background image

I. Notes 

Notes: 

*The  air  conditioning  is  only  suitable  for  indoor  use,  and  is  not  suitable  for  other 
applications. 

*Follow local grid interconnection rules while installing the air conditioning and ensure 
that it is properly grounded. If you have any question on electrical installation, follow 
the instructions of the manufacturer, and if necessary, ask a professional electrician to 
install it.   

*Place the machine in a flat and dry place and keep a distance of above 50cm between 
the machine and the surrounding objects or walls. 

*After the air conditioning is installed, ensure that the power plug is intact and firmly 
plugged into the power outlet, and place the power cord orderly to  prevent someone 
from being tripped or pulling out the plug. 

*Do not put any object into the air inlet and outlet of the air conditioning. Keep the air 
inlet and outlet free from obstructions.   

*When  drainage  pipes  are  installed,  ensure  that  the  drainage  pipes  are  properly 
connected, and are not distorted or bended. 

* While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with 
hands gently to avoid damaging wind-guide strips. 

*When moving the machine, make sure that it is in an upright position.   

*The machine should stay away from gasoline, flammable gas, stoves and other heat 

sources.   

*  Don't  disassemble,  overhaul  and  modify  the  machine  arbitrarily,  otherwise  it  will 
cause a machine malfunction or even bring harm to persons and properties. To avoid 
danger, if a machine failure occurs, ask the manufacturer or professionals to repair it. 

*  Do  not  install  and  use  the  air  conditioning  in  the  bathroom  or  other  humid 
environments.   

* Do not pull the plug to turn off the machine. 

* Do not place cups or other objects on the body to prevent water or other liquids from 
spilling into the air conditioning. 

*Do not use insecticide sprays or other flammable substances near the air conditioning. 

* Do not wipe or wash the air conditioning with chemical solvents such as gasoline and 
alcohol. When you need to clean the air conditioning, you must disconnect the power 
supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with 
a mild detergent.   

Содержание UPC-8027

Страница 1: ...INSTRUCTIONS MANUAL UPC 8027 PORTABLE AIR CONDITIONER Read and save these instructions for future reference ...

Страница 2: ... and Adjustment IV Control Setting V Drainage Instructions VI Maintenance VII Troubleshooting VIII Appendix Thank you for choosing the luxurious and elegant mobile air conditioning Please keep the manual for later review and read the manual carefully before use ...

Страница 3: ...orted or bended While adjusting the upper and lower wind guide strips of the air outlet pluck it with hands gently to avoid damaging wind guide strips When moving the machine make sure that it is in an upright position The machine should stay away from gasoline flammable gas stoves and other heat sources Don t disassemble overhaul and modify the machine arbitrarily otherwise it will cause a machin...

Страница 4: ...ned machine aristocratic atmosphere With cooling dehumidification and fan function Continuous Water Drainage Functions LED displays the control panel The machine is beautiful and elegant High quality remote control is equipped to facilitate operation It adopts a user friendly remote control design Outdoor interface is set high to facility assembly and keep the smooth flow of the heat pipe Air filt...

Страница 5: ...ght position and the air conditioning should be placed on a flat surface Do not install and use the air conditioning in the bathroom or other humid environments 1 1 Install the heat pipe assembly as shown in Fig 1 screw the heat pipe assembly exhaust fitting end into the exhaust port on the rear panel Front Housing Handle Rear Housing EVA Filter Continuous Drainage Hole Air Vent CON Filter Drainag...

Страница 6: ... the window sealing plate assembly open adjust their opening distance to bring both ends of the assembly into contact with the window frame and fix various components of the assembly 1 2 Install the window sealing plate assembly 1 3 Install the body 1 Move the machine with installed heat pipe and fittings before the window and the distance between the body and walls or other objects shall be least...

Страница 7: ... exhaust pipe not blocked Important Notice The length of the exhaust hose shall be 280 1 500mm and this length is based on the specifications of the air conditioning Do not use extension tubes or replace it with other different hoses or this may cause a malfunction Exhaust host must be not blocked otherwise it may cause overheating IV Control Panel Setting I Operating instructions LED Control Pane...

Страница 8: ...up key or down key to select the required time 5 Wind Speed Selection Key In cooling and fan mode press the key to select high or low wind speed operation But limited by anti cold conditions under certain conditions it may not run according to the set wind speed In dehumidifying mode pressing the key is invalid and the fan will forcibly choose low wind speed operation 6 Timing Key In the case of p...

Страница 9: ...ch between cooling fan dehumidifying mode 5 Up press the key to increase temperature and timing set value 6 Fan press the key to select high low wind speed 7 Sleep Mode Press the key to turn on the sleep mode III A Variety of Protection Functions 3 1 Frost Protection Function In cooling dehumidifying or economic power saving mode if the temperature of the exhaust pipe is too low the machine will a...

Страница 10: ...or it has a 3 minute delay booting protection function after the compressor is turned off V Drainage Instructions 1 Manual drainage 1 When the machine stops after the water is full turn off the machine power and unplug the power plug Notes Please move the machine carefully so as not to spill the water in the water pan at the bottom of the body 2 Place the water container below the side water outle...

Страница 11: ...ehumidifying mode as shown in figure 1 Unscrew the drainage cover and unplug the water plug 2 Set the drainage pipe into the water outlet 3 Connect the drainage pipe to the bucket VI Maintenance Cleaning before cleaning and maintenance turn off the machine and unplug the plug 1 Clean the surface Clean with surface of machine with a wet soft cloth Don t use chemicals such as benzene alcohol gasolin...

Страница 12: ...ater plug and discharge the water in the water pan into other water containers or directly tilt the body to discharge the water into other containers 2 Turn on the machine adjust it to low wind ventilation mode and maintain this state until the drainage pipe becomes dry so as to keep the inside of the body in a dry state and prevent it from mildewing 3 Turn off the machine unplug the power plug an...

Страница 13: ...nt temperature of greater than 17 62 The cooling effect is not good There is direct sunlight Pull the Curtain Doors or windows are open there are a lot of people or in cooling mode there are other sources of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air inlet or outlet is blocked Clear obstructions Big Noise The air ...

Страница 14: ...nded solutions do not work please contact the professional service organization Appendix Fuse Parameters Type FSD or 50F Voltage 250V Current 3 15A Schematic Diagram All the technical and specific parameters please refer to product nameplate Due to continuous improvement we reserve the right to change some design without any notice Treatment Don t put the abandoned machine with other unsorted wast...

Страница 15: ...parate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith Amiridis Savvidis S A states that this product complies with the requirements of below directives EMC Directive 14 30 EU Low Voltage Directive 14 35 EU ErP Directive 09 125 EC CE Marking 93 68 EEC RoHS Directive 11 65 EU The detailed declara...

Отзывы: