the equipment being worked upon prior to any removal of sealed covers, etc. 

If it is absolutely necessary to have an electrical supply to equipment during servicing, 
then a permanently operating form of leak detection shall be located at the most critical 
point to warn of a potentially hazardous situation. 

Particular attention shall be paid to the following to ensure that by working on electrical 
components,  the  casing  is  not  altered  in  such  a  way  that  the  level  of  protection  is 
affected.  This  shall  include  damage  to  cables,  excessive  number  of  connections, 
terminals not made to original specification, damage to seals, incorrect fitting of glands, 
etc. 

Ensure that apparatus is mounted securely. 

Ensure that seals or sealing materials have not degraded such that they no longer 
serve the purpose of preventing the ingress of flammable atmospheres, Replacement 
parts shall be in accordance with the manufacturer’s specifications. 

NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak 
detection equipment. Intrinsically safe components do not have to be isolated prior to 
working on them. 

10.Repair to intrinsically safe components 

Do  not  apply  any  permanent  inductive  or  capacitance  loads  to  the  circuit  without 
ensuring that this will not exceed the permissible voltage and current permitted for the 
equipment in use. 

Intrinsically components are the only types that can be worked on while live in the 
presence of a flammable atmosphere. The test apparatus shall be at the correct rating. 

Replace components only with parts specified by the manufacturer. Other parts may 
result in the ignition of refrigerant in the atmosphere from a leak.

 

11.Cabling 

C

heck that cabling will not be subject to wear, corrosion, excessive pressure, vibration, 

sharp edges or any other adverse environmental effects. The check shall also take into 
account the effects of aging or continual vibration from sources such as compressors 
or fans. 

12.Leakage detection for flammable refrigerants   

Содержание DUE-1239

Страница 1: ...1 DEHUMIDIFIER DUE 1239 Owner s Manual READ THESE INSTRUCTIONS CAREFULLY BEFORE OPERATING THE APPLIANCE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Страница 2: ...ehumidifier is built to be compact and lightweight The casters on the bottom of the unit make it easy to move from room to room Low Temperature Operation with Automatic Defrost When the unit is runnin...

Страница 3: ...r supply cord is damaged it must be replaced by the manufacturer or a similarly qualified person in order to avoid a hazard 11 The appliance must be positioned so that the plug is accessible 12 Please...

Страница 4: ...al gas regulations Servicing shall be performed only as recommended by the manufacturer The appliance shall be stored so as to prevent mechanical damage from occurring Any person who is involved with...

Страница 5: ...cturer will take back the old appliance for disposal at least free of charge to the user 4 As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in...

Страница 6: ...a room temperature of 30 with a relative humidity of 80 If specifications are improved after this pointing the product nameplate will reflect the new specifications The operational temperature is in t...

Страница 7: ...7 PRODUCT DIAGRAM Parts 1 Air Outlet 2 Display Screen 3 Control Panel 4 Handle 5 Filter Box 6 Water Tank 7 POWER CORD 8 CASTER 9 Water Pipe...

Страница 8: ...urple When you turn on the unit the halo will be lighted If the environment humidity is higher than 70 it will show red color If the environment humidity is lower than 50 it will show purple color If...

Страница 9: ...f the machine is Dehumidifying mode 3 Press to set high or low fan speed The fan speed lamp will be turned on The fan speed can be adjusted under continuous mode and can also work automatically If the...

Страница 10: ...auto turn off after the setting time If the unit is turned on or off by operation or water full mode then the auto turn on off function will be canceled 6 Press the key to adjust the working mode the...

Страница 11: ...rty wash it with cold or lukewarm water Do not use any detergent scouring pads chemically treated dust cloths gasoline benzene thinner or other solvents as these can scratch and damage the tank and ca...

Страница 12: ...iate plate reach out from the side of the water tank install it in place and arrange the drain pipe The water in the drainage tank can be continuously drained out from the continuous port on the unit...

Страница 13: ...moothly and place the inlet grill into the right position Storing the Dehumidifier When the unit is not being used for a long period of time and you want to store it note the following steps 1 Empty a...

Страница 14: ...above 35 or below 5 The protection device is activated and the unit cannot be started The dehumidifying function doesn t work Is the air filter clogged Clean the air filter as instructed under Cleanin...

Страница 15: ...rior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerant i e no...

Страница 16: ...om size within which the refrigerant containing parts are installed the ventilation machinery and outlets are operating adequately and are not obstructed 8 Checks to electrical devices Repair and main...

Страница 17: ...the manufacturer s specifications NOTE The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior...

Страница 18: ...igerant and corrode the copper pipe work If a leak is suspected all naked flames shall be removed extinguished If a leak of refrigerant is found which requires brazing all of the refrigerant shall be...

Страница 19: ...o minimize the amount of refrigerant contained in them Cylinders shall be kept upright Ensure that the refrigeration system is earthed prior to charging the system with refrigerant Label the system wh...

Страница 20: ...oved from site promptly and all isolation valves on the equipment are closed off k Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked 1...

Страница 21: ...rigerants in recovery units and especially not in cylinders If compressors or compressor oils are to be removed ensure that they have been evacuated to an acceptable level to make certain that flammab...

Страница 22: ...here are separate collection systems for used electrical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY Herewith we state that this product com...

Отзывы: