23
7.3 Self-Monitoring and Recovery (Auto Restart)
When a charging session is interrupted due to a temporary error condition, it will
automatically restart charging when the cause of the temporary error condition returns to
normal. The status indicator lights remain flashing RED, with the number of flashes indicating
the error condition, until the error condition is resolved.
• All error conditions are able to Self-Recover if the error condition is cleared.
• The charging session will be stopped when the error condition occurs. The charger
will self-monitor the error condition. If the error condition is cleared the charger will
automatically reset in 60 seconds. If the error condition is not cleared the charger will
continue to display a RED error light.
• If the error condition occurs within 5 seconds of the start of a charging session a
permanent fault will trigger.
7.4 Reset Charger
In the instance of a permanent fault, or if the charger is not able to auto-recover, it is
recommended to perform a reset:
1. Count the number of flashes to identify the error type.
2. Unplug the charging Connector from your EV.
3. Turn off the power to the Charging Station by switching the upstream circuit breaker to
the “OFF” position.
4. With the circuit breaker in the “OFF” position, wait 1-2 minutes and then switch the
upstream circuit breaker back to the “ON” position
5. Confirm the Fault light is no longer present.
6. If the Fault light remains, please contact United Chargers. Fill out the
. Indicate the number of red flashes.