United States Stove GW7400 Скачать руководство пользователя страница 3

-

3

-

• 

IMPORTANT: Read this entire manual before installing 

and  operating  this  product.  Failure  to  do  so  may 

result  in  property  damage,  bodily  injury,  or  even 

death. Proper installation of this stove is crucial for 

safe and efficient operation.

• 

Contact  your  local  building  officials  or  authorities 

having jurisdiction to obtain a permit and information 

on any additional installation restrictions or inspection 

requirements in your area.

• 

Do  not  throw  this  manual  away.  This  manual  has 

important operating and maintenance instructions 

that you will need at a later time. Always follow the 

instructions in this manual.

• 

This appliance is designed for the use of pelletized 

fuel  that  meet  or  exceed  the  standard  set  by  the 

Pellet  Fuel  Institute(PFI).  The  use  of  other  fuels  will 

void warranty.

• 

This  appliance  is  a  freestanding  heater.  It  is  not 

intended to be attached to any type of ducting. It 

is not a furnace.

• 

HOT  WHILE  IN  OPERATION.  Do  not  touch  the  hot 

surfaces  of  the  stove.  Educate  all  children  on 

the  dangers  of  a  high-temperature  stove.  Young 

children should be supervised when they are in the 

same room as the stove.

• 

Never  use  gasoline,  gasoline-type  lantern  fuel, 

kerosene, charcoal  lighter  fluid,  or similar  liquids  to 

start or ‘freshen up’ a fire in this stove. Keep all such 

liquids well away from the stove while it is in use.

• 

Do not place clothing or other flammable items on 

or near this stove. 

• 

The fuel loading lid and stove top will be hot during 

operation;  therefore,  you  should  always  use  the 

provided  tool  or  some  type  of  hand  protection 

when refueling your stove. 

• 

WARNING! DO NOT INSTALL IN SLEEPING ROOM.

• 

THE  STRUCTURAL  INTEGRITY  OF  THE  MOBILE  HOME 

FLOOR,  WALL,  AND  CEILING/ROOF  MUST  BE 

MAINTAINED.

• 

A working smoke detector must be installed in the 

same room as this product.

• 

Install  vent  at  clearances  specified  by  the  vent 

manufacturer. 

• 

Do not connect the vent to a vent serving any other 

appliance or stove.

• 

Do not install a flue damper in the exhaust venting 

system of this unit.

• 

This  wood  heater  needs  periodic  inspection  and 

repair  for  proper  operation.  It  is  against  federal 

regulations to operate this wood heater in a manner 

inconsistent with operating instructions in this manual.

• 

Your  stove  requires  periodic  maintenance  and 

cleaning (see “MAINTENANCE”). Failure to maintain 

your  stove  may  lead  to  improper  and/or  unsafe 

operation.

• 

Allow  the  stove  to  cool  before  performing  any 

maintenance or cleaning. Ashes must be disposed 

in a steel container with a tight fitting lid, and moved 

outside immediately. The closed container of ashes 

should  be  placed  on  a  non-combustible  surface 

or  on  the  ground,  well  away  from  all  combustible 

materials, pending final disposal.

• 

Never try to repair or replace any part of the stove 

unless  instructions  for  doing  so  are  given  in  this 

manual. All other work should be done by a trained 

technician.

• 

The  exhaust  system  should  be  checked  monthly 

during the burning season for any build-up of soot 

or creosote. 

•  Use of outside air is required for Canadian installations 

on this unit, and may be used for tightly constructed 

homes in the USA. 

• 

Do  not  operate  your  stove  with  the  viewing  door 

open.  A  safety  concern  may  arise  from  sparks  or 

fumes entering the room.

• 

Never block free airflow through the open vents of 

the unit.

• 

Keep foreign objects out of the fuel chamber.

• 

This appliance is not intended for commercial use.

• 

Not intended for primary heat source.

• 

CARBON MONOXIDE (CO) HAZARD. A buildup of CO 

fumes is toxic and can be fatal. Carbon Monoxide is a 

colorless, odorless gas produced during combustion 

of  wood,  coal,  oil,  gas  and  by  other  fuel  burning 

appliances.  It  is  important  to  have  a  proper  draft 

and adequate replacement air ventilation so fumes 

are drawn out the chimney. Installed as instructed 

this stove is designed to be as safe as possible yet 

it is recommended to install a CO detector. Follow 

the  manufacturer’s  recommendations  for  proper 

installation  and  use.  It  is  recommended  to  be 

placed  at  table-top  level  (not  near  the  ceiling)  to 

avoid false alarms. Realize that devices other than 

a stove (i.e. motor exhaust) can trigger CO alarms.

• 

If alarm sounds:

• 

Recognize  the  symptoms  of  CO  poisoning 

(headaches, nausea & drowsiness).

• 

Increase ventilation (open windows & doors).

• 

Make sure stove doors and/or lids are closed and 

secured.

• 

Check stove for smoking or puffing (open airflow 

controls).

• 

Check  chimney  &  connector  pipe  for  leaks, 

blockage or down-draft conditions.

• 

Check CO device for false alarm.

Safety Precautions

Содержание GW7400

Страница 1: ...0 CALIFORNIA PROPOSITION 65 WARNING This product can expose you to chemicals including carbon monoxide which is known to the State of California to cause cancer birth defects and or other reproductive...

Страница 2: ...premium grade pellets that comply with Pellet Fuels Institute PFI standards Minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter length no greater than 1 5 not less than 8 200 BTU lb moisture u...

Страница 3: ...in a manner inconsistent with operating instructions in this manual Your stove requires periodic maintenance and cleaning see MAINTENANCE Failure to maintain your stove may lead to improper and or uns...

Страница 4: ...to the floor Option 2 Use the two brackets included with the unit to secure the appliance to the floor Slightly back the current bolts out of the rear of the unit Slide the bracket into place and bol...

Страница 5: ...OR PROTECTION EMBER PROTECTION This heater must have a non combustible floor protector ember protection installed beneath it if the floor is of combustible material If a floor pad is used it should be...

Страница 6: ...or excessive temperature indicates excessive draft Take into account the chimney s location to ensure it is not too close to neighbors or in a valley which may cause unhealthy or nuisance conditions...

Страница 7: ...aft levels For installation and operation instructions see the instructions included with the barometric draft regulator If you are unable to install a barometric draft regulator a limit plate can be...

Страница 8: ...ctly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect this unit to a chimney flue serving another appl...

Страница 9: ...bove the roof or other obstructions for safety and proper draft operation Never substitute alternative materials for any of the manufacturer s specified components or complete the install without usin...

Страница 10: ...which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimb...

Страница 11: ...tilation system is installed in the house Outside Air Connection 4FAK Installation If using outside combustion air you can purchase a standard 4FAK from your dealer and install it on the rear of the a...

Страница 12: ...unit is equipped with a secondary burn basket in the combustion chamber The basket can and will need to be agitated as needed The lever for agitating the basket is located on the lower left hand side...

Страница 13: ...oor must remain closed and sealed while the unit is being operated If the door is opened during operation it can cause unsafe burning conditions DO NOT refuel the unit if the fuel level is down to whe...

Страница 14: ...ors condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney c...

Страница 15: ...are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Other waste shall not be placed in this contai...

Страница 16: ...the paint becomes scratched or damaged it is possible to give your wood pellet stove a brand new look by repainting it with a 1200 F heat resistant paint that can be purchased from your dealer For thi...

Страница 17: ...r for assistance on repairing Possible leaks around the fire pot Visually inspect for damage or large cracks in the fire pot Leak in the upper burn chamber Excessive Pellets Dropping To The Burn Baske...

Страница 18: ...18 Replacement Parts 7 6 8 9 1 2 3 4 5 34 49 47 48 46 45 44 43 38 35 36 37 39 40 41 42 12 13 14 15 18 19 20 21 29 31 32 27 30 22 33 23 24 25 26 16 17 28 10 11...

Страница 19: ...urn Grate 1 27 28647 Ignition Flap 1 28 610906 Secondary Baffle Weldment 1 29 29162 Damper Shaker Basket Tool 1 30 29386 Right Shoulder 1 31 28964 Air Cover 1 32 28759 Air Slide 33 29387 Right Side Pa...

Страница 20: ...Head Screw 1 5 891372 Pad Door Hinge Threaded 2 6 40865 Viewing Door 1 7 88227 1 2 Overbraid Rope Gasket 4 3 ft 8 892965 Viewing Glass 1 9 28965 Air Wash Spacer 1 10 28721 Air Clamp 1 11 28722 Glass...

Страница 21: ...21 Notes...

Страница 22: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 23: ...nserver ce guide dans un endroit s r des fins de r f rence Lorsque vous nous crivez veuillez indiquer le num ro complet du mod le qui figure sur la plaque signal tique de l appareil de chauffage Lorsq...

Страница 24: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 25: ...5 891372 patin de porte charni re filet 2 6 40865 porte d observation 1 7 88227 Joint de corde 1 2 po 4 3 pi 8 892965 verre d observation 1 9 28965 Entretoise de lavage l air 1 10 28721 pince air 1 1...

Страница 26: ...re 1 17 28644 Retenue de brique 1 18 893063 Panneau sup rieur 1 19 83916 Ressort de rallonge 0 50 X 6 00 2 20 893066 Shaker Rod 1 21 892970 Panneau de base 2 22 28686 Cendrier 1 23 610905 Panier grave...

Страница 27: ...18 Pi ces De Rechange 7 6 8 9 1 2 3 4 5 34 49 47 48 46 45 44 43 38 35 36 37 39 40 41 42 12 13 14 15 18 19 20 21 29 31 32 27 30 22 33 23 24 25 26 16 17 28 10 11...

Страница 28: ...ur du pot feu Inspectez visuellement le radiateur pour d tecter la pr sence de dommages ou de grandes fissures dans le pot combustion Fuite d air dans la chambre de combustion sup rieure Chute excessi...

Страница 29: ...agera pas le fini Si la peinture devient gratign e ou endommag e il est possible de redonner une apparence neuve votre po le granules de bois en le repeignant avec une peinture r sistant une chaleur d...

Страница 30: ...but finale Si les cendres sont enterr es ou dispers es sur place elles doivent rester enferm es dans le r cipient jusqu ce qu elles soient compl tement refroidies Les autres d chets ne doivent pas tre...

Страница 31: ...ient d tre allum ou que le feu br le lentement Par cons quent les r sidus de cr osote s accumulent sur le rev tement du conduit de fum e Ce cr osote peut cr er un feu extr mement chaud lorsqu il est a...

Страница 32: ...devra tre agit p riodiquement afin de niveler le charbon Voici un bon exemple si le charbon s accumule pr s de la grille de combustion le panier devra tre agit REMARQUE Cet appareil n est pas muni d...

Страница 33: ...al E L appareil est muni d un deuxi me panier de combustion dans la chambre de combustion Il peut et devra tre agit au besoin Le levier d agitation du panier est situ sur le c t inf rieur gauche de l...

Страница 34: ...est pr sente sur les fen tres pendant l hiver 6 Un syst me de ventilation est install dans la maison CHAUFFAGE La combustion contr l e est la technique la plus efficace pour le br lage des granules de...

Страница 35: ...une section d une chemin e solid pak pr fabriqu e homologu e d au moins 304mm 12po avec un isolant de 25 4mm 1po ou plus et au diam tre interne de 203mm 8po 51mm 2po plus grand que le conduit de racco...

Страница 36: ...otection Association NFPA en demandant ce qu elle soit inspect e par un professionnel La chemin e ne doit pas comporter de fissures de mortier d tach ou d autres signes de d t rioration et d obstructi...

Страница 37: ...votre chemin e Les recommandations suivantes peuvent tre utiles l installation de votre chemin e 1 Ne branchez pas cette unit un conduit de fum e utilis par un autre appareil 2 Elle doit s lever au de...

Страница 38: ...instructions d installation et d utilisation voir les instructions fournies avec le r gulateur de tirage barom trique Si vous ne parvenez pas installer de r gulateur de tirage barom trique vous pouvez...

Страница 39: ...hemin e pour veiller ce qu elle ne soit pas trop pr s des voisins ou dans une vall e pouvant causer des conditions malsaines ou nuisibles CONDUIT DE RACCORDEMENT DE LA CHEMIN E CONDUITE DU PO LE Votre...

Страница 40: ...l avant et de 204 mm 8 po de chaque c t du radiateur La zone sous le parcours horizontal d un conduit de raccordement doit galement tre prot g e et s tendre au moins 50 8 mm 2 po au del des dimensions...

Страница 41: ...OU DE LIQUIDES SEMBLABLES POUR D MARRER OU RALLUMER LE FEU DANS CE RADIATEUR CONSERVEZ CES PRODUITS LOIN DU RADIATEUR LORSQUE CE DERNIER EST EN FONCTION EN CAS DE FEU DE CHEMIN E FERMEZ COMPL TEMENT L...

Страница 42: ...s consulter ENTRETIEN Le mauvais entretien de votre po le pourrait mener une op ration impropre ou non s curitaire Laissez le temps au po le de se refroidir avant de le nettoyer ou d effectuer son ent...

Страница 43: ...itute Une densit minimale de 640 7kg m3 40lb pi3 un diam tre entre 6mm et 7 9mm 1 4po et 5 16po une longueur inf rieure 38 1mm 1 5po une quantit minimale de 8200BTU lb une humidit inf rieure 8 du poid...

Страница 44: ...produire Pour votre s curit respectez les instructions d installation Ne faites jamais de compromis sur la qualit pendant l installation de ce radiateur Communiquez avec les responsables en b timent o...

Отзывы: