background image

USSC 

5

iNSTALLATiON OPTiONS

Read this entire manual before you install and use your Pellet

 

stove.  Failure to follow instructions may 

result in property damage, bodily injury, or even death!

(See specific installation details for clearances and other installation requirements)

Freestanding Unit

—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with 

clearance requirements for a freestanding stove installation.

An 

Alcove Unit

—supported by pedestal/legs and placed on a non-combustible floor surface in compliance with clearance 

requirements for an alcove installation.

Your 

King 

stove may be installed to code in either a 

conventional

 or 

mobile home 

(see SPECIAL MOBILE HOME 

REQUIREMENTS).

It is recommended that only a authorized technician install your 

King 

stove, preferably an NFI certified specialist.

Installation

iMPrOPEr iNSTALLATiON: 

The manufacturer will not be held responsible for damage caused by the malfunc

-

tion of a stove due to improper venting or installation. Call (800) 750-2723 and/or consult a professional installer 

if you have any questions.

FLOOr PrOTECTiON

This unit must be installed on a non-combustible floor surface.  If a floor pad is used, it should be UL listed or equal.  

The floor pad or non-combustible surface should be large enough to extend a minimum of 6-inches in front, 6-inches on 

each side, and 1-inch behind the stove (see FIGURE 1).  
Floor protection must extend under and 2-inches to each side of the chimney tee for an interior vertical installation (see 

FIGURE 2).
Your 

King 

stove will need a minimum 31” x 38” floor protector.

A Floor Protector of 1 inch thick is recommended for this installation.

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Содержание King

Страница 1: ...injury or even death Contact your local building or fire officials about restrictions and installation inspection requirements in your area Save these instructions Owner s Manual UNITED STATES STOVE C...

Страница 2: ...ecial Mobile Home Requirements 10 understanding your stove 11 control panel overview 12 Operation 13 15 Unit Preparation 13 Performing Initial Test 13 Performing a Dry Run 13 Start Up Procedure 14 Shu...

Страница 3: ...r fumes entering the room Allow the stove to cool before performing any maintenance or cleaning Ashes must be disposed in a metal container with a tight fitting lid The closed container of ashes shoul...

Страница 4: ...HZ 3 0 Amps Watts operational 175 approx Watts igniter running 425 approx Electrical Specifications FUEL CONSIDERATIONS Your Pellet stove is designed to burn premium hardwood pellets that comply with...

Страница 5: ...nician install your King stove preferably an NFI certified specialist Installation IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunc tion of a stove...

Страница 6: ...mum required clearance for suitable access to the control panel FIGURE 3 SIDEWALL CLEARANCES PARALLEL INSTALLATION FIGURE 4 SIDEWALL CLEARANCES CORNER INSTALLATION FIGURE 5 ALCOVE CLEARANCES PARALLEL...

Страница 7: ...12 feet or if the installation is over 2 500 feet above sea level We recommend the use of Simpson Dura Vent or Metal Fab pipe if you use other pipe consult your local building codes and or building in...

Страница 8: ...n adjacent to public walkways E Minimum 2 foot clearance above any grass plants or other combustible materials F Minimum 3 foot clearance from an forced air intake of any appliance G Minimum 2 foot cl...

Страница 9: ...by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass and leaves We recommend a 3 f...

Страница 10: ...your installation FIGURE 9 TYPICAL FRESH AIR TERMINATION FIGURE 8 EXHAUST INLET LOCATIONS Special Mobile Home Requirements WARNING Do not install in a sleeping room CAUTION The structural integrity o...

Страница 11: ...y the exhaust or draft fan must be maintained precisely Too little air will result in a flame that is non energetic or lazy If the fuel continues to flow with too little air for long enough the burn p...

Страница 12: ...eed will automatically be adjusted in accordance with the heat range setting By pressing the Room Fan up arrow you can adjust the fan speed setting up to Rf 9 The room fan must operate at a level grea...

Страница 13: ...ugr The auger motor is turned on full If the Auger Fuse is not blown and the fuse detection circuit is functioning the Heat Range LED will be lit and the other three top row LEDs will be off Hopper Sw...

Страница 14: ...is plugged into an outlet an outlet surge protector is highly recommended Fill the hopper with wood pellets do not allow any part of the bag or any other foreign material into the hopper as this may j...

Страница 15: ...re set limit the temperature limit control will automatically slow down the auger feed rate until the temperature returns to a normal condition Even though the heater will operate on the highest setti...

Страница 16: ...rt up Painted Surfaces Painted surfaces may be wiped down with a damp cloth If scratches appear or you wish to renew your paint contact your Authorized King Dealer to obtain a can of suitable high tem...

Страница 17: ...the exhaust system clean as needed Check that the pressure switch connection to the firebox is free of ash or clear of obstructions Auger system is jammed or there is a bridging of the fuel in the hop...

Страница 18: ...on or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat Range Display This indicates that the stove is in the norma...

Страница 19: ...USSC 19 Parts Diagram 11 3 2 1 5 6 4 7 9 8 10 12 Viewing Door Detail NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 20: ...29 31 1 31 891190 Bottom Bushing Plate 1 32 891180 Auger Cover 1 33 891161 Weld Bot Plate Retainer 1 34 891195 Bracket Drive Motor 1 35 891169 Hose Heater 3 in 36 80488 Drive Motor 1 37 83529 Hairpin...

Страница 21: ...USSC 21 Wiring Diagram GRAY BLACK NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 22: ...22 USSC Notes NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 23: ...USSC 23 Notes NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 24: ...ached to the heater When ordering repair parts always give the following infor mation as shown in this list 1 The part number 2 The part description 3 The model number 5510 4 The serial number _______...

Отзывы: