7.3 Self-Monitoring and Recovery (Auto Restart)  

When a charging session is interrupted due to a temporary error condition, it will 
automatically restart charging when the cause of the temporary error condition returns to 
normal.  The status indicator lights remain flashing RED, with the number of flashes indicating 
the error condition,  until the error condition is resolved. 
•  All error conditions are able to Self-Recover if the error condition is cleared. 
•  The charging session will be stopped when the error condition occurs. The charger 

will self-monitor the error condition. If the error condition is cleared the charger will 
automatically reset in 60 seconds.  If the error condition is not cleared the charger will 
continue to display a RED error light.

•  If the  error condition occurs within 5 seconds of the start of a charging session a 

permanent fault will trigger. 

7.4 Reset Charger

In the instance of a permanent fault, or if the charger is not able to auto-recover,  it is 

recommended to perform a reset: 

1.  Count the number of flashes to identify the error type. 
2.  Unplug the charging Connector from your EV. 
3.  Turn off the power to the Charging Station by switching the upstream circuit breaker to 

the “OFF” position. 

4.  With the circuit breaker in the “OFF” position, wait 1-2 minutes and then switch the 

upstream circuit breaker back to the “ON” position 

5.  Confirm the Fault light is no longer present.  
6.  If the Fault light remains, please contact United Chargers. Fill out the 

Technical Support 

Form

. Indicate the number of red flashes. 

Содержание Grizzl-E Classic

Страница 1: ...GRIZZL E EV Charger User Manual Installation Guide...

Страница 2: ...nual Revision 2 5 Model Numbers Grizzl E Classic GR1 6 18 R GR1 6 24 R GR1 6 24 P GR1 14 18 R GR1 14 24 R GR1 14 24 P Grizzl E Avalanche Edition GR1 14 24 AB GR1 6 24 AB GR1 14 24 AW Grizzl E Special...

Страница 3: ...the Grizzl E Electric Vehicle Supply Equipment EVSE Before installing or using the EVSE read this document including any WARNING and CAUTION symbols The Symbols Used Have the Following Meanings Warni...

Страница 4: ...nsion cord or electrical adapter Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a licensed electrician if you are in doubt as to whether the...

Страница 5: ...edicated Circuit as follows 50A Circuit Rating To support 40A 9 6kW Maximum Charging Station Output 40A Circuit Rating To support 32A 7 68kW Maximum Charging Station Output 30A Circuit Rating To suppo...

Страница 6: ...or use with 20A Circuit Rating Charge Cable Length 18 ft 5 5m for GR1 6 18 XX and GR1 14 18 XX 24 ft 7 2m for GR1 6 24 XX and GR1 14 24 XX Electrical Circuit Input Power Requirements Dedicated 208VAC...

Страница 7: ...Tools Parts Required for Installation 14 4 2 Install the Charging Station 15 5 Wiring Connection 18 5 1 Optional Hardwire Connection 18 5 2 Replace Output Cable 20 6 EasyEvPlug Holster and Cable Manag...

Страница 8: ...8 1 Introduction Unpacking 1 1 Your Charger Charger Components 1 Input Cable NEMA 14 50P or NEMA 6 50 2 Output Cable J1772 Connector 3 Latch Release Button 4 Indicator Light 1 4 2 3...

Страница 9: ...9 Mounting Bracket x1 Security Pin x1 Front Plate Screw x4 Back Plate Screws x2 Holster x1 Holster Anchor x4 Holster Screws x4 1 2 Package Contents Mounting Kit EasyEvPlug Holster...

Страница 10: ...tory Setting a DEDICATED CIRCUIT rated for 40A 208VAC Single Phase or 240VAC Split Phase 50 60 Hz 24A Maximum Output Setting Default Factory Setting a DEDICATED CIRCUIT rated for 30A 208VAC Single Pha...

Страница 11: ...ut Setting is 40A 9 6 kW for use with a 50A Circuit Rating The Circuit must be a DEDICATED CIRCUIT 208VAC Single Phase or 240VAC Split Phase Requirements govern that only 80 of the circuit rated load...

Страница 12: ...ition switch on the main circuit board located directly to the left of the LED DOWN UP UP UP WARNING Do not touch live electrical parts Disconnect the power supply to the charging station before adjus...

Страница 13: ...m Current Output Factory Default Setting UP UP UP DOWN 32A Maximum Current Output UP DOWN UP DOWN 24A Maximum Current Output UP UP DOWN DOWN 16A Maximum Current Output UP DOWN DOWN DOWN 5 Once the DIP...

Страница 14: ...n 255 x 48 x 36 mm 14 8 1 1 4 8 5 16 x 1 2 PH3 5 32 Included with Product Included with Product Included with Product Included with Product Included with Product Included with Product Commercially Ava...

Страница 15: ...e mounting bracket by pushing down on the notch Front Piece Back Piece 2 Attach the front piece of the mounting bracket to the back of the charging station using the Front Plate screws Ensure the top...

Страница 16: ...ew Recommendations For finished walls supported by wood studs use 14 or M6 tapping screws Included For masonry walls use M6 mechanical screws Commercially available Use following torque force Screw To...

Страница 17: ...the front piece of the mounting bracket to the back piece of the mounting bracket 5 Secure the charger in place by inserting either the security pin or the outdoor security lock into the mounting brac...

Страница 18: ...the 4 screws at each corner of the charging station 4 Loosen the plastic cable gland beneath the charger 5 Loosen strain relief clamp on inside of charger Use a screwdriver or other tool to break and...

Страница 19: ...protection in accordance with the National Electrical Code ANSI NFPA 70 and the Canadian Electrical Code Part I C22 1 8 Once the input wiring and conduit are connected reassemble the charging station...

Страница 20: ...l wires through the Cable Gland and into the enclosure Feed the Input Cable through the enclosure such that of the black rubber jacket is exposed 7 Place metal strain relief clamp through terminal wir...

Страница 21: ...al angle for less wall clearance Integrated cable management holds up to 25 feet of cable The EasyEvPlug holster can be installed at any location near the charging station 1 Hold back of holster again...

Страница 22: ...o current consumed by the car Buzzer beeps Red Flashing Fault 7 2 LED Fault Indicator The number of red flashes indicates the type of fault LED Indicator of Flashes Error Description Red Flashing 1 Lo...

Страница 23: ...he error condition is not cleared the charger will continue to display a RED error light If the error condition occurs within 5 seconds of the start of a charging session a permanent fault will trigge...

Страница 24: ...nsure the connector is fully seated locked in place Once complete the charging session will begin 8 2 Stop Charging 1 Press down on the latch release button Ensure latch release button is fully compre...

Страница 25: ...the enclosure cannot be guaranteed if the charger is mounted upside down Ensure the charging connector is put back in the holster after charging to avoid damage Ensure the power cable is stored on the...

Страница 26: ...not include normal tear and wear Plugs that have been exposed to snow or water for a prolonged period of time are not covered by this warranty The waterproof rating of the enclosure cannot be guarante...

Отзывы: