![Unitek TV3.230 Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/unitek/tv3-230-series/tv3-230-series_manual_4039349025.webp)
5 Adjustment
TV3.2
25
A
ct
u
a
lV
a
lu
e
Speed actual value
DC-tachometer generator
Connection
input X1:7
= tacho (GND )
input X2: 8
= tacho ( Signal)
PE-bolt
= screen
nominal value input X1: 4 positive
>>> tacho input X2: 8 positive
Tacho voltage
with maximum speed
limit values
>>> minimum 7V=, maximum 20V=
Pre-adjustment
with external resistor R
TG
= tacho voltage x 1.2 -8
TG
Fine adjustment
with potentiometer n
max
(P2)
nominal value of potentiometer:
adjust with 1V nominal value to 10% maximum speed
adjust finely with 10V nominal value to 100%.
nominal value of CNC\SPS:
adjust with 0.8V nominal value to 10% maximum speed
Armature voltage control
only with isolation amplifier ( UNITEK QTV)
Change direction of rotation
change nominal value connection X1:4, X1:6
or
change motor and nominal value connection
Содержание TV3.230 Series