© 201
6
Enviro Water Solutions,
LLC
3060 Performance Circle, Suite 2, DeLand, FL 32724
Page 8
(855) 498-0023
United Water Filter
WR
10/PS15
Premium Whole House Water Filter
/Conditioner
Rev A
Carbon
Flush
!IMPORTANT!
Do not perform the Carbon
Flush
until the Carbon Soak process is complete.
Notice:
Water will flow out of the
outlet
side of the Bypass Valve during this process. Be sure you perform this
series of steps in a location suitable for water flow.
Figure 4
1.
Reattach the garden hose to the Hose Bib Assembly.
2.
Slowly turn on the water
less than a 1/4 turn on the hose spigot
for this entire process.
3.
Run water through the
inlet side of the Bypass Valve for
30 minutes
to expel the carbon fines.
4.
Turn off the water.
5.
Remove the Hose Bib Assembly from the inlet side and attach it to the
outlet
side
of the Bypass Valve.
6. Slowly, fully open the hose spigot.
7.
Run the water through the
outlet
side for
3
minute
s
to reset the carbon.
8.
Turn off the water.
9.
Remove the Hose Bib Assembly from the Bypass Valve and disconnect the garden hose.
Note:
Please save the Hose Bib Assembly as this will be used in the future for the carbon
replacement.
Water
Bypass Valve
Whole House Water Filter
/Conditioner
Garden
Hose
Hose Bib
Assembly
OUTLET
INLET
INLET
Water
Bypass Valve
Whole House Water Filter
/Conditioner
Garden
Hose
Hose Bib
Assembly
OUTLET
Figure
5
Carbon Reset
Carbon Flush
Содержание PS15
Страница 1: ...Owner s Manual Whole House Water Filter Conditioner Models WR10 PS15 ...
Страница 16: ......
Страница 18: ......
Страница 20: ......