Note :   

·

Place the machine on flat ground, and keep it far from around things at least 50cm.   

·

Make sure the socket can be reached from machine location.     

·

Keep the machine stand upright so that compressor can work well.   

·

Don’t run the machine near to gasoline or any other flammable liquids. 

·

Make sure free access of air-inlet and air-outlet. 

·

Don’t use spraying agent (such as pesticides , paint) or other flammable materials, 

otherwise plastic deformation, or even electric damage of the machine may be 

caused.     

 

Power supply 

·

  Make sure no damage in plug. 

·

  Don’t use connector instead of plug. 

·

  Insert plug into socket first, then turn on socket switch , press key “POWER” to run 

machine.

 

 

Please safekeep this user’s manual. 

   

Placement and Installation   

Placement 

·

Place the machine on flat and dry ground, and keep it far from around things at least 

50cm. (fig.1)

 

                                       

                      (fig.1) 

Содержание PAC-9028

Страница 1: ...USER S MANUAL PAC 9028 PORTABLE AIR CONDITIONER ...

Страница 2: ...er s manual carefully before using the machine Any problem please contact the professional service for help CONTENTS IMPORTANT SAFEGUARDS 3 PLACEMENT AND INSTALLATION 4 PARTS NAME 6 CONTROL PANEL 7 REMOTE CONTROL 8 OPERATION METHODS 9 WATER DRAINAGE 10 MAINTENANCE 10 TROUBLE SHOOTING 12 ...

Страница 3: ...e plug when the machine is under cleaning parts replacement or leaving unused Please clean the machine based on the instruction in user s manual Please make sure using voltage meet requirements the damages caused by connection error is out of the scope of warranty Don t let little children touch the machine Don t run the machine when no one there even if a short leave please turn off it Don t tug ...

Страница 4: ... and air outlet Don t use spraying agent such as pesticides paint or other flammable materials otherwise plastic deformation or even electric damage of the machine may be caused Power supply Make sure no damage in plug Don t use connector instead of plug Insert plug into socket first then turn on socket switch press key POWER to run machine Please safekeep this user s manual Placement and Installa...

Страница 5: ...Errors Free access of exhaust pipe is important installation errors will bring bad influence of machine Avoid exhaust pipe with sharp bend fig 3 Make sure air in exhaust pipe can run smoothly fig 4 fig 3 fig 4 Warning Length of exhaust pipe according to the machine features please don t replace or lengthen it freely otherwise errors will be easily caused Note extreme length of unfolding exhaust pi...

Страница 6: ...ack Side fig 6 5 Filter frame upper 6 Exhaust Connector 7 Filter frame lower 8 Rubber plug 9 Plug cap 10 Power Cord Check packing accessories read user s manual to get how to use them fig 4 fig 4 1 Exhaust hose 2 Ajustable slide bar 3 Slide bar connector 4 Remote control fig 5 fig 6 ...

Страница 7: ...OWN under cooling mode press this key to downward setting temperature from 16 31 5 UP under cooling mode press this key to upward temperature from 16 31 6 SLEEP under cooling mode press this key to turn on off sleeping function 7 TIMER under power on or standby mode press this key to setup on off time from 1 24 8 SWING air flow after machine turns on press this key the louver will swing continuous...

Страница 8: ...elect cooling mode cooling mode indictor turns on Press UP or DOWN to adjust temperature from 16 to 31 Press SPEED to select high or low fan speed Fan mode Press MODE to select fan mode fan mode indicator turns on Press SPEED to select high speed or low speed Temperature and sleeping function cannot be setup Timer mode Under standby mode press TIMER to setup the power on time Timer indicator turns...

Страница 9: ...then keep the same Sleeping mode is invalid under dehumidifying and fan mode Under water full machine standby and mode conversion sleeping mode will be cancelled Compressor protection Three minutes later after power on restart compressor starts to run Water Drainage This machine with auto water evaporating system Condensed water cycle to cool down the condenser which will not only improve cooling ...

Страница 10: ...he filters every two weeks if filters are blocked by dust machine efficiency will be reduced Clean the filters in warm water with neutral detergent then dry the cleaned filters on a shady place Note Don t run the machine without filters Season Cleaning If the machine will be unused for a long time please do as following Pull out drainage plug to flow out water Let the machine runs under fan mode f...

Страница 11: ...e reduces Note when abnormal situations are occurred turn off machine and pull out plug then contact with professional electrician for help THE DISPOSAL OF ELECTRICAL AND ELECTRONIC EQUIPMENT WASTE PRODUCTS ON THE PART OF FINAL USERS IN THE EUROPEAN UNION This symbol on the product or on the container indicates that this product cannot be eliminated with the general waste The user is responsible f...

Страница 12: ...Directive 2004 108 EC Electromagnetic Compatibility Directive 2006 95 EC Electrical equipment designed for use within certain voltage limits Directive 2009 125 EC Ecodesign requirements for energy related products Directive 2011 65 EC Restriction of use of certain hazardous substances in electrical and electronic equipment Directive 2010 30 EU Labelling and standard product in formation of the con...

Отзывы: