IMPORTANCE OF PROPER DRAFT
Draft is a force that moves air from the appliance up
through the chimney. The amount of draft in your chimney
depends on the length of the chimney, local geography,
nearby obstructions and other factors. Too much draft
may cause excessive temperatures in the appliance. An
inadequate draft may cause back-puffing into the room
and “plugging” of the chimney. An inadequate draft
will cause the appliance to leak smoke into the room
through appliance and chimney connector joints. An
uncontrollable burn or excessive temperature indicates
an excessive draft.
CHIMNEY
Your wood stove may be hooked up with a 6” factory-
built or masonry chimney. If you are using a factory-
built chimney, it must comply with UL 103 or CSA-B365
standard; therefore it must be a Type HT (2100°F).
It must be installed according to the manufacturer’s
specifications. Take into account the chimney’s location
to ensure it is not too close to neighbors or in a valley which
may cause unhealthy or nuisance conditions. If you are
using a masonry chimney, it must be built in compliance
with the specifications of the National Building Code.
It must be lined with fire clay bricks, metal or clay tiles
sealed together with fire cement. Round flues are the
most efficient. The interior diameter of the chimney flue
must be identical to the stove smoke exhaust. A flue
which is too small may cause draft problems, while a large
flue favors rapid cooling of the gas, and hence the build-
up of creosote and the risk of chimney fires. Note that it
is the chimney and not the stove which creates the draft
effect; your stove’s performance is directly dependent on
an adequate draft from your chimney.
Do not connect
this unit to a chimney flue serving another appliance.
The following recommendations may be useful for the
installation of your chimney:
1. It must rise above the roof at least 3’ (0.9m) from the
uppermost point of contact.
2. The chimney must exceed any part of the building or
other obstruction within a 10’ (3.04m) distance by a
height of 2’ (0.6m).
3. The installation of an interior chimney is always
preferable to an exterior chimney. Indeed, the interior
chimney will, by definition, be hotter than an exterior
chimney, being heated up by the ambient air in the
house. Therefore the gas which circulates will cool
more slowly, thus reducing the build-up of creosote
and the risk of chimney fires.
4. The draft caused by the tendency for hot air to rise
will be increased with an interior chimney.
5. Using a fire screen at the extremity of the chimney
requires regular inspection to ensure that it is not
obstructed thus blocking the draft, and it should be
cleaned when used regularly.
FACTORY BUILT CHIMNEY
Listed Cap
Maintain 2”
Clearance
Listed
Chimney
Ceiling
Support
Ceiling
Support
Chimney
Connector
*
* Refer to Clearance
to Combustibles
Combustible Wall
Floor
Protector
To Stove
Storm Collar
Flashing
Listed
Chimney
Attic
Insulation
Sheild
Specified
Clearance
Chimney
Connector
Combustible
Ceiling Joists
To Stove
When a metal prefabricated chimney is used, the
manufacturer’s installation instructions must be