DOC. NO.
:
Page 10
The Set Function format (from PC to Monitor) is
Name
Length
Command
Value1
Value2
Value3
CR
Byte Count
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte
Bytes order
1
2
3
4
5
6
And the acknowledge signals are defined as:
Acknowledge Signal
Value
CR
1 Byte
1 Byte
Receive a valid command
‘+’
(0x2B)
CR
(0x0D)
Receive a non-valid command
‘-‘
(0x2D)
CR
(0x0D)
Example of set functions:
Set
Power Off
Command (ASCII):
Name
Length
Command
Value1
Value2
Value3
CR
Byte Count
‘5’
(0x35)
‘|’
(0x21)
‘0’
(0x30)
‘0’
(0x30)
‘0’
(0x30)
CR
(0x0D)
Bytes order
1
2
3
4
5
6
The monitor will reply
Name
ACK
CR
Byte Count
‘+’
(0x2B)
CR
(0x0D)
Bytes order
1
2
Set
Power On
Command (ASCII):
Name
Length
Command
Value1
Value2
Value3
CR
Byte Count
‘5’
(0x35)
‘|’
(0x21)
‘0’
(0x30)
‘0’
(0x30)
‘1’
(0x31)
CR
(0x0D)
Bytes order
1
2
3
4
5
6
The monitor will reply
Name
ACK
CR
Byte Count
‘+’
(0x2B)
CR
(0x0D)
Bytes order
1
2
Содержание UniSign-3812A
Страница 6: ...DOC NO Page 6 1 5 Absolute Ranges of Environment...
Страница 7: ...DOC NO Page 7 2 Electrical Specifications 2 1 Electrical Block Diagram 2 2 Connecter Pin Assignment...
Страница 17: ...DOC NO Page 17 4 Mechanical Specifications...
Страница 21: ...DOC NO Page 21 6 3 Control Keypad Key Function Supported Up Down Right Set Lift Menu Quit Source Power...
Страница 28: ...DOC NO Page 28 7 Packing 7 1 Product Label Definition 65 65mm Product Label Position...
Страница 29: ...DOC NO Page 29 7 2 Carton Label Definition 65 65mm Carton Label Position...
Страница 30: ...DOC NO Page 30 7 3 Cartons Specifications...
Страница 31: ...DOC NO Page 31 7 4 Carton Packing...
Страница 32: ...DOC NO Page 32 7 5 Pallet Specifications...