background image

22 Ussc

NOTES

Содержание 2000

Страница 1: ...E SUPPLY CORD NEAR OR ACROSS HOT SURFACES Step 1 Fix the assembly to the back of the stove with the four screws provided Pedestal Trim Assembly Assemble trim pieces as shown with the screws provided i...

Страница 2: ...H AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will f...

Страница 3: ...alue k factor is given with a required thickness T in inches R 1 k x T C factor is given R 1 C Example If the floor protector is 4 brick with a C factor of 1 25 over 1 8 mineral board with a k factor...

Страница 4: ...must not pass through an attic or roof space closet or similar concealed space a floor or a ceiling For Canadian installations where passage through a wall or partition of combustible construction is...

Страница 5: ...nd of the section toward the chimney Any installation with a horizontal run of chimney pipe must conform to NFPA 211 You may contact NFPA National Fire Protection Association and request the latest ed...

Страница 6: ...the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connec...

Страница 7: ...same manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance t...

Страница 8: ...s sociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed...

Страница 9: ...chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm sep aration area contain...

Страница 10: ...there is combustion present 3 Opening a window slightly on a calm windless day alleviates any of the above symptoms 4 The house is equipped with a well sealed vapor barrier and tight fitting windows...

Страница 11: ...conditions it may rot instead of drying This point cannot be over stressed the vast majority of the problems related to the operation of a wood stove is caused by the fact that the wood used was too d...

Страница 12: ...nd the following burn procedures HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for each given situatio...

Страница 13: ...nse in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney connector...

Страница 14: ...riking or slamming shut Do not use the stove if the glass is broken If the glass on your stove breaks replace only with the glass supplied from your heater dealer Never substitute other materials for...

Страница 15: ...20 Ussc REPAIR PARTS 5 6 7 4 3 2 17 18 19 20 21 13 12 27 28 30 29 16 15 37 1 22 24 25 26 35 32 33 34 36 31 14 23 9 8 10 11 4 3 1 5 6 7 2 9 8 10 11 Feed Door Assembly...

Страница 16: ...8 Air Deflector 1 17 40292A Flue Collar 1 18 88032 Flue Collar Gasket 1 7 Ft 19 83432 5 16 18 x 1 1 2 Hex Head Bolt 3 20 83045 Washer 5 16 ID x 3 4 OD 3 21 83431 Weld Tab 3 22 89066 Firebrick 4 5 x 9...

Страница 17: ...22 Ussc NOTES...

Страница 18: ...Ussc 23 NOTES...

Страница 19: ...odel number which is on the nameplate attached to the heater when ordering repair parts always give the following infor mation as shown in this list 1 The part number 2 the part description 3 the mode...

Отзывы: