When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money 

by enabling you to solve simple problems yourself. Problems encountered are often the result of only five factors: 

1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You 

can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5.

For the sake of troubleshooting and using this guide to assist, you should look at your heat level setting to see 

which light is flashing.

•  Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” 

does not disconnect all power to the electrical components of the stove.

•  Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All 

other work should be done by a trained technician.

Display is Flashing “E1”

Possible Causes

Possible Remedies: (Unplug stove first when possible)

The convection blower is overheating and tripping the 

internal temperature shutoff.

Clean any dust off of the windings and fan blade. If oiling the 

blower does not help, the blower may be bad.

The stove is being left on the highest setting for extended 

periods of time.

If operating the heater on the highest heat setting, the room 

temperature could increase enough and lead to potential 

overheating situations. If this happens try operating at a lower 

heat setting.

Fuel other than wood pellets is being burned in the stove.

This pellet stove is designed and tested to use wood pellets. 

Check for signs of fuel other than wood pellets. No other 

types of fuel have been approved for this pellet stove. If there 

are signs of other types of fuel being used, stop using them 

immediately.

Power surge or brown out situation.

A power surge, spike, or voltage drop could cause the high 

limit switch to trip. Check to see if a surge protector is being 

used on the stove. If not, recommend one to the customer.

High Limit Switch is malfunctioning.

If the other items check out OK, replace the high limit switch.

Trouble Shooting Guide

Display is Flashing “E2”

Possible Causes

Possible Remedies: (Unplug stove first when possible)

Airflow switch hose or stove attachment pipes for hose are 

blocked.

Unhook air hose from the air switch and blow through it. If air 

flows freely, the hose and tube are fine. If air will not flow throw 

the hose, use a wire coat hanger to clear the blockage.

The air inlet, burnpot, interior combustion air chambers, 

combustion blower, or exhaust pipe are blocked with ash 

or foreign material.

Follow all cleaning procedures in the maintenance section of 

the owner’s manual.

The firebox is not properly sealed.

Make sure the door is closed and that the gasket is in good 

shape. 

Vent pipe is incorrectly installed.

Check to make sure vent pipe installation meets criteria in 

owner’s manual.

The airflow switch wire connections are bad.

Check the connectors that attach the gray wires to the air 

switch.

Combustion blower failure.

With the stove on, check to see if the combustion blower is 

running. If it is not, you will need to check for power going to 

the combustion blower. It should be a full current. If there is 

power, the blower is bad. If there is not, see #8.

Control board not sending power to combustion blower.

If there is no current going to the combustion blower, check all 

wire connections. If all wires are properly connected, you have 

a bad control board.

Control board not sending power to air switch.

There should be a 5-volt current (approximately) going to the 

air switch after the stove has been on for 30 seconds.

Содержание 5660

Страница 1: ...RY DUE TO PRODUCT ENHANCEMENT This unit is not intended to be used as a primary source of heat Certified to ASTM E1509 12 2017 and Certified to ULC S627 2000 U S Environmental Protection Agency Certif...

Страница 2: ...ll not feed pellets under these circumstances and a safety concern may arise from sparks or fumes entering the room Allow the stove to cool before performing any maintenance or cleaning Ashes must be...

Страница 3: ...ty per cubic feet 1 4 to 5 16 diameter length no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft...

Страница 4: ...alled on a combustible floor it is mandatory that a 1 2 13 mm thick non combustible hearth pad be installed under the heater The non combustible hearth pad must extend at least 6 152 mm beyond the fue...

Страница 5: ...ions PELLET VENT TYPE A certified 3 inch or 4 inch type PL pellet vent exhaust system must be used for installation and attached to the pipe connector provided on the back of the stove use a 3 inch to...

Страница 6: ...ance G Minimum 2 foot 0 61m clearance below eves or overhang H Minimum 1 foot 0 3m clearance horizontally from combustible wall I Must be a minimum of 3 foot 0 091m above the roof and 2 foot 0 61m abo...

Страница 7: ...nderneath the pellet stove This pad should extend at least 6 152 mm in front of the unit 3 Place the pellet stove approximately 15 381 mm away from the interior wall 4 Locate the center of the exhaust...

Страница 8: ...above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached With thi...

Страница 9: ...n into a mobile home HEARTH PAD FLOORING GROUND WIRE DIRECTLY TO METAL CHASSIS STEEL FRAME 1 4 LAG BOLTS SECURELY FASTENED Mobile Home Installation 69FAK OUTSIDE AIR SUPPLY OPTIONAL UNLESS INSTALLING...

Страница 10: ...button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled with a Thermostat Separate LEDs t...

Страница 11: ...a carefully prescribed rate Any additional fuel introduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke Do not burn wet pellet...

Страница 12: ...the fire to go out OPENING DOOR If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down If the stove shuts down push the On Off button to...

Страница 13: ...the exhaust system for any inspection cleaning or maintenance work Never perform any inspections cleaning or maintenance on a hot stove Do not operate stove with broken glass leakage of flue gas may...

Страница 14: ...re frequently if large amounts of ash are noticed while cleaning or if the stove does not seem to be burning properly If a vacuum is used to clean your stove we suggest using the AV15E AshVac vacuum T...

Страница 15: ...TS CLEAN ANNUALLY 1 Remove the front glass by releasing the two latches attaching it to the unit They are located behind the right side panel 2 Remove the two side brick panels 3 Remove the two interi...

Страница 16: ...th a damp cloth If scratches appear or you wish to renew your paint contact your authorized dealer to obtain a can of suitable high temperature paint GLASS CLEANING REMOVAL AND REPLACEMENT OF BROKEN D...

Страница 17: ...urn pot Daily Weekly Monthly or as needed Burn Pot Stirred Empty Combustion Chamber Brushed Ashes Check Empty Interior Chambers Vacuumed Combustion Blower Blades Vacuumed Brushed Convection Blower Vac...

Страница 18: ...the decorative logs in there correct location Your decorative logs should come in place however if this is not the case the following steps depicts the correct location STEP 2 Place log into correct p...

Страница 19: ...there are signs of other types of fuel being used stop using them immediately Power surge or brown out situation A power surge spike or voltage drop could cause the high limit switch to trip Check to...

Страница 20: ...e the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lowe...

Страница 21: ...Remove the auger motor from the auger shaft and try to run the unit If the motor will turn the shaft is jammed on something If the motor will not turn the motor is bad Display is Flashing E5 Possible...

Страница 22: ...motor will not turn the motor is bad Auger Jam Start by emptying the hopper Then remove the auger motor by removing the auger pin Remove the auger shaft inspection plate in the hopper so that you can...

Страница 23: ...HAS BLACK TIPS AFTER STOVE HAS BEEN ON FOR A WHILE THE BURNPOT OVERFILLS Possible Causes Possible Remedies Unplug stove first when possible Stove or vent pipe is dirty which restricts airflow through...

Страница 24: ...24 Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26...

Страница 25: ...Pot 1 7 88165 Brick Panel Right 1 8 88163 Brick Panel Center 1 9 88164 Brick Panel Left 1 10 891995 Magnet 4 11 891540 Latch Door 4 12 80491 Micro Switch 1 13 80676 PCB Circuit Board 1 14 892199 Hous...

Страница 26: ...26 Wiring Diagram CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 27: ...27 Notes...

Страница 28: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 29: ...ice fiable et efficace de votre appareil de chauffage et vous permettre de commander correctement les pi ces de rechange Conservez ce manuel dans un endroit s r pour r f rence future Lors de l criture...

Страница 30: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 31: ...R COMMUNICATIONS CABLE CONSEIL D AFFICHAGE Vue arri re BROWN GRIS BLEU ROSE PURPLE BLANC BLACK SOURCE DE COURANT 120 Volts AC BLACK BLANC ORANGE BLEU RED IGNITOR E1 ALARME DE SURCHAUFFE E2 VIDE ALARME...

Страница 32: ...stion 1 7 88165 Panneau de brique droite 1 8 88163 Panneau de brique centre 1 9 88164 Panneau de brique gauche 1 10 891995 Aimant 4 11 891540 Loquet de porte 4 12 80491 Micro interrupteur 1 13 80676 C...

Страница 33: ...24 Pi ces De Rechange 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26...

Страница 34: ...RAPIDEMENT FLAMME EST MOLLE DARK ET A TIPS NOIR APR S POELE A T SUR UN TOUT LA pot de combustion d borde Causes possibles Solutions possibles D branchez r chaud premier si possible Tuyau de po le ou d...

Страница 35: ...uses possibles Solutions possibles D branchez r chaud premier si possible Pressostat haute limite a d clench ou est d fectueux Attendez que le po le refroidir pendant environ 30 45 minutes Localisez l...

Страница 36: ...mauvais Affichage clignote E5 Causes possibles Solutions possibles D branchez r chaud premier si possible Le po le se d clenche automatiquement E5 lorsqu il est allum Le capteur T stat est venu sous f...

Страница 37: ...urt morceau de fil Ensuite branchez le po le back up Si le po le est en marche et fonctionne vous devez remplacer le thermodisque POF Ceci est pour tester seulement NE PAS LAISSER LE THERMODISQUE BYPA...

Страница 38: ...utres types de combustibles utilis s cesser de les utiliser imm diatement Surtension ou d une situation hors brun Une surtension pointe ou chute de tension pourrait provoquer la fin de course haute de...

Страница 39: ...les b ches d coratives leur emplacement correct Vos journaux d coratifs devraient venir en place si ce n est pas le cas les tapes ci dessous illustre l emplacement correct TAPE 2 Placez la b che dans...

Страница 40: ...tal 4 Vide pour liminer les cendres du foyer Remarque v rifiez que CENDRES SONT FROID AU TOUCHER AVANT ASPIRATION Certains aspirateurs peuvent fuir les cendres dans la pi ce Votre aspirateur devrait a...

Страница 41: ...nt tre essuy s avec un chiffon humide Si des rayures apparaissent ou si vous souhaitez renouveler votre peinture contactez votre revendeur agr pour obtenir une bo te de peinture appropri e haute temp...

Страница 42: ...NNUELLEMENT 1 Retirez la vitre avant en lib rant les deux loquets qui la fixent l unit Ils sont situ s derri re le panneau lat ral droit 2 Retirez les deux panneaux de brique lat rale 3 Retirez les de...

Страница 43: ...rateurs ordinaires c d Aspirateurs d atelier peuvent laisser fuir des cendres dans la pi ce NE PAS ASPIRER LES CENDRES CHAUDES NETTOYAGE Tubes d changeur thermique Votre po le granul s de chauffage de...

Страница 44: ...ui se combinent l humidit vacu e pour former la cr osote Les vapeurs de cr osote se condensent dans le conduit de chemin e relativement froid ou un feu qui vient de d marrer ou d un feu combustion len...

Страница 45: ...r de chaleur du po le se r chauffe Cela prend habituellement environ 10 minutes de start up SI PO LE MANQUE DE GRANULES Le feu teint et le moteur de la vis et les ventilateurs se d roulera jusqu ce qu...

Страница 46: ...able Pellets peuvent tre cribl s avant d tre plac dans la tr mie pour liminer la plupart des amendes 2 Reliures Certains granul s sont fabriqu s avec des mat riaux de tenir le ensemble ou lier eux 3 H...

Страница 47: ...u niveau 5 de chauffage C TOUCHE C F La touche C F fait passer l affichage deux chiffres des degr s Celsius aux degr s Fahrenheit et vice versa D TOUCHE MODE M T Le Mode de fonctionnement du po le peu...

Страница 48: ...ne maison mobile TAPIS CONDUCTEUR PLANCHER STRUCTURE EN ACIER FIL DE TERRE DIRECTEMENT AU CH SSIS M TALLIQUE TIRE FOND DE 1 4 BIEN SERR S 69FAK APPROVISIONNEMENT EN AIR EXT RIEUR EN OPTION En fonction...

Страница 49: ...oyage et tuyau vertical int rieur jusqu ce que le niveau du sol est atteint Avec cette installation vous devez tre conscient de la hauteur de la neige l herbe morte et les feuilles Nous recommandons u...

Страница 50: ...un tampon de foyer non combustible sous le po le granul s Ce coussin doit d passer d au moins 6 po 152 mm en face de l unit 3 Placez le po le granul s environ 15 po 381 mm de loin de la paroi int rieu...

Страница 51: ...mum 0 3 m 1 pieds d gagement au dessus d une porte ou fen tre qui ouvre C Le minimum de 0 9 m 3 pieds de d gagement de tout b timent adjacent D Le minimum de 2 13 m 7 pieds l autorisation de tout grad...

Страница 52: ...ns une vall e pouvant causer des conditions malsaines ou nuisibles PELLET TYPE D VENT Une liste UL de 3 pouces ou 4 pouces de type culot PL vent syst me d chappement doit tre utilis pour l installatio...

Страница 53: ...s des dommages au chauffage et annuler votre garantie CLOISON ARRI RE Alcove Dimensions 36 35 40 2 6 USA 6 CANADA 8 PROTECTION DE PLANCHER USA 6 CANADA 18 2 PROTECTION DE PLANCHER USA 6 CANADA 8 USA 6...

Страница 54: ...vec des granules de qualit sup rieure conformes aux normes du Pellet Fuels Institute PFI Vous ne pouvez br ler que des granules de qualit sup rieure dans ce po le granules densit minimale de 40 lb par...

Страница 55: ...a porte N essayez pas de faire fonctionner l unit avec une vitre cass e Une vitre de remplacement peut tre achet e chez votre revendeur U S Stove de chauffages pour pi ce carburant aux granul s N essa...

Страница 56: ...Cet appareil n est pas destin tre utilis en tant que principale source de chaleur U S Environmental Protection Agency Certifi aux normes d missions de 2020 particules United States Stove Company 227 I...

Отзывы: