T-360
4–8
4.7
HIGH VOLTAGE CIRCUIT
Electrical troubleshooting for high voltage control circuit
WARNING
!
Before proceeding with the troubleshooting, make sure to follow your company’s standard
safety procedures for working with electrical components.
ITEM
CHECKS
POTENTIAL CAUSE
Receptacle (R)
Check output voltage at Receptacle R (L1-
L2, L2-L3, L1-L3) (50Hz: 360 - 460 VAC,
and 60Hz: 400 - 500 VAC)
Faulty Receptacle (Replace)
High Voltage Wires (from Cir-
cuit Breaker to Receptacle)
Check if wires/terminals are connected
(Check Continuity for each leg)
Loose connections (Tighten)
Circuit Breaker (CB)
Test the output power from Circuit Breaker
CB (21-22, 22-23, 21-23)
Faulty Circuit Breaker (Replace),
Circuit Breaker (CB) is in the OFF
position
Verify Circuit Breaker (CB) is in the ON po-
sition
Test the input power to the Circuit Breaker
CB (11-12, 12-13, 11-13)
High Voltage Wires (from Pri-
mary and Boost Contactors to
Circuit Breaker, Voltage Con-
troller, Fuse Blocks, Genera-
tor, and Battery Charger)
Check if wires/terminals are connected
(Check Continuity for each leg)
Loose connections (Tighten)
Primary (P) or Boost (B) Con-
tactor
Visually verify Primary (P) or Boost (B)
Contactor is energized (wait 10-20 seconds
after start-up)
Faulty Contactor/Faulty Voltage
Controller/Faulty
Fuses/Faulty
Generator (Replace)
Test the output voltage from Primary (P) or
Boost (B) Contactor (L1-L2, L2-L3, L1-L3)
(50Hz: 360 - 460 VAC, and 60Hz: 400 - 500
VAC)
Test the input voltage to Primary (P) or
Boost (B) Contactor (T1-T2, T2-T3, T1-T3)
(300 - 600 VAC)
Test Voltage between terminals A1-A2 of
Contactors. Engaged contactor (Primary or
Boost) shall be supplied with ~24VDC; Dis-
engaged 0VDC.
if Not, check 24VDC circuit/Faulty
Voltage Controller (Replace)if Not,
check 24VDC circuit/Faulty Volt-
age Controller (Replace)
Содержание Carrier Transicold 69UG15
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 36: ......
Страница 64: ......
Страница 66: ...T 360 6 2 Figure 6 2 Schematic Diagram PIDs prior to UG2019 62 11725 0...
Страница 67: ...6 3 T 360 Figure 6 3 Schematic High Voltage Circuitry PIDs prior to UG2019...
Страница 68: ...T 360 6 4 Figure 6 4 Schematic Diagram Legend PIDs UG2019 and Up 62 04233 00...
Страница 69: ...6 5 T 360 Figure 6 5 Schematic Diagram PIDs UG2019 and Up 62 04233 00...
Страница 70: ...T 360 6 6 Figure 6 6 Schematic High Voltage Circuitry 7 Wire Generator PID UG2019 62 04232 00...
Страница 71: ...6 7 T 360 Figure 6 7 Schematic High Voltage Circuitry 8 Wire Generator PIDs UG2020 and Up 62 04235 00...
Страница 72: ...T 360 6 8...
Страница 75: ......