United Technologies Interlogix IFS NS3550-8T-2S Скачать руководство пользователя страница 2

 

2

Copyright 

 

© 2014  United Technologies Corporation, Inc.  

Interlogix is part of UTC Building & Industrial Systems, a unit of 
United Technologies Corporation.  All rights reserved. 

Trademarks and patents 

 

The IFS NS3550-8T-2S and logo are trademarks of United 
Technologies. 

Other trade names used in this document may be trademarks or 
registered trademarks of the manufacturers or vendors of the 
respective products. 

Intended use 

 

Use this product only for the purpose it was designed for; refer to the 
data sheet and user documentation for details. For the latest product 
information, contact your local supplier or visit us online at 
www.interlogix.com. 

Manufacturer 

 

UTC Building & Industrial Systems, Inc.  
2955 Red Hill Avenue 
Costa Mesa, CA 92626-5923, USA  
EU authorized manufacturing representative: 
UTC Fire & Security B.V., Kelvinstraat 7,  
6003 DH Weert, The Netherlands 

Certification 

 

 

 

N4131 

FCC compliance 

 

This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 
accordance with the instruction manual, may cause harmful 
interference to radio communications. 
You are cautioned that any changes or modifications not expressly 
approved by the party responsible for compliance could void the 
user's authority to operate the equipment. 

ACMA compliance 

 Notice!

 This is a Class A product. In a domestic environment this 

product may cause radio interference in which case the user may be 
required to take adequate measures. 

Canada 

 

This Class A digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe A est conforme á la norme 
NMB-003du Canada.

 

European Union directives   

2004/108/EC (EMC Directive): 

Hereby,

 UTC Building & Industrial 

Systems, Inc.

 declares that this device is in compliance with the 

essential requirements and other relevant provisions of Directive 
2004/108/EC.

 

 

 

 

 

2002/96/EC (WEEE directive): 

Products marked with this symbol 

cannot be disposed of as unsorted municipal waste in the European 
Union. For proper recycling, return this product to your local supplier 
upon the purchase of equivalent new equipment, or dispose of it at 
designated collection points. For more information see: 
www.recyclethis.info.

 

Contact information 

 

For contact information see our Web site: 

www.interlogix.com

Contact support 

 

www.interlogix.com/customer support

 

Содержание Interlogix IFS NS3550-8T-2S

Страница 1: ...IFS NS3550 8T 2S Quick Installation Guide P N 1072772 REV A ISS 24JUN14...

Страница 2: ...generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications You are cautioned t...

Страница 3: ...Guide 1 TABLE OF CONTENTS 3 INTRODUCTION 4 Package Contents 4 Requirements 4 Wiring the Power Input 5 Starting Web Management 6 TROUBLESHOOTING 10 Resetting the IP address and Admin Password 10 Contac...

Страница 4: ...if possible retain the original carton and packaging material in case of a need to return the product for repair replacement Requirements Workstations of subscribers running Windows 98 ME NT4 0 2000 X...

Страница 5: ...s Please follow the steps below to insert the power wire 1 Insert positive negative DC power wires into contacts 1 and 2 for DC POWER 1 or 5 and 6 for DC POWER 2 2 Tighten the wire clamp screws to pre...

Страница 6: ...open sockets The user has to explicitly modify the browser setting to enable Java Applets to use network ports To configure the Industrial Managed Switch through an Ethernet connection make sure the...

Страница 7: ...192 168 0 100 2 When the following login screen appears please enter the default username admin with password admin or the username password you have changed via console to login to the main screen o...

Страница 8: ...s of the switch is changed the change will take effect immediately after you click on the Save button Therefore you need to use the new IP address to access the Web interface 3 For security reasons pl...

Страница 9: ...al Managed Switch and all its ports or monitor network conditions Via the Web Management the administrator can setup the Industrial Managed Switch by select the functions those listed in the Main Func...

Страница 10: ...the IP address to the default IP Address 192 168 0 100 or reset the password to default value press the hardware reset button at the front panel about 10 seconds After the device is rebooted you can l...

Страница 11: ...855 286 8889 Option 1 Order Services Option 2 Technical Support 1 855 662 8439 MobileView Option 1 Order Services Option 2 Technical Support By Mail UTC Building Industrial Systems 3211 Progress Driv...

Страница 12: ...om MobileView Tech Support MobileViewTS fs utc com EMEA Support By Phone 32 0 2 725 1120 By Mail EMEA Headquarters UTC Fire Security EMEA BVBA Europe Middle East Africa Kouterveldstraat 2 1831 Diegem...

Отзывы: