T-360
5–6
Figure 5.4 Air Cleaner, Oil Bath
Air Cleaner Body Service
The air cleaner body should be inspected each time the oil cup is serviced. If there is any sign of contaminant
buildup or plugging, the air cleaner body should be removed and back flushed.
At least once a year, or at regular engine service intervals, remove the entire air cleaner and perform the following
cleaning procedure:
1. Remove oil cup. Check and clean center tube.
WARNING
!
Do not use gasoline to clean air cleaner parts.
2. Pump solvent through the air outlet with sufficient force and volume to produce a hard, even stream out of
the bottom of the body assembly. Reverse flush until all foreign material is removed.
5.4.13
Engine Crankcase Breather
The engine uses a closed type breather with the breather line attached to the cylinder head cover (see
). It
is not necessary to disassemble valve style elements for cleaning. However, the bleed hole should be checked to
ensure it is free of obstruction. Check once a year or at every 4,000 hours maintenance interval, whichever comes first.
Figure 5.5 Engine Crankcase Breather
Air Inlet Hood
Air Cleaner Body
Cap Clamp
Inner Oil Cup
Gasket
Oil Cup
Screw
Breather Cover
Bleed Hole
Breather Valve
Breather Tube
Содержание Carrier Transicold 69UG15
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 36: ......
Страница 64: ......
Страница 66: ...T 360 6 2 Figure 6 2 Schematic Diagram PIDs prior to UG2019 62 11725 0...
Страница 67: ...6 3 T 360 Figure 6 3 Schematic High Voltage Circuitry PIDs prior to UG2019...
Страница 68: ...T 360 6 4 Figure 6 4 Schematic Diagram Legend PIDs UG2019 and Up 62 04233 00...
Страница 69: ...6 5 T 360 Figure 6 5 Schematic Diagram PIDs UG2019 and Up 62 04233 00...
Страница 70: ...T 360 6 6 Figure 6 6 Schematic High Voltage Circuitry 7 Wire Generator PID UG2019 62 04232 00...
Страница 71: ...6 7 T 360 Figure 6 7 Schematic High Voltage Circuitry 8 Wire Generator PIDs UG2020 and Up 62 04235 00...
Страница 72: ...T 360 6 8...
Страница 75: ......