background image

 

P A N E L   D I S P L A Y S  

 

Содержание AD-2001

Страница 1: ...tile Full featured Easy to Program 2 way Listen in Verification Operates with all alarm systems Ideal stand alone dialer Provides reliable emergency notification 24 hours a day MODEL AD 2001 Automatic...

Страница 2: ...business requirement Plain English prompts walk the user through the process in a timely manner Programming options abound allowing the user to Store up to 4 telephone pager numbers Choose 1 9 callin...

Страница 3: ...mation Programming Recording OGMs Programming Channels Testing Your System Operating Your System Additional Features Programming Example Sample Program Planner Blank Program Planner Specifications Dia...

Страница 4: ...4 PANEL DISPLAYS...

Страница 5: ...5 Alarm Panel AD 2001 INSTALLATION HOOKUPS...

Страница 6: ...6 Stand Alone AD 2001 INSTALLATION HOOKUPS...

Страница 7: ...S Press these keys to enter telephone numbers and other programming information as specified in this manual A maximum of 50 digits can be input in each phone pager location CALLOUT FOR P Press this ke...

Страница 8: ...umbers will appear on the LCD as will the following key designations Press P one or more times in accordance with the number of seconds needed to accommodate the pager Remember each P provides a 2 sec...

Страница 9: ...ler will automatically exit this section Structuring Your Outgoing Messages The AD 2001 dialer was designed with optimum versatility and functionality in mind Nowhere is this more apparent than in the...

Страница 10: ...AD 2001 is designed to be adaptable to a complete range of personalized applications Each of the two input channels can be programmed individually for full system customization In addition to setting...

Страница 11: ...information and verify all elements of your system thoroughly before relying on the dialer to deliver the necessary information to the desired parties accurately and completely We strongly recommend t...

Страница 12: ...Each of the dialer s two channels can be activated by any of the following a normally open dry contact normally closed dry contact or positive 5 28VDC voltage activation Under a momentary activation a...

Страница 13: ...M S Press 2 three times to Scroll to option 4 press 1 to program in an ID message and two specific outgoing messages OGMs STEP 7 Using a prepared script and speaking six to eight inches from the diale...

Страница 14: ...this Program Planner in pencil initially After thoroughly testing your system redo your Program Planner in ink One copy should be kept in a safe place by the end user one copy should be retained by th...

Страница 15: ...tch LTS Low Temperature Switch CSS Cold Storage Switch WLS Water Level Sensor RTS Adjustable Temperature Controller N O N C PLS Power Loss Sensor 110VAC Sensors Magnetic Contacts Door and Window Glass...

Страница 16: ...M and 4 00 PM PST Monday through Friday Federal Communications Commission Radio And Television Interference Statement For A Class B Device This equipment generates and uses radio frequency energy and...

Отзывы: