Basic
information
Classic Q1
6
Sp
ecificati
o
n
s
2.4
Specifications
Common specification
Mains frequency
50 or 60 Hz ±5 %
Protection rating
IP 00
Format
VDE 0100 group C / VDE 0160
Humidity rating
Class F acc. to DIN 40040
Site of installation
< 1000m above sea level
Operating temperature range
0 ... 45°C
Extended operating range
up to 60°C reduced by 2%/°C
Storage temperature range
-30°C to + 80°C
Amplification
Input signal
0… ± 10 V
=
Output
0… ± 200 % type current
Enable
> + 10 Volt
Current control loop circuit
Control precision
± 2 %
Control range
1:50
Over-current limiting
10 Sec. 200 % type current
Speed control loop circuit
(see MANUAL REG)
Control precision (without actual value error)
± 0.1 %
Control range
> 1:300
2.5
Interfaces
Interface control electronics X3
Function
Connector no.
+ 24 V
±10 %
X3: 1 and 2
+ 15 V
±2 %
X3: 3 and 4
- 24 V
±10 %
X3: 5 and 6
- 15 V
±2 %
X3: 7 and 8
Device zero GND
0
X3: 9, 10, 11, 12, 13, 14
l – command value (GND)
0
X3: 15
l – command value (signal)
+10 V
=
X3: 16
Current controller enable
+10 V
=
X3: 17
Disable 1
+10 V
=
X3: 18
Disable 2
+10 V
=
X3: 19
Not connected
not connected
X3: 20
I (current) actual
±5 V
=
X3: 21
Over-current power section
+10 V
=
X3: 22
Ignition angle 1
+ 10 V
=
X3: 23
Ignition angle 2
+10 V
=
X3: 24
Drive ready BTB
+10 V
=
X3: 25
Not connected
not connected
X3: 26