UNITED DUE-1238 Скачать руководство пользователя страница 7

 

DRAINING INSTRUCTION 

Draining water can storage in the water tank, or be continuous drained 

by PVC tube. (The PVC tube is not included in the product.) 

USAGE OF WATER TANK 

When dehumidifying, the condensing water may be drained to water 

tank. And the unit will stop working with 

indicating light illuminates when the water tank is 

full of water, please pour out the water that time. 

1.  Take out the water tank as Fig 01 and pour 

out the water. 

2.  Put the water tank back. 

3.  Press power key to turn on the unit. 

CONTINUOUS DRAINAGE 

 

1.  Before continuous draining water, please 

take out the water tank and plug a draining 

tube to draining hole (See Fig 02.) Then put 

the water tank back.

 

2.  Draining tube should place lower than the 

draining hole to let water flow out. 

 

FILTER REMOVAL 

1.  Take out the water tank before remove the filter. 

2.  Pulling out the filter with handles of 

filter. 

3.  Wash the filter with cool water (cooler 

than 40

) every two weeks, and put 

filter back after it air-dried naturally. 

Fig 01

 

Fig 02

 

Содержание DUE-1238

Страница 1: ...DUE 1238 DEHUMIDIFIER USER MANUAL...

Страница 2: ...cleaning the product and also when the product is not in used 6 Please operate the product with specified electricity voltage 7 Please use this product only for household appliance and follow the des...

Страница 3: ...vision 12 Please keep the product from the wall or other barriers in a minimum distance of 50 cm 13 Please install the appliance following the country wiring laws OPERATING INSTRUCTION 1 Power Button...

Страница 4: ...uminate or extinguish 3 TIMER a Press the key to set time you need 1 to 24 hours b When setting timer in stand by mode the unit will be turned on automatically when setting timer in operating mode the...

Страница 5: ...a When ambient temperature is lower than 5 compressor will stop working b When ambient temperature is higher than 5 and lower than 20 the product will set the humidity to 60 automatically c When ambi...

Страница 6: ...umidifier shut down unreasonably please make sure whether the plug is connected firmly to power supply If the plug and power supply are in normal condition please wait for 10 minutes before restart th...

Страница 7: ...er tank as Fig 01 and pour out the water 2 Put the water tank back 3 Press power key to turn on the unit CONTINUOUS DRAINAGE 1 Before continuous draining water please take out the water tank and plug...

Страница 8: ...e unit to avoid the damage of the unit 3 Please disconnect the power cord to the power supply when you turn off the unit or intend to stop using for long time 4 In order to improve the performance of...

Страница 9: ...0W Rated Current 1 2A Weight 10 2Kg Moisture Removal 30 RH80 12 liters day Dimension mm 312Wx243D x417H Applicable temperature 5 32 Water Tank Capacity 1 6L CE N842 2006 R134a is a kind of fluorinated...

Страница 10: ...rical and electronic products Please help us to conserve the environment we live in DECLARATION OF CONFORMITY This product complies with the requirements of the directives EMC Directive 04 108 EC Low...

Отзывы: