Attach the four(4) spring handles to the Feed/Ash Doors, 

Baffle Rod, and Shaker Rod by twisting the springs counter-

clockwise while applying pressure until you have screwed 

them approximately 3/4”-1” onto the rods.

(4) Spring Handles

DISTRIBUTION BLOWER & ACC.

(2) 

800 CFM Blower

(2) 

Gasket, Blower

(8) 

Tinnerman Clip, 1/4-20

(8) 

1/4-20 x 3/4 Bolt

(2) 

Conduit Assembly (5ft)

(1) 

Honeywell Limit Control

(1) 

Conduit Assembly (1ft)

(1) 

Junction Box

(1) 

Insulation (5” x 5”)

(1) 

Rocker Switch

(1) 

Romex Cable Clamp

(1) 

Fan Center Control

(3) 

73B Wire Nut

(1) 

74B Wire Nut

(1) 

Female Term. (blue)

(1) 

Female Term. (red)

(8) 

#10 x 1/2 Screw

1.  Remove all contents and insure that all components 

are present for assembly. See the part list below

2.  Begin  by  attaching  the  blowers  to  the  unit.  Insert  a 

clip into each mounting hole in the furnace’s cabinet 

back. Be sure to install the gasket between the blow

-

er and cabinet back. Insert the eight bolts provided 

and tighten. 

3.  Insert  the  adjustable  snap-disc  into  the  hole  in  the 

upper-left hand corner of the cabinet back. Attach 

using two of the #10 x 1/2 screws provided.

4.  Find the Snap-Disc box, the small black box shown on 

the left side in the illustration. Attach the shorter con

-

duit  assembly  to  the  bottom  of  the  box,  securing  it 

with the nut on the fitting.

5.  Plug  the  wires  onto  the  snap-disc  (see  wiring  sche

-

matic) and then attach the box to the back of the 

unit using four of the #10 x 1/2 screws provided.

6.  Next, mount the junction box and insulation using two 

of the #10 x 1/2 screws provided. Install the 5 x 5 insu

-

lation between the cabinet back and junction box, 

with the foil side to the cabinet back. Attach the con

-

duit assembly from the snap-disc box to the junction 

box as shown.

7.  If not already installed, snap the rocker switch into the 

top of the junction box.

8.  Attach the two longer conduit assemblies to the junc

-

tion box and to each blower.

9.  Provide a 110v power supply and secure it with the 

cable  clamp  to  the  right    side  of  the  box.  Make  all 

wire  connections  per  the  wiring  schematic  in  these 

instructions  using  the  supplied  hardware.  Mount  the 

junction box cover.

SPIN DAMPER

(1) Spin Draft

(1) 3/8-16 Carriage Bolt

(1) 3/8-16 Lock Nut

Screw the spin draft onto the 3/8” x 2-1/2” carriage bolt 

followed by the 3/8”-16 lock nut. Then screw the spin draft 

and  bolt  into the Combustion Air  Inlet allowing  approxi

-

mately 1/2” of the bolt to stick through into the threaded 

part of the tube. Secure the bolt in place with the 3/8”-16 

lock nut by tightening it against the tube bracket.

Содержание Clayton 1602M

Страница 1: ...80 www usstove com SAFETY NOTICE If this furnace is not properly installed a house fire may result For your safety follow these installation instructions Contact local building or fire officials about...

Страница 2: ...etting the draft adjustment and the chimney to which the unit is attached The actual area that this unit will heat depends on factors such as the conditions of the building heat loss type of construct...

Страница 3: ...d slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense in the rela tively cool chimney flue of a slow burning fire As a re...

Страница 4: ...m of 1 4 to the foot At no time should the pipe turn downward toward the chimney or run horizontal 2 There should be no more than two 90 degree elbows 3 The connector pipe should never be longer than...

Страница 5: ...order to insure proper furnace performance Failure to provide return air ducts of the specified size will void your warranty A filter should be installed in the cold air return Furnace fil ters shoul...

Страница 6: ...ting brackets on the left side of the door frames as illustrated The slots in the brack ets and latches are for door seal adjustment Make the proper adjustments then tighten the nuts The door s gas ke...

Страница 7: ...the illustration Attach the shorter con duit assembly to the bottom of the box securing it with the nut on the fitting 5 Plug the wires onto the snap disc see wiring sche matic and then attach the box...

Страница 8: ...CK REPLACEMENT If baffle replacement is necessary slide the baffle out until you can access the nuts thru the flue outlet Once the nuts have been removed slide the baffle off the rod and thru the open...

Страница 9: ...oal in on the shaker grates It should come up to about half of the first firebrick level Place crumpled paper over the coal and crisscross a couple handfuls of dry kindling wood 3 4 in thickness on to...

Страница 10: ...a fire extinguisher into the firebox After chimney fire is over completely inspect system for damage before further use NEVERthrowwateronthefireoratthefurnace asrapidly expanding steam could result in...

Страница 11: ...ap is not too close to the top of the chimney D Check chimney draft make sure chimney flue pipe is clean and chimney is of adequate height E Make sure you re not suffocating the fire with exces sive a...

Страница 12: ...12 USSC PARTS DIAGRAM 11 12 13 16 15 17 14 7 10 5 2 3 6 30 29 4 3 2 1 35 3 8 9 24 26 25 27 17 16 3 19 18 20 28 34 21 22 32 33 23 31...

Страница 13: ...ide x 9 tall x 1 1 4 thick 891414 3 18 Slide Baffle 24231 1 19 Baffle Rod 86603 1 20 Lock Nut 1 2 13 83444 2 21 Gasket Flue Collar 88032 1 22 Flue Collar 40246 1 23 Flue Collar Ring 22761 1 24 Smoke C...

Страница 14: ...for your home U S Stove offers the model UFB908 as an option and can be purchased from your local dealer The UFB908 utilizes a standard 16 x 20 filter that can be purchased from your local dealer or a...

Страница 15: ...al The installation is now ready to be plumbed to your exist ing hot water system Choose one of the three methods described in the Hot Water Coil instructions 6 Remove knockouts from the access panel...

Страница 16: ...method with the highest portion of your fire bed in the center of the firebox The first flames will be long and generally orange or yellow and produce quite a bit of smoke As the gases burn off the fl...

Страница 17: ...w minutes until the volatile gases have burned off It is not necessary to shake down the ashes each time you refuel the furnace Experience will be your best teacher BULLETIN RC454 A GUIDE TO BURNING C...

Страница 18: ...18 USSC NOTES...

Страница 19: ...19 USSC NOTES...

Страница 20: ...future reference When placing an order or for warranty claims please provide the following information found on the Certification Plate located below the ash door PART NUMBER PART DESCRIPTION MODEL NU...

Отзывы: