4.
IMPORTANT TEST for leaks: This must be carried out in a well-ventilated area, free from
any open flames or other sources of ignition. With the regulator connected to the cylinder,
turn on the gas cylinder valve 1 and 1/2 turns anti-clockwise. Brush all hose connections,
pipe connections to the gas valve, regulator connection to the cylinder and gas cylinder
valve with a 50:50 solution of detergent and water. A stream of bubbles forming is an
indication of a leak. If a leak is found, turn off the cylinder valve (clockwise), disconnect
the regulator from the gas cylinder and remove the gas cylinder to a cool, outdoor well-
ventilated area. Contact your dealer or gas supplier for assistance.
DO NOT USE THE HEATER IF A LEAK IS FOUND.
DO NOT USE A NAKED FLAME FOR LEAK TESTING.
DO NOT OPERATE ANY ELECTRICAL EQUIPMENT IN THE PRESENCE OF A GAS
LEAK.
5. After leak-testing has passed, fit the rear panel onto the heater. It may be necessary to
twist the cylinder slightly to allow the regulator and hose to fit inside the back panel
without kinking the hose.
Lighting Instructions:
The heater can be regulated to three different settings: 1-LOW, 2-MEDIUM and 3-HIGH.
Ignition mode: piezo ignition.
● Open the valve on the heater cylinder 1 and 1/2 turns.
● Press down and turn the control knob to 1-LOW position and hold for 10 seconds.
● While still pressing down the pilot light, press once or twice on the ignition button
until the pilot light (at the bottom of the burner) ignites. Continue to hold the
control knob down for 10-15 seconds more. Release the button, and if the pilot
flame goes out, repeat the above operation.
Note: when lighting a new heater for the first time, it might be necessary to hold the control
knob down for longer time in order to allow gas to flow to the pilot.
Once the heater is on at the 1-LOW setting, turn the control knob to 2-MEDIUM or 3-HIGH
position in order to light the second and third panel respectively.
To turn off the heater, turn back the control knob to the OFF position and close the cylinder
valve fully (clockwise).
The heater
can only
be turned
off
by closing the cylinder valve. It
can not be turned off by the control knob.
Changing the cylinder:
Turn off the cylinder valve fully (clockwise) and allow the heater to fully cool before removing
and replacing the cylinder. Do not attempt to remove the regulator while the heater is still
running.
Содержание UHG-842