Error messages
Message
Explanation
Solution
1
Hardware malfunction on subpart nr.#{subcode}
Hardware problem.
If this error persists after reboot, Contact
manufacture.
2
Internal communication failure on subpart
nr.#{subcode}
Communication issue between components on
the board.
3
Temperature is again below the critical value on subpart
nr.#{subcode}
Temperature of part is below critical value
again.
Check if device has appropriate cooling.
4
Temperature exceeds the critical value on subpart
nr.#{subcode}
Temperature of part is above the critical value.
5
Current overload solved on the input #{subcode}
Current from module to external LNB on input is
ok again.
Check if the load on the input does not
exceed the recommended 0,3A.
6
Current overload on the input #{subcode}
Current from module to external LNB on input is
in overload protection mode, LNB is not
powered anymore.
7
Input undervoltage lockout solved on the input
#{subcode}
Voltage from module to external LNB on input is
ok again.
8
Input undervoltage lockout on the input #{subcode}
Voltage from module to external LNB on input is
in protection mode, LNB not powered anymore.
9
Input #{subcode} thermal shutdown solved
Module LNB power supply has recovered from
thermal shutdown, external LNB on input is ok
again.
10
input #{subcode} thermal shutdown
Module LNB power supply is in thermal
shutdown, external LNB on input not powered
anymore.
11
Input signal available on tuner #{subcode}
12
Input signal lost on tuner #{subcode}
Check if signal is connected and LNB
powered when needed.
13
Too low input signal solved on tuner #{subcode}
Signal level has gone from low level to
acceptable level.
Check the input cabling/equipment if the
signal is entering the device with an
appropriate level.
14
Input signal too low on tuner #{subcode}
15
Too high input signal solved on tuner #{subcode}
Signal level has gone from a to high level to an
acceptable level.
16
Input signal too high on tuner #{subcode}
17
Input signal quality good on tuner #{subcode}
18
Input signal quality too low on tuner #{subcode}
Signal quality is not so good.
19
Output bitrate on mux #{subcode} again under the
upper limit
20
Output bitrate on mux #{subcode} exceeds the upper
limit
There are too many services in the output mux,
there is an overflow from time to time image on
tv set can show blocks.
Decrease the amount of services in the
mux.
21
System overflow solved on #{pipe}
22
System overflow on #{pipe}
The bitrate on the indicated fifo exceeds the
maximum value.
Decrease the amount of services on the
indicated fifo. Contact manufacture.
23
CAM module #{subcode} initialization is fixed
24
The CAM module #{subcode} initialization failed
Check if CAM module is ok, try to reboot
the CAM module.
25
CAM#{subcode} bitrate OK
26
CAM #{subcode} bitrate exceeds the upper limit
There are too many services assigned to the
indicated CAM path.
Decrease the amount of services on the
indicated CAM.
27
MPTS #{subcode} input stream was found out
28
MPTS #{subcode} input stream lost
The device was not able to process the
information tables of the transponder.
Try to retune the tuner and check if