CONTROL PANEL
Turning the furnace OFF/ON, as well as adjustments for the fuel feed rate
and room fan speed are performed by pressing the appropriate button(s)
on the control panel which is located on the lower left-hand side of your
Breckwell
furnace.
This unit can operate in either automatic or manual mode. Automatic mode
has pre-set default settings.
Pressing the
“ON”
button on the control panel will begin the start-up
sequence for the furnace. Fuel will begin to feed through the auger feed
system after 3 minutes. Pressing and holding the “ON” button will rotate
the auger continuously until button is released, which feeds additional fuel.
Pressing the
“OFF”
button on the control panel will cause the furnace to
enter its shut-down sequence. The fuel feed system will stop pulling fuel
from the hopper and, once the
fi
re goes out and the furnace cools down,
the fans will stop running.
Pressing the
“Heat Range”
arrows, up or down, will adjust the amount of
fuel being delivered to the burnpot.
This unit comes preset from the factory to burn shelled corn. The display
will show a “
Cr
” in front of the heat setting. If burning only wood pellets, this
setting must be changed. To change, press and hold the heat range up and
down buttons simultaneously for approximately 2-3 seconds. The display
will change from “
Cr
” to “
Pr
”. If burning a pellet(50%) and corn(50%) mix,
the “
Cr
” setting will work the best for optimum performance.
The draft fan (exhaust) will come on as soon as the “ON” button is pressed. The fan will automatically adjust its speed
in accordance to the heat range setting. However, this speed can be manually operated by pressing the
“Draft Fan”
arrows up or down. “Draft Fan” when pressed, the display will show “Df-A”, which is automatic. Press the arrows again
to adjust fan speed. When the furnace is in the manual mode, the optional thermostat will not properly control the unit.
When adjusting the Draft Fan setting, try only 1 setting above or below the heat setting.
The room fan(s) will come on once the unit has reached operating temperature. The room fans will automatically adjust
their speed in accordance with the heat range setting. By pressing the
“Room Fan”
buttons, the display will show “Rf-
A” which is automatic or how many fans are running.
The
“Aux”
button is for Agitator operation. When the unit is “OFF”, pressing the “Aux” arrows will rotate the agitator
for easy removal for cleaning. The agitator, when in Automatic mode, will operate at set intervals. However, these can
be changed by pressing the arrows on the “Aux” button. The agitator can be adjusted from 0 to 9, setting “0” is off and
setting “9” is high.
The
“Auger Delay”
button can be used to pause rotation of the Auger and Agitator for approx. 1 minute. This can be
cancelled by pressing the “ON” button.
The
“Mode”
button is used to switch between manual and automatic mode. When in auto mode, the fans, auger, and
agitator will operate at preset intervals unless changed manually using the buttons mentioned above. When in manual
mode, the draft fan (exhaust) will operate at full speed (100%), so the air must be controlled with the damper just below
the viewing door.
During normal operation, this unit constantly monitors itself for potential problems. In the event of an error condition, the
unit will stop and an error code will be shown in the display. See the list of error codes found at the end of this manual.
Operation
RISK OF FIRE - DO NOT operate with fuel-loading or ash-removal doors open. DO NOT store fuel or
other combustible material within marked installation clearances. INSPECT and CLEAN
fl
ues and
chimneys REGULARLY.
WARNING