Unitron 9732MC Скачать руководство пользователя страница 4

dCSS/dSCR Multiswitch (Ref. 9732MC) v1.0 

 

 

 

 

 

4

 

 

 

 

2.

 

C

ONFIGURATION OF THE MODULE

 

Installation Mode 

The device starts up in installation mode to check the equipment functionality and the correct 
installation. In this mode the automatic gain control is frozen (commands for activating the 
AGC are required). The multiswitch switches to SCR/CSS mode upon receiving a DiSEqC 
message. 
To activate one or more of the UBs a proper DiSEqC message should be received. 

The installation mode starts up with the following 2 transponders active (both output signals 
are having a fixed gain): 

 

Transponder 58 (Frequency: 11880 Vertical) placed in output IF 1281. 

 

Transponder 101 (Frequency: 12731 Horizontal) placed in output IF 2131. 

 

CSS Mode 

ONLY EN50494/SCR standard 

For Installation with Legacy STB and PVR SCR compatible: 

 

Max 8 User Bands (UB0 to UB7) available (as in the LNB SCR) 

 

Signalling DiSEqC 1.0 

ONLY EN50607/dCSS standard 

For NEW Installation of HMG: 

 

16 User Bands for HMG in the range from UB0 to UB15 

 

Signalling DiSEqC 1.0 or 2.0 

CONCURRENT EN50494/EN50607 standards 

For existing MULTIVISION installations (Legacy STB/PVR SCR compatible), with main STB 

upgraded to Next Gen PVR/HMG: 

 

Max 8 User Bands (UB0 to UB7) available for current STB/PVR 

 

16 User Bands for HMG in the range from UB0 to UB15 

 

Signalling DiSEqC 1.0 + signalling DiSEqC 2.0 in the same cable from LNB to apartment 

 

 

Содержание 9732MC

Страница 1: ...User Manual dCSS dSCR Multiswitch 9732MC ...

Страница 2: ...t of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron cannot be held liable for any damages resulting from the use of this product Specifications are subject to change without notice 1 17 Unitron Frankrijk...

Страница 3: ...dCSS dSCR Multiswitch Ref 9732MC v1 0 3 1 INSTALLATION OF THE HARDWARE ...

Страница 4: ...r 58 Frequency 11880 Vertical placed in output IF 1281 Transponder 101 Frequency 12731 Horizontal placed in output IF 2131 CSS Mode ONLY EN50494 SCR standard For Installation with Legacy STB and PVR SCR compatible Max 8 User Bands UB0 to UB7 available as in the LNB SCR Signalling DiSEqC 1 0 ONLY EN50607 dCSS standard For NEW Installation of HMG 16 User Bands for HMG in the range from UB0 to UB15 S...

Страница 5: ...e Female dCSS dSCR UBs 16 16 dCSS dSCR output level 85 dBµV Return loss 8 dB Typ 12 dB Tap loss Not applicable AGC automatic Gain control Band and polarity selection DiSEqC 1 0 unidirectional DiSEqC 2 0 bidirectional Standard EN 50494 SCD Standard EN 50607 SCD 2 Max DC current consumption 320mA 13 Volt Power supply From STB power inserter or trunk VL Power inserter 2460 9669 available separately 3...

Страница 6: ...0 40 EN50494 4 1006 40 EN50494 5 1057 40 EN50494 6 1108 40 EN50494 7 1159 40 EN50494 0 1210 40 EN50607 HMG 16 tuners 1 1420 40 EN50607 2 1680 40 EN50607 3 2040 40 EN50607 4 1006 40 EN50607 5 1057 40 EN50607 6 1108 40 EN50607 7 1159 40 EN50607 8 1261 40 EN50607 9 1312 40 EN50607 10 1363 40 EN50607 11 1471 40 EN50607 12 1522 40 EN50607 13 1573 40 EN50607 14 1624 40 EN50607 15 1731 40 EN50607 ...

Страница 7: ...lation Do not place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes Do not place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climates not in tropical climates Respect the minimum and maximum temperature specifications To avoid any risk of electri...

Страница 8: ... product out of its specifications Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF P...

Отзывы: