background image

-18-

It  is  recommended  that  your  heating  system  is  serviced  regularly  and  that  the  appropriate  Service  Interval 

Record is completed.

SERVICE PROVIDER

Before  completing  the  appropriate  Service  Record  below,  please  ensure  you  have  carried  out  the  service 

as  described  in  the  manufacturer’s  instructions.  Always  use  the  manufacturer's  specified  spare  part  when 

replacement is necessary.

Service Record

Service 01

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 03

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 05

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 07

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 02

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 04

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 06

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Service 08

 Date: _____________________

Engineer Name:

 ________________________________

License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________

Stove Inspected:          Chimney Swept:
Items Replaced:

 ________________________________

Notes

Содержание VOGELZANG VG2020

Страница 1: ...nstallation Could Void Your Warranty Certified to UL 1482 2011 R2015 and ULC S627 00 R2016 Mobile home approved U S ONLY U S Environmental Protection Agency Certified to comply with 2020 particulate e...

Страница 2: ...CONTACT MAY CAUSE SKIN BURNS DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED DO NOT BURN GARBAGE FLAMMABLE FLUID SUCH AS GASOLINE N...

Страница 3: ...to the top of the unit as shown using the 3 5 16 18 x 1 1 2 bolts 3 washers and 3 weld tabs provided in the parts box FIREBRICK CONFIGURATION Replace the Firebrick as shown in the illustration 5 16 1...

Страница 4: ...e the most time is spent and in the most spacious room possible Recall that wood stoves produce radiating heat the heat we feel when we are close to a wood stove A wood stove also functions by convect...

Страница 5: ...E 12 12 305 305 F 22 22 559 559 D B A C E F E D B A C E F E Slide the hose clamp over the aluminium flex pipe Then slide the flex pipe over the air intake tube of the stove Next tighten the hose clamp...

Страница 6: ...MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME SECURING APPLIANCE S ON A PEDESTAL TO THE FLOOR Use the designated holes to secure the unit to the floor SECURING APPLIANCE S WITH LEGS TO THE FLOO...

Страница 7: ...e into the room through appliance and chimney connector joints An uncontrollable burn or excessive temperature indicates an excessive draft CHIMNEY Your wood stove may be hooked up with a 6 factory bu...

Страница 8: ...as recommended by the manufacturer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation MASONRY CHIMNEY Ensure that a masonry chimney meet...

Страница 9: ...nd a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insula...

Страница 10: ...rain or snow also accelerates the drying time A good indicator of if the wood is ready to burn is to check the piece ends If cracks are radiating in all directions from the center then the wood shoul...

Страница 11: ...ling on it and close the door If the piece ignites within 90 seconds from the time it was placed into the stove your wood is correctly dried If ignition takes longer your wood is damp If your wood his...

Страница 12: ...t going up the chimney as lost energy Therefore efficiency calculated using the lower heating value of wood will be higher than the efficiency calculated using the higher heating value In the United S...

Страница 13: ...these gases is somewhere between 275 F and 500 F Below these temperatures the build up of creosote is promoted Above 500 F heat is wasted since a too large quantity is lost into the atmosphere TO PREV...

Страница 14: ...e sold The glass should be washed only when cold PAINT Only clean your stove with a dry soft cloth that will not harm the paint finish If the paint becomes scratched or damaged it is possible to give...

Страница 15: ...nt VG2020 BP 1 9 610960 Pedestal Weldment VG2020 BP 1 10 610925 Ashpan Housing VG2020 BL 1 11 610883 Leg Weldment VG2020 BL 4 12 25826 Hearth Plate 1 13 29216 Ash Pan 1 14 610927 Damper Slide Weld 1 1...

Страница 16: ...Description Qty 1 83788 Socket Head Screw 1 2 893062 Roller Sleeve 1 3 893156 Wooden Thru Handle 1 4 893164 Door Handle 1 5 891373 Door Hinge Pad Threaded 2 6 40880 Lg Square Cast Door 1 7 88066 Rope...

Страница 17: ...17 Notes...

Страница 18: ...18 Notes...

Страница 19: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...