United States Stove Company LONGVIE DV12 Скачать руководство пользователя страница 5

USSC

5

VENTILATION INSTALLATION

The ventilation system consist of:

1_External Tube - Air incoming tube with enamel hood riveted in place.

1_Threaded Mounting Rod

1_Internal Tube - Outgoing flue gases

1_Adjusting Nut

Diagram Nº 3

Diagram Nº 4

For Model DV12:

Mark the three 5/16” (8mm) holes and drill

Insert the three plastic plugs provided in the previously drilled
holes.

Mark the hole for the 4-1/2” (11.5cm) dia. ventilation tube.
This must be rectilinear and with a slight fall towards the ex-
terior of approx. 2 degrees to avoid the entering of rain water.

Take into consideration the area indicated for the gas con-
nection.

The wall’s thickness cannot be less than 4-1/2” (11.5 cm) nor
can it exceed 13-1/2” (35cm). (See Diagram Nº 5) Tube lengths
and threaded mounting rod should be trimmed to comply to
the dimensions shown in Diagram Nº 3.

For Model DV20:

Mark the four(4) 5/16” (8mm) holes and drill

Insert the four(4) plastic plugs provided in the previously drilled
holes.

Mark the hole for the 6 1/4” (16cm) dia. ventilation tube.  This
must be rectilinear and with a slight fall towards the exterior
of approx. 2 degrees to avoid the entering of rain water.

Take into consideration the area indicated for the gas con-
nection.

The wall’s thickness cannot be less than 4-1/2” (11.5 cm) nor
can it exceed 13-1/2” (35cm). (See Diagram Nº 5) Tube lengths
and threaded mounting rod should be trimmed to comply to
the dimensions shown in Diagram Nº 4.

Final Assembly

Remove the front cover of the heater by removing the control
knob and the two(2) screws on the top of the cover.  Slide the
front upwards.

After tubes have been cut to length, slide the tubes and the
rod into position on the heater and adjust with the nut pro-
vided until you get a compact unit.

Slide the heater and ventilation assembly through the hole
until the heater reaches the wall. For the model DV12, se-
cure to the wall with the three(3) screws provided.  For the
model DV 20
, secure to the wall with the four(4) screws pro-
vided.

Check that hood protrudes the intended 4 1/4” (10.8 cm) from the exterior wall.

Seal any imperfections between wall and vent hood with putty, making sure that nothing falls inside the hood. (See
Diagram Nº 6)

A protection plate resistant to high temperatures is available at extra cost for use with external combustible walls. (See
Diagram Nº 7)

Содержание LONGVIE DV12

Страница 1: ...USSC 1...

Страница 2: ...ing peak pressures in the gas supply affecting normal combustion Its gas tight combustion chamber totally enameled avoids gases which are caused by combustion to contaminate the air and ensures a usef...

Страница 3: ...t air outlet Do not spill water over the heater as it may cause corrosion Allow heater to thoroughly cool before servicing Input ratings are shown in BTU per hour and are for elevations up to 2 000 fe...

Страница 4: ...4 USSC...

Страница 5: ...light fall towards the exterior of approx 2 degrees to avoid the entering of rain water Take into consideration the area indicated for the gas con nection The wall s thickness cannot be less than 4 1...

Страница 6: ...THE VENT AIR INTAKE SYSTEM MUST BE PROPERLY INSTALLED TO IN SURE PROPER AND SAFE OPERATION VENTILATION INSTALLATION continued Diagram N 7 Diagram N 6 IMPORTANT The appliance s vent cap should be at l...

Страница 7: ...12 inches 30 cm for appliance 10 000 BTU hr 3kW and 100 000 BTU hr 30 kW 36 inches 91 cm for appliance 100 000 BTU hr 30 kW 6 feet 1 83 m 7 feet 2 13 m 12 inches 30 cm 12 inches 30 cm 6 inches 15 cm f...

Страница 8: ...8 USSC VENTILATION INSTALLATION continued Diagram N 8...

Страница 9: ...he heater controls and burners Failure to do so could prevent the heater from operating reliably FIGURE 8 A qualified gas appliance installer must connect the heater to the gas supply Consult all loca...

Страница 10: ...t five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above on this page If you don t smell gas go to the next step Find the pilot by looking through the...

Страница 11: ...not on the valve side Remove the two 2 M4 screws that hold the pilot in place Clean with a vacuum cleaner or use a can of compressed air To Remove Burner Loosen the gas line from the burner on the ri...

Страница 12: ...er operation after servicing Permanently lubricated bearing system WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against sh...

Страница 13: ...USSC 13 DV20 REPAIR PARTS...

Страница 14: ...as Intake Fitting 1 15 1 15756 Gas Intake Lock Fitting 2 16 1 2466 Gas Fitting Support 1 17 1 2465 Control Insulation 1 18 1 Piezo Ignitor Nut 1 19 1 2463 Control Bracket 1 20 1 2464 Piezo Ignitor Bra...

Страница 15: ...USSC 15 DV12 REPAIR PARTS...

Страница 16: ...2 2462 Gas Fitting Support 1 14 2 2465 Control Insulation 1 15 2 Piezo Ignitor Nut 1 16 2 2463 Control Bracket 1 17 2 2464 Piezo Ignitor Bracket 1 18 2 12455 Piezo Ignitor 1 19 2 11699 Piezo Ignitor...

Страница 17: ...USSC 17 BURNER ASSEMBLY REPAIR PARTS...

Страница 18: ...zo Ignitor Cable 1 15 3 2468 Pilot Supply Tube 1 4 1 16 3 15707 5 16 Compression Sleeve 1 17 3 16322 Tube Nut 5 16 x G1 4 1 18 3 2467 Burner Supply Tube 3 8 dia 1 19 3 16364 5 16 Tube Fitting 1 20 3 1...

Страница 19: ...ses Tube DV20 Internal 1 2 4 2479 Air Incoming Tube DV20 External 1 3 4 347 Enameled Vent Cap DV20 1 4 4 2470 Connecting Rod 1 5 4 16371 Connecting Rod Nut 1 6 4 2475 Outgoing Flue Gases Tube DV12 Int...

Страница 20: ...al for future reference DV12 DV20 Owner s Manual When writing always give the full model number which is on the nameplate attached to the fireplace When ordering repair parts or options always give th...

Отзывы: