carefully remo...

Страница 5: ...t photographs are being made PLANE GLASS REFLECTOR No adjustment is necessary to provide ideal conditions for vertical illumination The plane glass reflector has been factory installed adjusted and inspected and is correctly positioned to assure even full field illumination No positioning change is required before use unless the reflector has been disturbed in transit assembly or usage DIAL DEPTH ...

Страница 6: ...icrometrics Digital Camera Depth Gauge Depth Gauge Bracket With Lock Screw X Axis Control Graduated Positioning Scale Fine Focus Knob Roll Feet Contact Screw Vertical Illuminator Not shown Bulb cord and socket assembly Bulb Centering Screws Y Axis Control Coarse Focus Knob Field Diaphragm Control Lever Illuminator Filter Slot Objectives Nosepiece Optional Accessory ...

Страница 7: ...life In general use higher illumination intensities to provide short exposure times during photography or for examining poorly reflecting materials Always turn the transformer off when the microscope is not in use Operation With Batteries The illuminator may be operated by batteries for completely portable operation NOTE Insert the metal battery spacer into each foot before inserting the batteries...

Страница 8: ... tightened or loosened The bulb position is optimum when the filament image appears as shown in Figure C below Figures A and B illustrate an off centered filament Lamp Filament Alignment 2 Referring to the figure above note that there are three conditions to be met a The full square area of the filament should be seen This is obtained by rotating the bulb socket in the sleeve of the centering adju...

Страница 9: ...imen is in sharp focus A slight adjustment with the fine focus knob may be necessary when changing objective power Changing Objective Magnifications Total magnification is the product of the eyepiece power multiplied by the power of the objective The objectives are parfocal Therefore once an image is in sharp focus only a slight adjustment of the fine focus control will be needed when rotating the...

Страница 10: ...auge reading gives a direct measurement of the difference in height between the two levels The highest measuring accuracy will be obtained by using the 50x objective since this objective has the smallest depth focus NOTE This procedure is not necessary with the digital depth gauge X Y Motion The RMM2 Series is equipped with a built in mechanical bench which slides the microscope body in X Y direct...

Страница 11: ...t cover The eyepiece should always be in the microscope to eliminate the possibility of dirt or dust from entering the vertical tube and falling onto the back lenses of the objectives Should the optics require cleaning only use the finest grade of soft camera lens tissue If foreign matter or stubborn dirt has adhered to a lens surface a small amount of xylene applied sparingly can be applied with ...

Страница 12: ...tor Variable 6 volt 20 watt Koehler type vertical halogen illuminator with field diaphragm for both AC and DC operation Filters Green and yellow filters are standard A filter slot is built into the illuminator housing Dimensions Weight Physical weight dimensions 9 lbs 9 x 11 x 10 WDH Shipping weight and dimensions 28 lbs 21 x 14 x 16 Warranty 5 year limited warranty instruction manual and dust cov...

Страница 13: ...defects in material and workmanship for a period of five 5 years for mechanical and optical components and one 1 year for electrical components from the date of invoice to the original end user purchaser This warranty does not cover damage caused in transit misuse neglect abuse or damage resulting from improper servicing or modification by other then UNITRON approved service personnel This warrant...

Отзывы: