1.  Fill hopper and clean burn pot.
2.  Press the “On/Off” button. Make sure the green light 

comes on.

3.  Adjust the feed rate to the desired setting by pressing 

the “Heat Level Advance” button.

If the fire doesn’t start in 12 minutes, press “On/Off”, wait 

a few minutes, clear the burn pot, and start the procedure 

again.

OPENING DOOR

CAUTION:

•  DO NOT OPERATE YOUR STOVE WITH THE 

VIEWING DOOR OPEN. THE AUGER WILL NOT 

FEED PELLETS UNDER THESE CIRCUMSTANCES 

AND A SAFETY CONCERN MAY ARISE FROM 

SPARKS OR FUMES ENTERING THE ROOM.

•  THE DOOR MUST BE CLOSED AND SEALED 

DURING OPERATION.

If the door is opened while the stove is in operation it 

must be closed within 30 seconds or the stove will shut 

down. If the stove shuts down push the “On/Off” button 

to re-start your stove. The stove will have to fully shut 

down and turn off before you will be able to restart the 

stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not 

come on until the stove’s heat exchanger warms up. This 

usually takes about 10 minutes from start-up.

IF STOVE RUNS OUT OF PELLETS

The fire goes out and the auger motor and blowers will 

run until the stove cools. This will take 30 minutes or 

longer depending on the heat remaining in the appliance. 

After the stove components stop running all lights on 

the display will go out and the two digit display will begin 

flashing “E3”

REFUELLING

WARNING:

•  KEEP HOPPER LID CLOSED AT ALL TIMES 

EXCEPT WHEN REFILLING.

•  DO NOT OVERFILL HOPPER.

CAUTION:

•  THE HOPPER AND STOVE TOP WILL BE HOT 

DURING OPERATION; THEREFORE, YOU 

SHOULD ALWAYS USE SOME TYPE OF HAND 

PROTECTION WHEN REFUELING YOUR STOVE. 

•  DO NOT TOUCH THE HOT SURFACES OF THE 

STOVE. EDUCATE ALL CHILDREN ON THE 

DANGERS OF A HIGH-TEMPERATURE STOVE. 

YOUNG CHILDREN SHOULD BE SUPERVISED 

WHEN THEY ARE IN THE SAME ROOM AS THE 

STOVE.

•  NEVER PLACE YOUR HAND NEAR THE AUGER 

WHILE THE STOVE IS IN OPERATION.

•  WE RECOMMEND THAT YOU NOT LET THE 

HOPPER DROP BELOW 1/4 FULL.

TAMPER WARNING

This wood heater has a manufacturer-set minimum low 

burn rate that must not be altered. It is against federal 

regulations to alter this setting or otherwise operate this 

wood heater in a manner inconsistent with operating 

instructions in this manual.

SHUTDOWN PROCEDURE

WARNING:

NEVER SHUT DOWN THIS UNIT BY UNPLUGGING 

IT FROM THE POWER SOURCE.

Turning your stove off is a matter of pressing the “POWER” 

button on the display board. The green light will turn back 

to red when the “POWER” button is pushed. The auger 

motor will stop, and the blowers will continue to operate 

until the internal firebox temperatures have fallen to a 

preset level.
1.  Your stove is equipped with a high temperature 

thermodisc. This unit has a manual reset thermodisc. 

This safety switch has two functions.

A.  To recognize an overheat situation in the stove and 

shut down the fuel feed or auger system.

B.  In case of a malfunctioning convection blower, the 

high-temperature thermodisc will automatically 

shut down the auger, preventing the stove from 

overheating.

NOTE: On some units, once tripped, like a circuit breaker, 

the reset button will have to be pushed before restarting 

your stove. On other units the thermodisc has no reset 

button and will reset itself once the stove has cooled. The 

manufacturer recommends that you call your dealer if 

OPERATION INSTRUCTIONS

Содержание US5522

Страница 1: ...re officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new...

Страница 2: ...ons burning wood pellet fuel this heater has been shown to deliver heat at a rate of 13 640 to 32 591 Btu hr This heater achieved a particulate emissions rate of 1 5 g hr when tested to method ASTM E...

Страница 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Страница 4: ...ory installed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the fa...

Страница 5: ...nto the damper rod DOOR HANDLE INSTALLATION 1 Slide one of the provided washers onto the door handle rod 2 Next slide the wood handle onto the door handle rod 3 Slide the other provided washer onto th...

Страница 6: ...TECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRON...

Страница 7: ...6 153 mm on each side and 1 26 mm behind the stove Floor protection must extend under and 2 51 mm to each side of the chimney tee for an interior vertical installation A Floor Protector of 1 26 mm th...

Страница 8: ...home transportable building with 8 GA copper wire using a serrated or star washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minim...

Страница 9: ...ned to disassemble for cleaning and should be checked several times during the burning season The pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLAT...

Страница 10: ...ause bodily harm heater damage and void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it...

Страница 11: ...ves We recommend a 3ft 0 91m minimum vertical rise on the inside or outside of the house The through the wall installation is the least expensive and simplest installation Never terminate the end vent...

Страница 12: ...AKE SURE TO KEEP IN MIND YOUR UNIT S CLEARANCE REQUIREMENTS 1 Mark the area and then cut the wall for vent installation if needed 2 Install the wall thimble as specified by the manufacturer wall thimb...

Страница 13: ...at range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled wi...

Страница 14: ...educed performance Store your pellets in a dry place DO NOT store the fuel within the installation clearances of the unit or within the space required for refuelling and ash removal Doing so could res...

Страница 15: ...ll minimize this Avoid placing items on the stovetop during this period because the paint could be affected Attempts to achieve heat output rates that exceed heater design specifications can result in...

Страница 16: ...HEREFORE YOU SHOULD ALWAYS USE SOME TYPE OF HAND PROTECTION WHEN REFUELING YOUR STOVE DO NOT TOUCH THE HOT SURFACES OF THE STOVE EDUCATE ALL CHILDREN ON THE DANGERS OF A HIGH TEMPERATURE STOVE YOUNG C...

Страница 17: ...move the clean outs and vacuum out any accumulated ash This should be done at least once per month or more frequently if large amounts of ash are noticed while cleaning or if the stove does not seem t...

Страница 18: ...rush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally...

Страница 19: ...gloves carefully remove any loose pieces of glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eigh...

Страница 20: ...himney venting for transportation of a transportable building The parts or materials to be employed for ember protectors and the minimum areas to be covered and their relation to the space heater as w...

Страница 21: ...le The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stov...

Страница 22: ...es to the air switch Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should...

Страница 23: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Страница 24: ...secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auge...

Страница 25: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Страница 26: ...in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing Next remove the two nuts that hol...

Страница 27: ...ent type of wood softwood vs hardwood Different woods have different characteristics when being burned High Limit Switch Keeps Tripping Possible Causes Possible Remedies Unplug stove first when possib...

Страница 28: ...28 2023 United States Stove Company WIRING DIAGRAM CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 29: ...bly 1 5 80780 IR Remote 1 6 80455 High Temp Snapdisc 1 7 80886 Control Board 1 8 88351 Channel Gasket 1 9 88118 Ignitor Flange Gasket 1 10 80869 Ceramic Ignitor 1 Key Part Description Qty 11 80549 Pre...

Страница 30: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Страница 31: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Страница 32: ...80455 Snapdisc temp rature lev e 1 7 80886 Assy de carte de circuit imprim 1 8 88351 Joint de canal 1 9 88118 Joint de bride d igniteur 1 10 80869 Ignitor c ramique 1 Cl Partie Description Qt 11 8054...

Страница 33: ...nited States Stove Company SCH MA DE C BLAGE CORRECT FAUX ASSUREZ VOUS QUE LES FILS SONT CONNECT S AUX DEUX BROCHES INF RIEURES DE L INTERRUPTEUR DE LA TR MIE COMME ILLUSTR 1 25A 250V Fusible 7 5A 250...

Страница 34: ...NT La marque ou le lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t q...

Страница 35: ...Retirez le moteur de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bl...

Страница 36: ...nt est d fectueux Le tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la...

Страница 37: ...u moteur de la tari re Utilisez un testeur de continuit pour tester l interrupteur de s curit de la tr mie remplacer le si n cessaire L arbre de la tari re est coinc Commencez par vider la tr mie Puis...

Страница 38: ...par vider la tr mie Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintena...

Страница 39: ...eur de d bit d air Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilate...

Страница 40: ...ble Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se pe...

Страница 41: ...ur le tampon de braises ne doit s tendre que jusqu la base du mur Un tampon de braises ne doit pas tre plac sur un tapis moins que le tampon ne soit structurellement soutenu pour emp cher le d placeme...

Страница 42: ...rait 1 Une fois le radiateur refroidi retirez la porte du radiateur 2 Retirez le joint de corde de la porte puis les crous retenant le dispositif de retenue du verre en place 3 Tout en portant des gan...

Страница 43: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Страница 44: ...mul es Cela devrait tre fait au moins une fois par mois ou plus fr quemment si de grandes quantit s de cendres sont remarqu es pendant le nettoyage ou si le po le ne semble pas br ler correctement Au...

Страница 45: ...VOS MAINS LORS DU REMPLISSAGE DU PO LE NE TOUCHEZ PAS AUX SURFACES CHAUDES DU PO LE ENSEIGNEZ AUX ENFANTS LES DANGERS DES PO LES HAUTE TEMP RATURE LES JEUNES ENFANTS DOIVENT TRE SURVEILL S LORSQU ILS...

Страница 46: ...tal Le maintien de petits incendies minimisera cela vitez de placer des articles sur la cuisini re pendant cette p riode car la peinture pourrait tre affect e Les tentatives pour atteindre des d bits...

Страница 47: ...s Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le plein et enlever les cendres Cela pourrait...

Страница 48: ...production ou la plage de chaleur du po le Les niveaux de production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche...

Страница 49: ...us les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette installation AVERTISSEMENT VOUS VOUDREZ PEUT TRE LOCALISER LES UTILITAIRES O...

Страница 50: ...pour obtenir au dessus de la ligne de cong re Cette m me installation peut tre utilis e si votre chauffe eau est en dessous du niveau du sol en ajoutant simplement la section de nettoyage et tuyau ver...

Страница 51: ...i pourrait causer des l sions corporelles les dommages de chauffage et annuler votre garantie ECHAPPEMENT HORIZONTALES INSTALLATION 1 Localisez votre po le granul s dans un endroit qui r pond aux exig...

Страница 52: ...t tre achet s par ment INSTALLATION D VENT GRANUL S L installation doit comprendre un t de nettoyage pour permettre la collecte des cendres volantes et pour permettre le nettoyage p riodique du syst m...

Страница 53: ...po PL et doit d passer d au moins 36 po 914 mm au dessus de la ligne de toit de la maisons mobiles b timents portatifs et doit tre install l aide d un coupe feu de plafond certifi et d un chapeau de...

Страница 54: ...t tre suffisamment grand pour s tendre sur au moins 6 po 153 mm l avant 6 po 153 mm de chaque c t et 1 po 26 mm derri re le po le La protection du plancher doit s tendre sous et 2 po 51 mm de chaque c...

Страница 55: ...RDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N...

Страница 56: ...re INSTALLATION DE LA POIGN E DE PORTE 1 Faites glisser l une des rondelles fournies sur la tige de la poign e de porte 2 Faites ensuite glisser la poign e en bois sur la tige de la poign e de porte 3...

Страница 57: ...ll s en usine sur le dessus du po le Il y aura deux faisceaux de c bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connec...

Страница 58: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Страница 59: ...x r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meilleurs r sultats Temps de combustion r glage...

Страница 60: ...mpromis de fortune lors de l installation de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans...

Отзывы: